Search

60 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 2
    Applying
  • Names
  • 5
    Manufacturer
  • 7
    Made in
  • 2
    Additional
View:
60 products
NVR-4,5D Plate-rotary vacuum pump
NVR-4,5D Plate-rotary vacuum pump
Pumping out steam-gas mixtures is allowed only when the gas-ballast device is open. The NVR-4,5D vacuum plate-rotary pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-006-00218526-2002, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity grid must meet the requirements of GOST 13109-97.
Produced in: Kazan
Pump PL.HM02.01.10 - vacuum combined membrane
Pump PL.HM02.01.10 - vacuum combined membrane
from 145 000 ₽
The diaphragm vacuum pump PL.HM02.01.10 has extremely high chemical resistance. The working chambers are made of fluoroplastic, and other parts have a fluoroplastic coating. Complies with protection class IP20. Uniqueness: The versatility of the pump allows you to connect the working chambers in three ways and thereby influence the technical characteristics.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum membrane pump PL.HM01.02.10 Primelab
Vacuum membrane pump PL.HM01.02.10 Primelab
from 150 000 ₽
The vacuum membrane pump PL.HM01.02.10 Primelab is designed for pumping steam-gas-air media, creating a vacuum, vacuum filtration and drying. The valves are made of FFKM, the chambers are made of fluoroplastic, all connecting elements and parts are coated with fluoroplastic. The pump has good performance despite its compact dimensions (321.5x160x200 mm). At a maximum pressure of 10 mbar it is capable of pumping up to 38 l/min. Does not require constant maintenance. Complies with IP20 protection class. It has a low noise level (up to 75 dB), which does not create discomfort for laboratory staff. Supplied complete with equipment sufficient for assembly and start-up.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
2NVR-250D Vacuum rotary vane pump
2NVR-250D Vacuum rotary vane pump
the 2NVR-250D vacuum pump is manufactured in the climatic version of UM 4 (i.e. for moderate climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). Electricity grid must meet the requrimemnts of GOST 13109-97. The 2NVR-250D vacuum rotary vane pump meets the requirements of technical specifications TU 3648-006-00218526-2002. The 2NVR-250D pump is refueled with VACMA OIL 100 power fluid. The level of the working fluid is monitored by the oil indicator, replenishment is needed when the level of the power fluid is below the minimum level of the oil indicator.
Produced in: Kazan
Vacuum combined chemical-resistant membrane pump PL.HM02 up to 10 or 50x2 mbar Primelab
Vacuum combined chemical-resistant membrane pump PL.HM02 up to 10 or 50x2 mbar Primelab
from 145 000 ₽
1 supp.
Characteristics Valve(s) material Standard: chloroprene copolymer NO-68-1 (TU 38 0051166-98) A country Russia Overall dimensions, L×W×H, mm 322x140x200 Protection class acc. to DIN EN60529 IP20 Noise level, dB 75 dBA Nutrition 230 V, 50 Hz Material working chamber PTFE (fluoroplastic) Ultimate vacuum, mbar abs. 10 for serial, 50 for parallel, 50x2 for independent connection Excess pressure, bar. Maximum permissible excess operating pressure 0.5 bar Productivity, l/min 76 with parallel, 38 with serial, 38x2 with independent connection Maximum current, A 1.2 Equipment Vacuum pump, cable, instructions, passport, packaging (vacuum regulator and spare parts are not included in the kit and must be ordered separately). Device weight, kg 8.6
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum membrane pump PL.HM04.02.01 Primelab
Vacuum membrane pump PL.HM04.02.01 Primelab
from 490 000 ₽
Vacuum membrane pump PL.HM04.02.01 PrimeLab is a compact laboratory device with which you can create a vacuum in the laboratory. It is equipped with innovative membrane technology that ensures high gas pumping speed. Suitable for pumping vapors and gases up to 1 mbar. The PL.HM04.02.01 pump has an excellent safety system. Protection against overheating and overload is provided. All contacting media are made of PTFE, which has rare chemical and physical properties. All control is carried out through vacuum control, which also ensures maximum accuracy and control of all operating parameters. It has a low noise level (75 dB), which does not cause discomfort to the working class.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
NVSp-35 Spiral Vacuum Pump
NVSp-35 Spiral Vacuum Pump
The NVSp-35 dry vacuum spiral pump can operate continuously at an inlet pressure of no more than 10 kPa (75 mm Hg), pumping out one or more sealed vessels with a total volume of no more than 3.5 m3 from atmospheric to residual pressure during the day. Pumping of vessels of the specified volume with leakage is allowed, but the leakage should not cause an increase in pressure at the pump inlet of more than 10 kPa (75 mm Hg).
Produced in: Kazan
NVDM-250 High vacuum Diffusion Pump
NVDM-250 High vacuum Diffusion Pump
The operation of the NVDM-250 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-250 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-250 open-type diffusion pump heater is a metal housing with a ceramic base laid in it with a heating element in the form of a spiral made of nichrome wire. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6 × 10-2 to 13.3 Pa (from 5 ×10-4 to 1 ×10-1 mmHg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 4°C to plus 25°C. The recommended cooling water consumption is 100+15 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mmHg) The level of the working fluid during operation, at which the parameters of the pump NVDM-250 are provided, must correspond to min 8mm, max 13mm. The volume of the filled working fluid is 0.55 l
Produced in: Kazan
LS-301 peristaltic pump
LS-301 peristaltic pump
Rotation speed range, rpm 0.1...200 Permissible outer diameter of the hose, mm 4...12 Number of pressure rollers 4 Adjustment error, rpm ± 0.5 Productivity, l/h 0.02...25 (when using a hose with an inner diameter of 5 mm) Power, W 100 Overall dimensions, mm 175x160x155 Weight, kg 5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum membrane pump PL.HM02.01.4 Primelab
Vacuum membrane pump PL.HM02.01.4 Primelab
from 250 000 ₽
1 supp.
The vacuum membrane pump PL.HM02.01.4 is a universal device made in Russia from the Primelab company. Made from high-quality materials, including fluoroplastic, used to create sealed chambers, and a protective coating for safe operation of the device. The technical characteristics of the pump depend on the method of connecting the chambers. With a series connection, the performance will be 38 l/min at a maximum vacuum of 4 mbar. Parallel and independent connections will allow you to achieve completely different performance indicators of the device. The vacuum diaphragm pump PL.HM02.01.4 Primelab is convenient to use. It has a light weight of 9 kg, compact dimensions (321.5x160x200 mm) and creates a minimum of noise (up to 75 dB).
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
NVDM-160 High-vacuum Diffusion Pump
NVDM-160 High-vacuum Diffusion Pump
The operation of the NVDM-160 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-160 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-160 closed-type diffusion pump heater consists of tubular electric heaters fixed in the heater housing. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6×10-2 to 13.3 Pa (from 5×10-4 to 1×10-1 mm Hg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 40C to plus 250C. The recommended cooling water consumption is 60+10 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mm Hg). The level of the working fluid during operation, at which the parameters of the NVDM-160 pump are provided, must correspond to min 10mm, max 17mm. The volume of the filled working fluid is 0.3 liters
Produced in: Kazan