INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
Transmission of units of absorbed dose, directed, individual dose equivalents and their beta radiation power as part of the working standard of absorbed dose (PD) and absorbed dose power (MPD) of beta radiation in a tissue equivalent substance. ▪ Use of closed radionuclide beta radiation sources 90Sr+90Y (BIS-50, 22 GBk), 85Kr (KAC.D3, 15 GBk) and 147Pm (BIP-50, 10 GBk) ▪ Formation of a reference field from sources by a mobile emitter unit using smoothing filters ▪ Source holders with shutter and protective screens ▪ Calibrated length rods and laser device for centering and digitizing ▪ A video surveillance system of readings ▪ The possibility of using an automated extrapolation chamber as part of the installation to reproduce the absorbed dose (absorbed dose rate) of beta radiation in the tissue ▪ Measurement of ionization currents from 1 fA when using an extrapolation chamber and a precision electrometer ▪ Software for installation operation, calibration and calculations ▪ An alarm and blocking system, control of photon radiation levels in the measurement room and operator room
Produced in: Belarus, Minsk
Surface smart probe L=150 mm SZPV.150
Surface smart probe L=150 mm SZPV.150
from 10 920 ₽
The surfaCE SMART probe L=150 mm SZPV.150 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor based on the Android program. Operating conditions of the SZPV.150 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPV.150 smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Muffle furnace LF-7/13-G1
Muffle furnace LF-7/13-G1
Design features: Durable ceramic muffle; Semi-open heaters on four sides of the chamber Microprocessor temperature controller; Conveniently located control panel and bright LED display; Automatic shutdown of heating when opening the door; Ease of management and control; LED indicators of heater operation and protection operation; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x285 mm Overall dimensions, WxHxD, not more than 505x565x655 mm Rated supply voltage, 220 V Rated power, W 3300
LOIP
Saint Petersburg
Produced in: Saint Petersburg
TS-V-1 Dry Cooler
TS-V-1 Dry Cooler
from 67 173 ₽
Dry coolers (autonomous cooling system) are designed to circulate and cool the liquid, which ensures the permissible temperature of the heat-generating object. The product is adapted to work with vacuum drying cabinets of the "SNVS" and "SHSV" type manufactured by TULA-TERM LLC, having a liquid-cooled flange, as well as any equipment using liquid cooling and suitable in characteristics.
Produced in: Tula
Circulation thermostat LT-216a
Circulation thermostat LT-216a
The LOIP LT-216a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 16 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x42 0 Weight, kg 11.5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LB12-18/8K Basket
LB12-18/8K Basket
Eight holes with a diameter of 17 mm will serve to accommodate glass tubes, the remaining nine ventilation holes — for better convection of the coolant. Internal dimensions 240x120x210 mm Weight 1 kg
Produced in: Tomsk
Vacuum tube MiniMed with K2-EDTA, 5 ml, 13×100mm, purple, glass, pack.100 pcs
Vacuum tube MiniMed with K2-EDTA, 5 ml, 13×100mm, purple, glass, pack.100 pcs
from 1 235 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
AO-3 cooler
AO-3 cooler
1 supp.
According to the requirements of the standards, the cooler is included in the list of equipment for determining humidity with pre-drying. Usually, grain samples after preliminary drying are cooled in the laboratory room to ambient temperature. However, with such cooling, the ambient temperature reaches only the surface layers of the samples, which affects the results of the analyses. The principle of operation of the cooler is based on blowing sample canopies in mesh buckets placed on a stand by a fan rotating at high speed. Advantages: Rapid cooling of samples. Stable moisture distribution. Allows you to significantly improve the accuracy of the results of determining humidity.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
cabinet LAB-M SHO 80.50.194
cabinet LAB-M SHO 80.50.194
Furniture for laboratory work. Wardrobe Length, mm: 800 Depth, mm: 500 Height, mm: 1940 PACKAGE CONTENTS housing – melamine white with a thickness of 16 mm, ABS edge dark gray facades – melamine white with ABS edge dark gray 2 compartments (in the left - a shelf for hats, a rod for hangers, in the right - a shelf for shoes, a rod for hangers).
LOIP
Saint Petersburg
Produced in: Saint Petersburg
hydrogen meter MARK® 509 A
hydrogen meter MARK® 509 A
Continuous measurements of dissolved hydrogen concentration and temperature of aqueous media with excess hydrostatic pressure up to 20 MPa Unique, patent-protected sensor design | Stability of operation with changes in hydrostatic pressure | Permissible short-term (up to 5 minutes) pressure overload (water hammer) – up to 40 MPa | Easy and fast membrane replacement | The sensor is not afraid of "drying" | The calibration interval is 6 months | Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
LB13-18/24K Basket
LB13-18/24K Basket
The height-adjustable bottom allows the tubes to be immersed in the coolant to the required depth. Internal dimensions 255x150x215 mm Weight 1 kg
Produced in: Tomsk
Rubidium frequency standard H1-1022
Rubidium frequency standard H1-1022
Rubidium frequency standards H1-1022 are available both in the standard version and with various options that have differences in functionality and technical characteristics: option 01 is a device with high short–term stability of the output signal frequency; option 02 – a device with a low-level phase noise in the output signal spectrum; option 03 – the device has a binding module in its composition, which allows automatic correction of the frequency of the output signal according to the signal of the external time scale; option 04 – the device has a synthesizer module in its composition, which allows you to receive a sinusoidal signal of a given frequency at the output of the device in the range from 100 Hz to 100 MHz in steps of the order of 4 × 10-6 Hz; option 05 is a device with an extended range of ambient operating temperatures. Through the built-in RS-232 interface, telemetry information is collected from the device nodes, and commands to change the frequency of the output signal are transmitted. The H1-1022 frequency standards have no domestic analogues in terms of their small dimensions, weight, power consumption and operating time, as well as in terms of their numerous functional capabilities.