Search

3937 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 550
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3937 products
A set of devices for studying the properties of electromagnetic waves
A set of devices for studying the properties of electromagnetic waves
The set of devices includes a microwave transmitter module, a microwave receiver module, a set of devices (metal reflecting screens, a refractive prism, an absorbing screen, etc.) to demonstrate the properties of electromagnetic waves (radiation, absorption, reflection, refraction, interference, diffraction). Technical specifications: The wavelength of the microwave transmitter is 3 – 4 cm; The average value of the energy flux density emitted by the microwave transmitter meets the requirements of the SanPiN 2.4/2.1.8.9-36-2002 (no more than 10 MW/ sq. m.). Receiver (transmitter) weight, not more than 0.3 kg Overall dimensions of the receiver (transmitter) 172x25x77 mm The microwave receiver module has a built-in interface for connecting to a personal computer and provides the ability to display the measured information on the PC screen. The kit includes an electronic media with software (CD-ROM) to demonstrate the operation of the equipment on the monitor screen of a personal computer.
MNIPI
Minsk
Produced in: Belarus, Minsk
Low-frequency signal generator G3-132
Low-frequency signal generator G3-132
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 0.1 Hz to 10 MHz Frequency setting error ±0.02% Frequency instability ±0.01% in 15 min Signal amplitude ± 2.5 V at 50 ohm load ±5 V without load Limits of adjustment of the output signal level from 2 mV to 1.85 V (skz) at a load of 50 ohms from 4 mV to 3.75 V (scz) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz relative to 1 kHz ± 2% at frequencies from 10 Hz to 1 MHz ±10% at frequencies from 1 to 10 MHz Harmonic coefficient ± 0.2% at frequencies from 10 to 100 Hz ±0.07% at frequencies from 100 Hz to 20 kHz ± 0.2% at frequencies from 20 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 10 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V In the frequency range from 0.1 Hz to 2 MHz, the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Installation of pollution control of personnel RZBA-07D
Installation of pollution control of personnel RZBA-07D
Purpose: measuring the level of contamination of hands, feet (shoes) and clothing of personnel with beta-active substances and signaling when exceeding permissible levels monitoring the level of contamination with alpha-emitting radionuclides monitoring the contamination of personnel at nuclear power plants, nuclear fuel cycle enterprises (NFC), radiological laboratories, other enterprises and institutions using radioactive substances.
Doza
Zelenograd
Produced in: Moscow
Heat exchanger TO-290/ TO-145
Heat exchanger TO-290/ TO-145
It is used in technological processes of nuclear, thermal and electric power plants, boiler houses and other facilities for cooling samples supplied to automatic and manual chemical control devices.Easy-to-clean collapsible structure. Materials with high mechanical properties are used: the coil is made of 316 SS steel, the body is made of 304 steel (or 12X18H10T). It is equipped with crimp fittings for connecting sample lines without welding. It is equipped with a special three-way ball valve for supplying / draining cooling water and a control valve that provides a change in the flow of cooling water through the heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow
Vacuum tube MiniMed with lithium heparin, 6 ml, 13×100 mm, green, PET, pack.100 pcs,
Vacuum tube MiniMed with lithium heparin, 6 ml, 13×100 mm, green, PET, pack.100 pcs,
from 804 ₽
Test tubes are used to count blood cells and study plasma parameters. When mixed with the collected material, heparin blocks the activity of thrombin and inhibits the transition of soluble fibrinogen to insoluble fibrin, inactivating the coagulation factors irreversibly. Material for research............... heparinized blood, plasma Scope of application............................ immunology, hematology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Island LAB table-2400 OK
Island LAB table-2400 OK
equipment 2 countertops 2 racks, each support racks – aluminum profile painted with powder paint (RAL 1001) top panel 190mm deep – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
NV-800 SHB Cabinet for two gas cylinders (800*460*1820)
NV-800 SHB Cabinet for two gas cylinders (800*460*1820)
from 16 242 ₽
The cabinet is made of laminated chipboard with a 2 mm shockproof PVC edge on the facade. The standard equipment of the NV-800 SB includes: 2 doors; chain mount for 2 cylinders.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Piezoelectric vibration measuring transducers DN-3-M1, DN-3-M1 B6
Piezoelectric vibration measuring transducers DN-3-M1, DN-3-M1 B6
Vibration transducers DN-3-M1 are designed to measure vibration by converting mechanical vibrations into electrical signals proportional to the vibration acceleration of an oscillating object. Vibration converters DN-3-M1 are used in conjunction with vibration measuring devices in factory and laboratory conditions.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
CRYO-VT-80 Low-temperature liquid thermostat
CRYO-VT-80 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling power of 100 W at -80 °C. An internal bath with a volume of 9 liters and a depth of 200 mm. The operating temperature range is -80...+20 °C. Overall dimensions 330x660x820 mm Weight 73 kg Power consumption 4.2 kW.
Produced in: Tomsk
Central Heating Unit Medium (CHU-M) Kit
Central Heating Unit Medium (CHU-M) Kit
The kit is designed to control the temperature and pressure at the points of water sampling of hot water and HVAC systems, archiving the measured results for the purpose of their further documentation and analysis. The TSTP-M kit allows you to record changes in temperature and pressure directly at the points of water intake of hot water and HVAC, for a long period. With the subsequent transfer of data recorded in the device's memory to a computer, for printing a report, graph, etc. Features of the CHU-M kit The CHU-M kit allows you to control the pressure and temperature at the hot water and HVAC disassembly points. The kit consists of a four-channel meter recorder, which allows you to store 15,000 values in memory, for each channel with an interval of 5 seconds. up to several hours, which allows you to take measurements and store data for up to 1 year.
Produced in: Kolomna, Moscow region
Adsorption dryers with hot regeneration
Adsorption dryers with hot regeneration
The Provita company offers adsorption dryers with cold and hot regeneration of its own production. Industrial installations are equipped with high-quality components that ensure reliability and long service life. They are capable of operating at a pressure of 4 to 16 bar and are drained to a TRD (dew point under pressure) of -70 ° C. Working pressure: 4 — 16 bar Dew point: -20 to -70°C Capacity: from 50 to 20000 m3/hour
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Digital two-channel contact thermometer TK-5.27 with logging function
Digital two-channel contact thermometer TK-5.27 with logging function
from 28 704 ₽
The digital contact thermometer TK-5.27 is designed to measure the temperature of liquid, bulk, gaseous materials by immersion of measuring probes of thermometers into the medium (immersion measurements), contact measurements of temperatures of surfaces of solids (surface measurements), measurement of relative humidity of gaseous non-aggressive materials, measurement of atmospheric pressure, measurement of air flow velocity, as well as for measuring the luminous flux incident on a small area of the surface to its area. The contact thermometer TK-5.27, depending on the order, is equipped with replaceable probes for various purposes. Two probes of any type can be connected to the TK-5.27 thermometer at the same time. Thermometers TK-5.27 have the function of automatically determining the type of connected probe.
Produced in: Moscow