Search

3959 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 552
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3959 products
Laboratory LAB table-900 LFn
Laboratory LAB table-900 LFn
equipment side decorative panels – melamine 16mm thick all-welded frame made of rectangular metal profile painted with white powder paint adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Bracket for mounting the AE-25 disstillator on the wall
Bracket for mounting the AE-25 disstillator on the wall
from 4 230 ₽
The bracket for mounting the distiller provides the possibility of not only desktop, but also wall-mounted installation of the aquadistillator at the required height
Livam
Belgorod
Produced in: Belgorod
MARK-409 Dissolved Oxygen Analyzer
MARK-409 Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance Automatic temperature and barocompensation. Automatic air oxygen calibration. Long-lasting sensor The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance from the sampling point Up to 100 meters. Communication with external devices Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port, MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable IP65 aluminum housing The device is reliably protected from dust and moisture. Graphic indicator with backlight Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
SHV NVK 900 Fume cupboards without plumbing
SHV NVK 900 Fume cupboards without plumbing
from 103 484 ₽
The SHV NVK 900 KG exhaust cabinet without plumbing (900×716×2200). Description: Exhaust laboratory cabinets are used when working with toxic and harmful volatile materials, with clean materials, with dissolution or decomposition under heat treatment, during sample analysis and many others. The base of the cabinet is an all-welded metal frame in powder coating. The side laminated panels (chipboard with a thickness of 16 mm) are edged along the facade with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. Characteristics: Additional illumination on the side with smooth adjustment; The extract from the lower cabinet allows you to store reagents in it; Exhaust pipe on the cabinet lid with a diameter of 150 mm; Shockproof lifting screen is easy to lift with one hand; The screen in the raised state does not increase the height of the cabinet; Inside the working chamber there is a shelf for storing reagents; Two moisture-proof sockets with a lid inside the working chamber; Special closers in the cabinet allow you to close the cabinet silently; On request, the countertops can be made of: chemical resistant plastic porcelain stoneware (tile) polypropylene stainless steel monolithic ceramics
NV LAB
Moscow
Produced in: Moscow, Moscow region
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Appointment Athlete KAI-2.1001 • Determination of the type of damage and the distance to the place of damage to the cable. • Tracing a cable line up to 10 km. • Determination of cable depth up to 6 m. • Troubleshooting of cable lines by induction method. • Troubleshooting of cable lines by acoustic method. • Cable insulation testing.
Produced in: Kolomna, Moscow region
NV-800 SPr Cabinet for devices (with 2 glass doors)
NV-800 SPr Cabinet for devices (with 2 glass doors)
from 17 202 ₽
The NV-800 SPr cabinet for devices with 2 glass doors. The cabinet is made of laminated chipboard with a 2 mm shockproof PVC edge on the facade. Included in the set: 2 glass doors for the upper compartment; 2 doors for the lower compartment; 4 shelf inserts; metal legs 100 mm high.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Crystallization bowl diam.125 mm, pack of 2 pcs
Crystallization bowl diam.125 mm, pack of 2 pcs
from 537 ₽
Designed for evaporation and recrystallization of chemicals. Made of TS glass according to GOST 21400-75.TU 4320-012-29508133-2009.
MiniMed
Suponevo
Produced in: Bryansk region
Dosimetric thermoluminescent complex "DOSE-TLD"
Dosimetric thermoluminescent complex "DOSE-TLD"
Purpose: measurement of the individual dose equivalent of Hp(10) photon radiation; measurement of the individual dose equivalent of Hp(10) neutron radiation; measurement of the individual dose equivalent in the skin Hp(0.07) and the lens of the eye Hp(3) of photon and beta radiation; measurement of ambient dose equivalent H*(10) of photon radiation.
Doza
Zelenograd
Produced in: Moscow
Mounted shelf LAB-1200 NSv
Mounted shelf LAB-1200 NSv
Furniture for laboratory work. Mounted shelving Length, mm: 1200 Depth, mm: 330 Height, mm: 690 PACKAGE CONTENTS case – melamine 16mm thick 1 built-in shelf suspension fasteners included
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Software and hardware complex with a set of sensors for physics classrooms
Software and hardware complex with a set of sensors for physics classrooms
The software and hardware complex with a set of sensors for physics classrooms is designed to measure physical quantities during demonstration work on various sections of physics, as well as to perform experimental work on physics. The set of units of the measuring system is compatible with a PC, has software with an instruction manual. The sensor kit includes 10 sensors for measuring the following physical quantities: - temperature sensor DTV-1 (measuring range -200C + 1100 S); - air humidity sensor DTV-1 (measuring range 10-100%); - pressure sensor DD-1 (measuring range 0-700 kPa); - acceleration sensor DUIMP-1 (measuring range - 4 – + 4 g); - permanent magnetic field induction sensor DUIMP-1 (- 8 – + 8 Gs); - illumination sensor DSCH-1 (measuring range 1 -60 000 lux); - distance sensor DR-1 (measuring range 0.04 – 4.0 m); - angular velocity sensor DUPUS-1 (remote) (measuring range 0 – 210 0/ c); - rotation angle sensor DUPUS-1 (measuring range ±3600); - flame temperature sensor DTP-1 (measuring range 100 – 11000 S).
MNIPI
Minsk
Produced in: Belarus, Minsk
Furnace control cabinet SHUP-100-1
Furnace control cabinet SHUP-100-1
Designation SHUP-100-1 Switching power, kW 100 Automatic switch, A 200 Supply network voltage, V/Hz 380
Produced in: Tula
NVDM-250 High vacuum Diffusion Pump
NVDM-250 High vacuum Diffusion Pump
The operation of the NVDM-250 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-250 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-250 open-type diffusion pump heater is a metal housing with a ceramic base laid in it with a heating element in the form of a spiral made of nichrome wire. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6 × 10-2 to 13.3 Pa (from 5 ×10-4 to 1 ×10-1 mmHg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 4°C to plus 25°C. The recommended cooling water consumption is 100+15 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mmHg) The level of the working fluid during operation, at which the parameters of the pump NVDM-250 are provided, must correspond to min 8mm, max 13mm. The volume of the filled working fluid is 0.55 l
Produced in: Kazan