Search

3959 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 552
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3959 products
VEGA
VEGA
The ultimate display quality is ensured by the use of built-in acoustic and vibration isolation, thermal stabilization, the industry's best sensitivity of the optical recording system and the unique design of the scanning probe system, which allows achieving atomic resolution in routine measurements. In the basic configuration, 50+ AFM techniques are available, including the HybriD method, which allows conducting all cutting-edge nanomechanical, electrical and magnetic studies. Intelligent ScanTronic™ algorithm for one-click optimization of scanning parameters, which allows for perfect relief measurements using the amplitude-modulation method, regardless of the operator's experience. Automated examination of multiple samples using a simple user interface to create a point-by-point scanning scenario and a database for stored received images. Control of samples with dimensions up to 200×200 mm and thickness up to 40 mm at any point of the surface with a positioning accuracy of 1 micron. Wide customization possibilities: installation of additional optical equipment, development of specialized sample holders, combination with a transport system, automation of measurements and data analysis in accordance with customer requirements.
Produced in: Moscow, Zelenograd
Laboratory hydrocracking/gasification unit
Laboratory hydrocracking/gasification unit
The laboratory unit is designed to study the catalytic and thermal processes of processing heavy petroleum raw materials. The installation allows you to explore the following processes: 1. Hydrocracking 2. Thermal cracking 3. Gasification of water dispersions of coal, biomass, heavy oil residues. The high-pressure liquid pump operates at temperatures up to 200°C, which makes it possible to supply high-viscosity components (fuel oil, tar, paraffin, ceresin, etc.) to the reactor. The laboratory unit is manufactured in accordance with the technical requirements of customers so as to correspond to a wide range of technological parameters. The modular configuration of the unit allows you to change or upgrade it at any time for new tasks. Main advantages: 1. The possibility of developing and supplying a reactor to meet customer requirements; 2. A wide range of accessories for the supply of liquids/solids; 3. Visual process control; 4. A system of control and regulation of technological parameters; 5. Convenience of loading and unloading of raw materials and reaction products; 6. The possibility of conducting long-term tests in continuous mode; 7. The possibility of upgrading the structure for new purposes; 8. Control and accurate reproduction.
Produced in: Rostov region, Novocherkassk
Tablet for slides for 20 places, p/s, ind.up.
Tablet for slides for 20 places, p/s, ind.up.
from 195 ₽
Designed for drying and storage of slides measuring 76x26 mm in research laboratories. Made of polystyrene.
MiniMed
Suponevo
Produced in: Bryansk region
Vibration converter VT-003
Vibration converter VT-003
The VT-003 vibration transducers are designed to convert the instantaneous value of the vibration acceleration of an object into an ICP signal of the IEEP standard.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Laboratory radio installation table SR-180.64.76.PLC
Laboratory radio installation table SR-180.64.76.PLC
A table with an overall height of 1860 mm with a table top made of MDF with a plastic coating. It is designed for long-term operation, the power frame does not contain aluminum and plastic parts in the fasteners. Overall dimensions without superstructure 1800x640x760 mm Overall dimensions with superstructure 1800x640x1860 mm
Produced in: Tomsk
Power supply B5-89, B5-89/1
Power supply B5-89, B5-89/1
Technical specifications: Indicator name, unit of measurement, Indicator value, B5-89, B5-89/1 The range of the output voltage setting, the limits of the absolute error of the output voltage setting:- basic error, In; - in operating conditions, In, from 0 to 30.0 ± 0.2± 0.3, from 0 to 100.0 ± 0.3± 0.45 The range of the output current setting, the limits of the absolute error of the output current setting:- basic error, A; - in operating conditions, A, from 0 to 10.0 ± 0.2± 0.3, from 0 to 3.0 ± 0.1± 0.15 Instability of the output voltage when the supply voltage changes by ± 10% of the nominal value in the voltage stabilization mode, %, ± 0.05, no more, Instability of the output current when the supply voltage changes by ± 10% of the nominal value in the current stabilization mode, %, ± 0.2, no more, Instability of the output voltage when the load current changes at the output terminals of power supplies in voltage stabilization mode, %, ± 1, no more, Instability of the output current when the load voltage changes in the current stabilization mode at minimum load currents, %, ± 5, no more, Instability of the output current when the load voltage changes in the current stabilization mode at maximum load currents, %, ± 0.5, no more, Output voltage ripple in voltage stabilization mode, mV, 1.0, no more, Output current ripple in current stabilization mode, %, 1, no more, Instability of the output voltage from time, V, ± 0.5, ± 1.0 Instability of the output current from time, A, ± 0.3, ± 0.2 AC power supply: - voltage, V; - frequency, Hz, 230 ± 2350 ± 0.5, Weight, kg, 13.0, no more, Overall dimensions, mm, 384x301x169
