TERKON-K signal switchboard
TERKON-K signal switchboard
It serves to increase the number of input channels. Up to 16 temperature sensors can be connected to the switch inputs simultaneously. Measurement time of 2 channels 1 s The time of setting the operating mode is 30 minutes Overall dimensions 185x150x25 mm Weight 1 kg
Produced in: Tomsk
Gamma radiation detector threshold stationary SRPS-05D
Gamma radiation detector threshold stationary SRPS-05D
A simple and reliable device for monitoring the radiation situation in rooms where work is carried out with radioactive sources (substances, medications, installations). If the set threshold value of the dose rate is exceeded, the device gives a sound and light signal, controls external devices (for example, door locking devices). Purpose: measurement of the ambient dose equivalent of gamma radiation (MAED); sound and light alarm about exceeding the set threshold; activation of external signaling or actuating devices.
Doza
Zelenograd
Produced in: Moscow
Vacuum tube MiniMed with coagulation activator and separation gel, 8.5ml,16*100 mm, yellow-orange, PET,pack.100 pcs.
Vacuum tube MiniMed with coagulation activator and separation gel, 8.5ml,16*100 mm, yellow-orange, PET,pack.100 pcs.
from 1 710 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Research material............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K3-EDTA, 9 ml, 16×100mm, purple, PET, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA, 9 ml, 16×100mm, purple, PET, pack.100 pcs
from 1 021 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region
Island table low LAB-PRO SOCn 90.150.75 TR-E16/23
Island table low LAB-PRO SOCn 90.150.75 TR-E16/23
Combined work surface: main table top TRESPA TopLabPlus 16/23mm (with a side made of composite material based on epoxy resins, the height of the side above the table top is 7 mm, depth 30 mm) 650 mm deep / auxiliary table top made of TRESPA material 200 mm deep / main table top TRESPA TopLabPlus 16/23mm 650 mm deep Length, mm: 900 Depth, mm: 1500 Height, mm: 750 BASIC EQUIPMENT The base is a collapsible metal frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Four easily removable screens (RAL 7035) and two non-removable (RAL 5023) Hidden fasteners Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Cabinet with fast pumping SNVS-6.5/3.5 BO
Cabinet with fast pumping SNVS-6.5/3.5 BO
The SNVS-6.5/3.5 BO vacuum drying cabinet is designed for rapid degassing of compounds and silicones at temperatures up to 350 ° C and an average vacuum of up to 5x10-2 mmHg (Determined by the range of installed sensors). The electric cabinet is made on a stand with wheels. In the upper part there is a vacuum drying chamber and a control system. In the lower part there is a vacuum system. The tight closing of the door is provided by a rotary-eccentric type mechanism and a silicone door seal. In the central part of the door there is an observation window Ø200 mm made of high-temperature quartz glass with a thickness of 20 mm with the illumination of the working chamber installed on it. Coating the cabinet body with powder paint. The control is carried out by a panel software controller located on the door.
Produced in: Tula
Universal calibrator H4-301/1
Universal calibrator H4-301/1
Technical specifications: Voltage reproduction range Uk 200 mV 0.07 + 0.01 DC: from 50 MV to 600 V, Uk 2 V 0.05 + 0.005 sub-bands (UK) 200 MV; 2; 20; 200; 600 V Uk 20 V 0.05 + 0.005 Basic error, ± (% of U + % of Uk): Uk 200 V 0.07 + 0.01 Uk 600 V 0.1 + 0.02 Voltage reproduction range Uk 200 mV 0.2 + 0.05 AC: from 1 mV to 600 V, sv. 20 to 40 kHz 0.2 + 0.1 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V Uk 2; 20 V 0.15 + 0.02 Basic error, ± (% of U + % of Uk): from 20 Hz to 20 kHz 0.15 + 0.02 Uk 200 V; 600 V: 0.2 + 0.05 from 40 Hz to 1 kHz 0.2 + 0.05 DC power reproduction range: from 1 Ma to 200 mA, sub-bands (Ic) 200 Ma; 2; 20; 200 mA Ic 200 Ma 0.1 + 0.02 Basic error, ± (% of I + % of Ic): Ic 2; 20; 200mA 0.1 + 0.01 Power reproduction range AC: from 10 Ma to 200 mA, sub-ranges (Ic) 200 Ma; 2; 20; 200 mA 0.15 + 0.05 Frequency range from 20 Hz to 1 k Hz Basic error, ± (% of I + % of Ic): USB interface Operating temperature range from minus 10 to +50 C Dimensions; weight 428×327×235× mm; 10 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Membrane nitrogen plants
Membrane nitrogen plants
A membrane nitrogen plant is a set of special equipment designed to produce nitrogen from atmospheric air by the method of membrane separation at a pressure of up to 25 bar. The production of nitrogen in this technological process is based on the principle of separation of gas mixtures in a membrane module, due to the different penetration rates of the components of the gas mixture through polymer membranes and the differential partial pressures on both sides. In the case of separation of the air mixture, oxygen has a greater permeability than nitrogen. The difficult-to-penetrate gas components (N2, CH4, CO) pass along the entire length of the generator and then come to the consumer. The output is a gas mixture with an N2 content of up to 99.9%. The membrane installation allows to obtain high-pressure production gas (nitrogen). The composition of a standard membrane nitrogen production plant: Air compressor; Dehumidifier; Main filter block, including coal column; Air receiver; Membrane generator; Production gas receiver.
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Portable Electrical Laboratory for cable damage detection by Acoustic and Induction method Athlete KAI-1.502 (IDM)
Portable Electrical Laboratory for cable damage detection by Acoustic and Induction method Athlete KAI-1.502 (IDM)
Appointment Athlete KAI-1.502 (IDM) • Search for a live cable. • Detection of the passage of hidden communications (metal pipelines, cable lines). • Preliminary detection of the distance to the place of damage. • Search for places of cable damage in an acoustic way. • Search for places of cable damage by electromagnetic means. The presence of the "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
Vacuum tube MiniMed with sodium citrate 3.2%, 4.5 ml,13*75 mm, blue, PET,pack.100 pcs,
Vacuum tube MiniMed with sodium citrate 3.2%, 4.5 ml,13*75 mm, blue, PET,pack.100 pcs,
from 693 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 87 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with automatic regulation SNVS-90/5
Vacuum drying cabinet with automatic regulation SNVS-90/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula