Back to search results

Continuous measurement of temperature in the industrial area

Back to search results
Continuous measurement of temperature in the industrial area
Appointment: the continuous measurement system allows for continuous measurement of the heating temperature of the industrial bucket, to improve the stability and reliability of measuring the temperature of liquid metal. Due to the fixed measurement position, the system eliminates errors due to the human factor. This method of measuring temperature was researched and invented on the theory of an absolutely black body. The principle of the temperature measurement system is the immersion of a temperature probe into molten steel to determine the temperature. The temperature probe made of an absolutely black body is designed in a special way to receive an infrared radiation signal corresponding to the temperature of molten steel.
Scope of application: Intermediate bucket
Measuring range:
Warming up the promkovsh: from 800°C to 1400°C; Molten steel: from 1400°C to 1600°C
Accuracy: Preheating of the promkovsh 7 ° C; Molten steel: 3 ° C
Response time: Hot response time 75 sec;
Cold response time 4 min
Measuring probe length: 964mm, 1100mm
Durability of measuring probes: 12 hours, 24 hours, 48 hours
Number of thermal shocks: up to 5 times
Reviews
There are no entries.