Search

3959 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 552
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3959 products
NMR analyzer "FIANUMLAB"
NMR analyzer "FIANUMLAB"
Designed to study the petrophysical properties of rocks. Allows you to define: - Total porosity (Kp); - Pore size distribution (T2); - Calculated permeability. In the presence of a pyrolytic analyzer , FIANUMLAB calculates for rock samples: - Water saturation coefficient (Kv); - Oil saturation coefficient (Kn).
"FIANUM LAB"
Москва
Produced in: Moscow
COMBI-03M (MTM-01, VE-meter (50Hz Modification), P3-33M)
COMBI-03M (MTM-01, VE-meter (50Hz Modification), P3-33M)
from 339 000 ₽
The kit presents a full range of possibilities for measuring the magnetic field, industrial frequency fields of 50 Hz, microwave radiation.
Produced in: Moscow
Verification module PM-3
Verification module PM-3
The composition of the PM-3 verification module: Frequency comparator CHK7-1011; Universal frequency meter Ch3-86A; Universal voltmeter V7-79; Absorbed power wattmeter M3-108-2; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Generator of test pulses G9-1A; Oscilloscope S1-177; DC power supply B5-79/1; Electronic switchboard of RF signals; AC power source B2-7 (2 pcs.); PC, printer; Basic load-bearing structures (BNC). Technical specifications Measurement ranges of time-frequency parameters of signals: Continuous oscillation frequency from 0.005 Hz to 17.85 GHz Pulse repetition rate from 0.01 Hz to 100 MHz The carrier frequency of the IM signal is from 100 MHz to 17.85 GHz Pulse duration from 10 ns to 1000 s Time interval from 0 to 1000 s Nominal values of the frequency of the studied signals are 2,048; 5,0; 10,0; 10,24 MHz Measurement errors of time-frequency parameters of signals: Frequency of continuous oscillations ± (2,4·10-10 - 4·10-3) Pulse repetition rate ± (2·10-7 - 2·10-3) The carrier frequency of the IM signal is ± 2·10-7 Pulse duration ± (1 - 200) ns Time interval ± (1 - 200) ns The relative deviation of the frequency of the studied signal from the reference frequency ± (5·10-13 - 2·10-12) Frequency of continuous oscillations ± (3·10-11 – 1,1·10-5) Pulse repetition rate ± (2·10-11 – 6·10-5) Carrier frequency of the IM signal ± (3·10-11 – 1,1·10-5) Pulse duration ± (1·10-8 – 7,2·10-4) Time interval ± (2·10-10 – 7,2·10-4) Nominal values of the reference signal frequency ± (2·10-11 – 2,4·10-10) General technical characteristics: The area occupied by the module is 8-12 m2 Weight, not more than 327 kg Power supply voltage from 198 to 242 V frequency (50 ± 0.5) Hz Power consumption, no more than 2400 VA
Produced in: Moscow
Pure Hydrogen Generator GVCH-25D
Pure Hydrogen Generator GVCH-25D
from 300 000 ₽
The characteristics of the device are similar to the GVCH-12D model; the difference is in the absence of a reactor to remove traces of oxygen and the capacity, respectively, is 25 liters/hour (416 ml/min). Technical specifications Purity of hydrogen in terms of dry gas about 99.998% The concentration of water vapor at 20 OC and 1atm is not more than 10 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse ± 0.02 ati Maximum hydrogen capacity, reduced to normal conditions is 25 l/h The time of setting the operating mode, with the output turned off is no more than 20 minutes In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 25 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is not more than 0.04 l/hour Water consumption is 2.4 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average power consumption: in stationary mode is no more than 200 VA maximum (at startup) is no more than 250 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 16 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Exhaust cabinet LAB-1200 SHVF-N
Exhaust cabinet LAB-1200 SHVF-N
Table top: FRIDURIT 20mm Length, mm: 1238 Depth, mm: 726 Height, mm: 2100 equipment Working box front anti–spill side - TRESPA TopLab sink-drain (ceramics, internal size 250*95*112mm), pipe for water the package includes a siphon corrugated 2 flexible eyeliners with a length of 1200mm housing – melamine with a thickness of 16mm lifting screen with the possibility of fixing at any height – tempered glass with a thickness of 5mm, lifting 0-700mm, increase the height of the cabinet at full lifting by 450mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
 Yellow DPSS Laser 604 nm KLM-604-x
Yellow DPSS Laser 604 nm KLM-604-x
DPSS lasers of the KLM-604/x series are diode-pumped solid-state lasers of the visible spectral range (604 nm) with collimated continuous radiation of low and high power (depending on the model). The package includes: a laser head, a power supply, a set of connecting wires, a power cable and a device passport. Depending on the tasks, the following options are available for each laser model: the presence of TTL modulation / the presence of analog modulation, power control via the power supply, the presence of a display for the power supply, improved power instability (<3% / <1%), improved temporary power instability (4 h / 8 h), radiation sweep in-line (5...120°), laser head with fiber output (FC/SMA), extended warranty period, custom housing development. These lasers are widely used in medical equipment, for control and automation of technological processes, in scientific research, astronomy, spectroscopy. They are optimal sources of coherent radiation for the construction of systems of alignment and marking devices.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with sodium citrate 3.2%, 1.8 ml,13*75 mm, blue, glass, pack.100 pcs
Vacuum tube MiniMed with sodium citrate 3.2%, 1.8 ml,13*75 mm, blue, glass, pack.100 pcs
from 1 284 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Spring THERMOTEST holder-DP1-9/16
Spring THERMOTEST holder-DP1-9/16
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm. The design of the holder eliminates damage to glass thermometers. It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
Produced in: Tomsk
Exhaust cabinet LAB-M SHV 90.74.210 VI
Exhaust cabinet LAB-M SHV 90.74.210 VI
Furniture for laboratory work. Exhaust cabinet made of chipboard Working surface: VITE 16mm Overall dimensions: Length, mm: 900 Depth, mm: 740 Height, mm: 2100 equipment Working box front anti–spill side - acid–resistant polished stainless steel AISI 316 housing - white chipboard with a thickness of 16mm guide posts – aluminum profile painted with powder paint dark gray (RAL 7011) 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-710mm, do not change the dimensions of the cabinet when lifting.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
SPECTROMETERS MKS‑AT6101S, MKS‑AT6101SM
SPECTROMETERS MKS‑AT6101S, MKS‑AT6101SM
The best one in its class 20 hours of continuous operation Automatic simultaneous gamma-neutron radiation scanning with identification of radionuclides Permanent recording of GPS-linked scan data for subsequent analysis The possibility of expanding the measurement range of the ambient dose equivalent power to 10 Sv/h Software application "GARM" for expert data processing and analysis and radiation mapping The possibility of placing the spectrometer in a shockproof case (on request).
Produced in: Belarus, Minsk
PCR kits and mixes
PCR kits and mixes
from 2 100 ₽
Field of application: -Gene expression analysis -One-step standard RT-PCR -One-step standard RT-PCR and the use of fluorescent probes -One-step real-time RT-PCR with SYBR Green I fluorescent dye Advantages of use: -High specificity -High sensitivity -Easy and convenient to use -Low pipetting and cross-contamination errors -Standard conditions for the same type of reactions -The possibility of TA cloning of PCR products due to the amplified DNA fragments of deoxyadenosine residues protruding at the ends.
BIOLABMIKS
Novosibirsk
Produced in: Novosibirsk