Search

4008 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 525
    Names
    Loading...
  • 131
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
4008 products
POZIS CHEMISTRY CH 41 Tablet press
POZIS CHEMISTRY CH 41 Tablet press
Productivity, thousand tab./hour 209 Number of stations 41 Max. pressing force, tn 10 Number of threads 2 Diameter of tablets, mm 6-20 Height of tablets, mm 1.5-9 Matrix filling depth, mm 18 Rotor material steel 40x13 Filling hopper capacity, l 20(30) Stepless rotor speed change The change in the speed of rotation of the feeder is independent Supply voltage 380V, 50Hz Power consumption, kW/hour 4.18 Weight, kg 2200 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Holder THERMOTEST-D2-16/20
Holder THERMOTEST-D2-16/20
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm. It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
Produced in: Tomsk
Vacuum tube MiniMed with sodium citrate 3.8%, 2.7 ml,13*75 mm, blue, glass, pack.100 pcs
Vacuum tube MiniMed with sodium citrate 3.8%, 2.7 ml,13*75 mm, blue, glass, pack.100 pcs
from 1 284 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Contact thermometer TK-5.01PS
Contact thermometer TK-5.01PS
from 14 904 ₽
The digital contact thermometer TK-5.01PS is designed to measure the surface temperature of solids by direct contact of the probe with the measuring object. The digital contact thermometer consists of an electronic unit and a non-replaceable surface probe. Thermoelectric converters (TP) with NSH according to GOST R 8.585 are used as a thermosensitive element in the probe.
POWDIX 600 X-ray powder diffractometer
POWDIX 600 X-ray powder diffractometer
A feature of the POWDIX 600 X-ray diffractometer scheme is the vertical Bragg-Brentano optical scheme with a fixed horizontal sample position, which makes working with powdery materials, gels and other viscous substances more practical and convenient. The high detector resolution and precise positioning of the POWDIX 600 X-ray goniometer achieve an accuracy better than +/- 0.02° (2θ) over the entire angular range. In the POWDIX 600 diffractometer, the X-ray tube is cooled by an integrated closed water circuit, which can be serviced by any laboratory employee. A wide variety of sample holders (holder for massive samples, holder with rotation, phoneless cuvettes) expands the functionality of the POWDIX 600 and makes it an invaluable tool for scientific research in solid-state physics, materials science, chemistry, geology and other fields of science The diffractometer is included in the Russian State Register of Measuring Instruments.
Produced in: Belarus, Minsk
Container-bath 400 ml
Container-bath 400 ml
from 163 ₽
The container-bath is designed for painting micro-preparations on slides in research laboratories. It is recommended to use in conjunction with a tripod DPS-20. The required working volume is 245-250 ml. The compact size ensures ergonomic placement in the workplace.
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA and separation gel, 1ml, 13×75mm, purple, glass, pack.100 pcs.
Vacuum tube MiniMed with K2-EDTA and separation gel, 1ml, 13×75mm, purple, glass, pack.100 pcs.
from 1 592 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Set of devices for BNTI-05-04 State Standard 20287 method B
Set of devices for BNTI-05-04 State Standard 20287 method B
It is used in determining the pour point of petroleum products in accordance with the State Standard 20287 (method B).
Produced in: Tomsk
Salt low-temperature bath SHS-6.5.6,2/5,5
Salt low-temperature bath SHS-6.5.6,2/5,5
from 2 561 724 ₽
Salt baths (furnaces) are used for low tempering of steels, annealing and heating for hardening of aluminum alloys, for tempering aluminum alloys, for tempering high-speed steel and for the first stage of heating high-speed steel. The low-temperature saltpeter bath SHS-6.5.6.2/5.5 is designed for heat treatment of parts in a saltpeter melt at temperatures up to 550 ° C in stationary conditions.
Produced in: Tula
Furnace control cabinet SHUP-25-1
Furnace control cabinet SHUP-25-1
Designation SHUP-25-1 Switching power, kW 25 Automatic switch, A 50 Supply network voltage, V/Hz 380
Produced in: Tula
Hinged cabinet LAB-M NSHS-1 120.35.70
Hinged cabinet LAB-M NSHS-1 120.35.70
Furniture for laboratory work. Mounted storage cabinet Length, mm: 1200 Depth, mm: 350 Height, mm: 700 PACKAGE CONTENTS the case is white melamine with a thickness of 16 mm, the ABS edge is dark gray two compartments. The left compartment with a hinged door, the right one is open the facade of the left compartment is tinted light gray glass in the right compartment there is 1 built–in shelf, in the left compartment there is 1 easily removable shelf with the possibility of rearrangement at 5 levels in height the permissible load on the shelf is 20 kg.
LOIP
Saint Petersburg
Produced in: Saint Petersburg