MNIPI
Minsk
Produced in: Belarus, Minsk
Metrological high-voltage laboratory of TECHNOAS
Metrological high-voltage laboratory of TECHNOAS
For primary and periodic verification and calibration at the field of operation of the following measuring instruments that are part of automated information and measurement systems for commercial accounting of electrical energy (AIIS KUE) or non-automated metering units: • – Measuring voltage transformers (TN) of accuracy classes 0.2 and less accurate at loads normalized by GOST, and at real loads at the metering unit. • – Measuring current transformers (TT) of accuracy classes 0.2S and less accurate with nominal primary currents of 100...5000 A (including high-voltage transformers for 330 kV lines) at loads standardized by GOST 7746-2001 and at real loads; single-phase and three-phase electric active and reactive energy meters of accuracy classes 0.2S and less accurate. • – Auxiliary SI: ammeters, voltmeters, wattmeters, voltage, current and power converters, accuracy classes 0.2 and less accurate, phase meters, power factor meters of accuracy classes from 0.10 and less accurate. • – Energy frequency meters of accuracy classes from 0.02 and less accurate, used at the electricity metering unit. • – For measuring the load capacity of TN iTT. • – For measuring voltage losses in secondary TN circuits. – For measuring the quality of electrical energy (PCE) in accordance with the requirements of GOST 13109-97.
Produced in: Kolomna, Moscow region
EVRAZTEMP Submersible thermocouples for one-time use.
EVRAZTEMP Submersible thermocouples for one-time use.
Purpose: Measurement of molten metal temperature Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, blast furnaces, casting buckets Measuring range: from 700°C to 1800°C Accuracy: 0 + 3°C at 1554°C Measurement time: 4 sec Tube Length: from 100 to 1800 mm (other length is possible on request) Slag Cap: Steel, uncapped, aluminum Splash protection: Refractory fiber Type of NSH: B, S, R
Produced in: Lipetsk
Aquarius Deionizer
Aquarius Deionizer
from 96 000 ₽
It is intended for obtaining in laboratory conditions from distilled especially pure (deionized) water used for the preparation of solutions, chromatographic samples, refueling of electrolytic hydrogen/oxygen generators and other purposes. Technical specifications The specific conductivity of the resulting water is not more than 0.20* mkSxcm Capacity is at least 6* l/h Metal ion content is not more than: Fe, Pb, Ni, Co 5* mcG/l Zn, Cd, Cu, Mn 1*m cG/l The optical density of ammonia relative to bidistilled water is no more, D - 0.01* Operating time of the replaceable cassette (total volume of purified water) is not less than 700 liters. Volume of refilled distilled water is 1 l Overall dimensions are 180x420x430mm  The weight of the filled device is no more than 9 kg Operating conditions: ambient temperature from +10 ° C to +35 ° C Power supply from single-phase AC 220 V., 50 Hz The power consumption is not more than 20 VA.
Produced in: Moscow
Rubidium Ch1-1014 Frequency Standard with GPS/GLONASS Signal Receiver Module
Rubidium Ch1-1014 Frequency Standard with GPS/GLONASS Signal Receiver Module
The signals of the navigation receiver's second mark and the RF available for the customer`s use are generated simultaneously on two high-frequency outputs of the receiver board. In the presence of stable reception of signals from satellites of the GLONASS and GPS radio navigation systems, the board ensures the operation of the RF in the frequency binding mode according to the signals of the second timestamp (the so-called “disciplined” rubidium frequency standard mode) with a relative error of the actual value of the RF frequency of no more than ± 5.0.10-12.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Muffle furnace LF-15/11-V2
Muffle furnace LF-15/11-V2
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Closed heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; The door opens up and faces the user with the cold side; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than mm 215x190x330 Overall dimensions, WxHxD, not more than 525x1045x680 mm Rated supply voltage, 220 V Rated power, W 6100
LOIP
Saint Petersburg
Produced in: Saint Petersburg
rhNog
rhNog
from 17 000 ₽
Nojin is a protein involved in the development of various tissues, including bone, muscle and nerve. It is an antagonist of bone morphogenetic proteins (MBPs). Noggin has been implicated in a number of pathological conditions.
Produced in: Moscow