Search

3937 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 550
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3937 products
Portable flow meter-sampler of gas-aerosol mixtures PVP-06
Portable flow meter-sampler of gas-aerosol mixtures PVP-06
Purpose measurement and control of the pumping speed and the total volume of the aerosol mixture pumped through the filters installed on the product during sampling in order to determine the content of aerosol pollutants in the air
Doza
Zelenograd
Produced in: Moscow
Muffle furnace LF-5/13-V1
Muffle furnace LF-5/13-V1
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x190 mm Overall dimensions, WxHxD, not more than mm 505x955x565 Rated supply voltage, 220 V Rated power, W 2800
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Non-rotating CF flanges
Non-rotating CF flanges
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
MARK-2010
MARK-2010
Portable device for periodic measurement of the volume fraction of oxygen in various gases (hydrogen, natural gas, nitrogen, argon, helium, etc.). Mainly used for monitoring oxygen in the cooling circuit of generators, electrolysis plants, gas pipelines of boilers, monitoring the air of the working area. The warranty is 24 months for deliveries across the Russian Federation. High-precision measurement of oxygen microconcentrations Unique, patent-protected sensor design Exceptional selectivity to oxygen molecules Insensitivity to humidity, carbon dioxide, oil vapor Stable operation in a gas environment of any composition Ease of operation Automatic temperature and barocompensation The duration of measurements is 2-3 minutes Atmospheric air calibration Routine maintenance - no more than 1 time per year Built-in flow stimulator for forced sample delivery High contrast LED indicator IP54 housing case Protection from dust and moisture Built-in long-lasting battery At least 1000 charge/discharge cycles Carrying strap
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Optical Transceiver Gigabit Ethernet/Fiber channel (1.25Gbps)
Optical Transceiver Gigabit Ethernet/Fiber channel (1.25Gbps)
from 686 ₽
Optical transceivers are in standard SFP metal cases with a combined optical input/output for SC, LC connectors for transmitting a signal over a communication line - one optical fiber.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Seal for Mettler Toledo T50, T70, C20, C30, V20, V30 Titrators
Seal for Mettler Toledo T50, T70, C20, C30, V20, V30 Titrators
from 2 700 ₽
A set of ring seals for burettes of Mettler Toledo titrators of the T, DL, V series, as well as pumps for changing reagents of Solvent manager. In a package of 5 pcs. Material: fluorosiloxane rubber. The flat ring seal is used to seal the burette and bottle of the Mettler Toledo T50, T70, T90, G20, G10, V20, V30, C20, C30, DL titrators, as well as the pump and bottle of the Fischer reagent replacement module.
LABEX
Saint Petersburg
Produced in: Saint Petersburg
Vibration velocity sensors with current output DVST-1
Vibration velocity sensors with current output DVST-1
Vibration velocity sensors with a current output DVST-1 are designed to convert the RMS value of the vibration velocity of an object into a standard current signal of 4-20 mA.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Island LAB table-1200 FROM
Island LAB table-1200 FROM
EQUIPMENT rack support racks – aluminum profile painted with powder paint (RAL 1001) top panel with a depth of 190mm – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Metolab 501 Vickers Hardness Tester
Metolab 501 Vickers Hardness Tester
METOLAB 501 is a stationary hardness tester using the Micro-Vickers method, on the HV scale, as well as on the Knoop – HK scale. The device allows you to determine the hardness of various products (steel, cast iron, non-ferrous metals and soft alloys) in full compliance with GOST R ISO 6507-1-2007. The METOLAB 501 hardness tester has high accuracy, a wide measurement range (5-2500 HV), is equipped with a vernier micrometer, and also allows you to apply a wide range of loads in the range from 10 to 1000 gr. The principle of operation of the METOLAB 501 hardness tester is based on the indentation of a pyramidal diamond indenter with a certain force into the controlled surface of the sample. After the designated time, the indenter rises. The hardness value is calculated according to the diagonal of the print (depth), or calculated by the formula. Stationary automatic METOLAB 501 hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 66668-17 and comes with a certificate of primary verification (on request). Distinctive features of the stationary METOLAB 501 Micro-Vickers hardness tester: Simple and intuitive interface in Russian; Wide range of measured values – from 5 to 2500 HV; Wide range of test loads with manual switching – 0.09807 N (10 g), 0.2452 N (25 g), 0.4903 N (50 g), 0.9807 N (100 g), 1.961 N (200 g), 2.942 N (300 g), 4.904 N (500 g), 9.80 N (1 kg); Bright and clear LCD display that displays all the necessary information (set load, exposure time, test mode); Manual input of the diagonal length using a membrane keyboard; Vernier micrometer. Basic delivery package: Stationary METOLAB 501 Micro-Vickers Hardness Tester; Standard hardness sample – 2 pcs.; Flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow
Universal frequency meter Ch3-95
Universal frequency meter Ch3-95
The frequency meter is capable of operating both autonomously and as part of automated measuring systems with interfaces such as BUSB, RS-232, ETNET and IEEE-488 (CPC). Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (37.5 – 78.33) GHz Pulse duration 5 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Frequency measurement resolution 2x10-10 s/Rng Setting range of trigger levels (inputs A, B) from -2 to 2 V The error of setting the trigger levels (inputs A, B) ± 0.01 V Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 10.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) 0.5 MW - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 24 months Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 299x130,5x433 Weight, not more than 8.5 kg
Produced in: Moscow
 Portable kit for magnetic particle flaw detection Pole-M1
Portable kit for magnetic particle flaw detection Pole-M1
The Pole-M1 kit is used for monitoring pipelines, cranes, stanchions, beams and other ferromagnetic products, machine-building parts and workpieces for the presence of surface and subsurface defects (cracks, shells, etc.). It is designed to work in workshop, laboratory and field conditions. A permanent magnet allows you to monitor various shaped parts, welds and various products for cracks, discontinuities, shells and similar defects by magnetizing individual controlled areas or the product as a whole. The permanent magnet as part of the Polyus-M1 set of highly stable magnets with high maximum specific magnetic energy is designed to detect surface and subsurface defects in products made of ferromagnetic materials by magnetic powder or magneto-luminescent method and refers to portable specialized means of magnetic control.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Wide neck clear glass vials
Wide neck clear glass vials
from 20 ₽
Vials are used to protect the basic properties of chemical, pharmaceutical and other liquid, paste-like, mixed fluid products. Designed for scientific research. Not intended for medical use. Material: Polypropylene (polypropylene copolymers). The addition of a nucleator (illuminator) is allowed for greater hardness (if necessary). Color: Transparent. Autoclaving process is performed for 30 minutes at a temperature of + 121OC and a pressure of 2.1 atm. Drying is carried out at +85OC for 3 hours. The products are resistant to substances containing active chlorine, guanidine, alcohols, acetone
SkyGen
Moscow
Produced in: Vladimir