Search

3939 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 549
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3939 products
Optical transceiver Bi-directional 1x9 receptacle/OS3/STM1/FastEthernet (155Mbps)
Optical transceiver Bi-directional 1x9 receptacle/OS3/STM1/FastEthernet (155Mbps)
from 5 741 ₽
Optical transceivers are available in 9-pin plastic cases with a single optical input/output for SC type connectors.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Set of devices EN 23015 (ASTM D97)
Set of devices EN 23015 (ASTM D97)
It is used for determining the turbidity or fluidity temperature of petroleum products in accordance with EN 23015 and ASTM D97. For testing, additional sets of devices BNTI 05 04 K and BNTI 05 04 3K are required.
Produced in: Tomsk
BE-8 laboratory bidistillator
BE-8 laboratory bidistillator
from 158 400 ₽
Purpose: obtaining distilled water of type 2 according to GOST R 58144-2018 "Distilled water", FS.2.2.0019.18 "Water for injection" Capacity: distillate: 9.0 (-10%) l/h, bidistillate: 8.0 (-10%) l/h Heating elements: 1st stage of distillation: Heating element 2.0 kW 220V (stainless steel) – 3 pcs., 2nd stage of distillation: Heating element 1.8 kW 220V (stainless steel) – 3 pcs. The quality of the produced water: GOST R 58144-2018 "Distilled water", FS.2.2.0019.18 "Water for injection" Type of current, frequency, voltage: alternating, single-phase, 50 Hz, 380 V Power consumption in distillate production mode: 6.0 kW, in bidistillate production mode: 11.4 kW Overall dimensions (L×W×C), mm: 675×365×470 Weight: 30.0 kg Warranty period: 12 months from the date of sale Electrical conductivity of the produced water: bidistillate: 1.0-1.2 microns/cm, distillate: no more than 5.0 microns/cm The temperature of the produced water: distillate: from 70 to 85 ° C, bidistillate: no more than 40 ° C Source water consumption (at t of water 10 ° C) in the distillate production mode: 72.0 (±10%) l/h, in the bidistillate production mode: 168.0 (±10%) l/h Source water pressure 0.1-0.4 MPa Version: Desktop with adjustable supports. Wall mounting is possible Coefficient of water purification from radionuclides: at least 4000 Service life: at least 8 years
Livam
Belgorod
Produced in: Belgorod
Monoblock liquid cooling unit MCHV-300
Monoblock liquid cooling unit MCHV-300
Cooling capacity at water temperature = +20C, output.water=+15C, Current.cp.=+30C, 300 kW
Produced in: Tula
Vacuum tube MiniMed with K3-EDTA, 8 ml, 16×100mm, purple, PET, pack.100 pcs.
Vacuum tube MiniMed with K3-EDTA, 8 ml, 16×100mm, purple, PET, pack.100 pcs.
from 928 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region
Wall-mounted high table LAB-PRO SPCv 90.80.90 KG-ES
Wall-mounted high table LAB-PRO SPCv 90.80.90 KG-ES
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
NV-600 TD Cabinet on wheels with two doors (600*460*650)
NV-600 TD Cabinet on wheels with two doors (600*460*650)
from 5 737 ₽
The NV-600 TD cabinet on wheels has two doors, a shelf-insert and wheels. The standard version of the cabinet on wheels for the laboratory table includes: 2 hinged doors; insert shelf; 2 mm shockproof PVC edge on the countertop and facade; plastic wheels. In the standard version, we offer cabinets for laboratory tables in gray color. However, in agreement with the customer, it is possible to change the color to white, without increasing the cost. We are also ready to adapt the size and materials so that they meet your needs.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Trace Searcher Success AG-309.20M (frost-resistant)
Trace Searcher Success AG-309.20M (frost-resistant)
from 188 370 ₽
The trace searching kit is designed to accurately determine the location and depth of underground utilities (power and signal cable lines, reinforced fiber-optic lines, pipelines made of electrically conductive materials), troubleshooting cable lines, and also allows you to conduct a survey of the area in the shortest possible time and with great reliability before excavation and to prevent damage to engineering communications. As part of the kit, the receiver is in the form of a monoblock with a frost-resistant LCD display, which displays an image of the route and automatically calculates the depth of communication up to 10 m, as well as the current in the line. Compact stand-alone generator with display and built-in induction antenna. The output power of the generator is up to 20 watts and the operating range is up to 3 km.
Produced in: Kolomna, Moscow region
Muffle furnace LF-15/13-G2
Muffle furnace LF-15/13-G2
Design features: Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; The door opens up and faces the user with the cold side; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than mm 215x190x330 Overall dimensions, WxHxD, not more than mm 525x655x680 Rated supply voltage, 220 V Rated power, W 6100
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Sulfur Analyzer SPECTROSCAN SW-D3
Sulfur Analyzer SPECTROSCAN SW-D3
The analyzer is designed to determine the mass fraction of sulfur in automotive fuel in accordance with GOST R 52660-2006 / GOST ISO 20884-2016, ASTM D6334, as well as in oil and petroleum products according to GOST R 53203-2008 / GOST 33194-2014, ASTM D2622, GB/T 11140-2008. Depending on the customer's needs, the analyzer is configured to work in accordance with a particular standard. Implements an arbitration method for measuring the mass fraction of sulfur in automobile fuel of the third, fourth and fifth classes. The device is designed specifically for high-quality and fast X-ray fluorescence analysis of fuel in accordance with the technical regulations "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and heating oil", which establishes an arbitration X-ray fluorescence wave dispersion method for determining the mass fraction of sulfur in automotive fuels of the third, fourth and fifth classes. The wave dispersion sulfur analyzer SPECTROSCAN SW-D3 is designed taking into account all the requirements for the process of X-ray fluorescence elemental analysis of low sulfur contents in petroleum products. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of sulfur in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg