Search

3937 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Areas of use
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 41
    By name of foreign product
    Loading...
  • 550
    Item names
    Loading...
  • 3937
    Russian analogue
    Loading...
  • 24
    Areas of use
    Loading...
  • 132
    Manufacturer
    Loading...
View:
3937 products
Laboratory table of Classic LAB series
Laboratory table of Classic LAB series
1 supp.
Laboratory tables of Classic LAB series are based on a strong metal frame covered with chemically resistant paint, which is adjustable in height from 650 to 900 mm and can withstand a load of up to 300 kg. The material of the countertops can be selected based on the tasks set.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Workplace of Classic series
Workplace of Classic series
1 supp.
When lining up, Classic series desktops fit snugly together, without forming cracks and gaps. The universal design of the table frame allows you to further equip the workplace with a suspended pedestal and other necessary equipment. Additionally, work tables of Classic series can be equipped with a number of modules: electrical and perforated panels, overhead and local lighting, shelves for equipment, hanging cabinets, corner tables, etc.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Liquid chromatograph "Lumachrom-M"
Liquid chromatograph "Lumachrom-M"
1 supp.
The liquid chromatograph "Lumachrom-M" provides maximum automation of the analysis. The device is controlled using specialized software, which in combination with the continuous eluent supply mode and the autosampler gives the maximum level of autonomy of operation. In addition, such a solution minimizes labor costs and the influence of the human factor. The unique design solutions of the chromatograph provide continuous pulsation-free flow of the mobile phase in both isocratic and gradient modes, as well as the ability to work with any column sizes. Thanks to the improved technical characteristics on the Lumachrom-M device, it is possible to implement a wider list of techniques and GOST compared to previous models.
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Thermoreactor laboratory "TERMION"
Thermoreactor laboratory "TERMION"
1 supp.
Technical specifications: Operating temperature range, °C 50 ... 175 The discreteness of the temperature setting, °C 0.1 Temperature setting accuracy, °C ± 2 Accuracy of temperature maintenance, °C ± 0.5 Time interval setting range from 1 min to 20 h 59 min Time setting discreteness, min 1 Power consumption, V * A, no more than 450 The size of the landing nest (diameter x depth), mm 17 x 72 Number of landing nests, pcs 29 Overall dimensions, mm, not more than 300 x 300 x 120 Weight, kg, not more than 8
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Atomic absorption spectrometer "MGA-1000"
Atomic absorption spectrometer "MGA-1000"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 900 Spectral resolution, nm, no more: - in the range from 190 to 600 nm inclusive - in the range over 600 to 900 nm inclusive 2 3 Limit of detection of manganese, pg, no more than 3 Nickel detection limit, pg, no more than 20 The time of setting the operating mode of the spectrometers, min, no more than 15 The time of continuous operation of the spectrometers, h, no less than 8 The spectrometers are powered by a three-phase alternating current network: - rated supply voltage, V - frequency, Hz 380 (50 ±1) Overall dimensions of the spectrometer, mm, no more than 800 x 475 x 310 Mass of the spectrometer, kg, no more than 50 Power consumed by spectrometers, kV * A, no more: - in standby modes and settings of analytical parameters - in atomization and purification modes 0.1 6 Average time to failure, h, not less than 4000
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory Table of Gamma LAB Series
Laboratory Table of Gamma LAB Series
1 supp.
The laboratory tables are based on a strong metal frame covered with chemically resistant paint, which is adjustable in height from 740 to 860 mm and can withstand a load of up to 200 kg. The material of the countertops can be selected based on the tasks set. The tables in a standard set have a main shelf made of chipboard or plastic (HPL, HPL PLUS) and a socket block built into the right or left panel (5 sockets with grounding, 1 socket without grounding, a switch-off button), the main LED lighting is built into the upper horizontal bracket.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
PCU-1 Laboratory catalytic unit
PCU-1 Laboratory catalytic unit
The PCU-1 laboratory catalytic unit is designed to perform the following tasks: 1. Educational and scientific research of chemical processes; 2. Improvement of current industrial processes and development of new ones; 3. Studies of homogeneous and heterogeneous catalysts. The PCU-1 laboratory catalytic unit is manufactured in accordance with the technical requirements of customers so as to correspond to a wide range of technological parameters. Additionally, embedded equipment is designed to control the flow of raw materials and products, as well as data collection and processing. The unit can be subsequently modernized for new purposes. Main advantages: 1. A reliable and high-precision system of control and regulation of technological parameters; 2. Easy replacement of catalyst samples; 3. The possibility of conducting long-term tests in continuous mode; 4. The possibility of upgrading the unit for new purposes; 5. The possibility of conducting tests in flow and flow-circulation modes; 6. Control and accurate reproduction.
Produced in: Rostov region, Novocherkassk
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
1 supp.
Technical specifications: Frequency of the generated magnetron radiation, MHz 2450 ±50 Number of simultaneously decomposed samples 1 The maximum volume of the processed sample, cm3 50 Maximum working pressure in the container, atm 9 Power consumption, V*A 600 The average absorbed power (W) in the reactor when heating 30 cm3 of distilled water at 100% output power level of the magnetron in the range of supply voltage from 187 to 242 V 150... 250 Average time to failure, h, not less than 2500 Average service life, years, at least 5 Overall dimensions, mm, no more than 500x450x150 Weight, kg, no more than 22
Lumeks
Saint Petersburg
Produced in: Saint Petersburg