3937 products
Measuring and diagnostic complex PKSOD-M
Measuring and diagnostic complex PKSOD-M
The proposed measuring and diagnostic complex is designed to: - provide monitoring of the technical condition of electric drive valves of nuclear power plants; – detection and identification of malfunctions of components and equipment of electric drive valves at an early stage of their occurrence; – issuance of measurement results and diagnostics of electric drive valves to the operational personnel of the station.
Produced in: Rostov-on-Don
Vacuum tube MiniMed with K3-EDTA, 7 ml, 13×100mm, purple, glass, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA, 7 ml, 13×100mm, purple, glass, pack.100 pcs
from 1 235 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Wall-mounted LAB table-1500 pcs
Wall-mounted LAB table-1500 pcs
EQUIPMENT rack support racks – aluminum profile painted with powder paint (RAL 1001) top panel with a depth of 190mm – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with coagulation activator and separation gel, 2ml, 13*75 mm, yellow-orange, glass,pack of 100 pcs.
Vacuum tube MiniMed with coagulation activator and separation gel, 2ml, 13*75 mm, yellow-orange, glass,pack of 100 pcs.
from 1 274 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Material for research............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA and separation gel, 5 ml, 13×100mm, purple,glass, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA and separation gel, 5 ml, 13×100mm, purple,glass, pack.100 pcs,
from 1 339 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Smart submersible reinforced probe  L=1000 mm SZPGU.1000
Smart submersible reinforced probe L=1000 mm SZPGU.1000
from 13 731 ₽
The smart submersible reinforced probe L=1000 mm SZPGU.1000 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPGU.1000 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPGU.1000 smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Metal tripod Sh-10/23, pack.12 pcs, MiniMedProm
Metal tripod Sh-10/23, pack.12 pcs, MiniMedProm
from 288 ₽
The tripod is made of aluminum, which allows them to be sterilized at any temperature; this material provides lightness and durability. It can be used in water baths. The tripod has an individual packaging. Designed for storing test tubes.
MiniMed
Suponevo
Produced in: Bryansk region
RUNWAY-101 platform scales
RUNWAY-101 platform scales
from 114 990 ₽
Technical specifications NIP, kg101 Discreteness, g5/(2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g500 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 500g to 50 kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 40kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Bellows hose with thermal insulation
Bellows hose with thermal insulation
Bellows hose with thermal insulation and an internal diameter of 10 mm is used to connect thermostats of the VTi CRYO-VT series to external consumers or as a jumper hose. We recommend it for use with PMS heat carriers at high temperatures.
Produced in: Tomsk
Mine vacuum furnace SNVS-6.5/12.5- I4
Mine vacuum furnace SNVS-6.5/12.5- I4
High-temperature furnaces are capable of heating materials up to 1700 degrees. The scope of their application covers the heat treatment of various materials in an inert medium or vacuum. TULA-TERM furnaces are used for heat treatment of plastics, ceramics, metals, alloys, lacquers and other materials. The equipment allows sintering, annealing, soldering, quenching, drying, burning and molding. In industry, our installations are most often used for quenching parts and sintering hard alloys.
Produced in: Tula
Electric cabinet vacuum drying SNVS-5,05.4,65.4,90/2-I2/2KV
Electric cabinet vacuum drying SNVS-5,05.4,65.4,90/2-I2/2KV
The electric vacuum drying cabinet SNVS-5,05.4,65.4,90/2-I2/2 KV is designed for drying and setting selected stages (up to 20 in each program) of the vacuum depth with automatic maintenance of the set value and automatic nitrogen (inert gas) supply to the chamber.
Produced in: Tula