Search

475 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 176
    Names
    Loading...
  • 40
    Manufacturer
    Loading...
  • Made in
  • 44
    Additional
    Loading...
View:
475 products
Device for automatic isolation of nucleic acids COLIBRI
Device for automatic isolation of nucleic acids COLIBRI
from 2 840 000 ₽
1 supp.
The open system allows you to work with reagents and laboratory plastics from various manufacturers Russian-language software Modifications: - COLIBRI 24 - the ability to select from 1 to 24 samples - COLIBRI 48 - the ability to select from 1 to 48 samples - COLIBRI 96 - the ability to select from 1 to 96 samples Range of working volumes: - COLIBRI 24 - 200 – 5000 mkl - COLIBRI 48 - 30 – 1000 mkl - COLIBRI 96 - 20 – 1000 mkl A unique format of consumable plastic - 8-hole strips and combs Two built-in thermostats The accuracy of temperature maintenance is ± 1 °C Heating/cooling - up to 100 °C / up to 35 °C Universal Thermostat Tube Unit Built-in computer Ready-made allocation protocols The time of one extraction cycle is from 11 minutes Built-in bactericidal UV lamp for interior treatment
SYNTOL
Москва
Produced in: Moscow
Magnetic Stirrer RITM
Magnetic Stirrer RITM
1 supp.
Technical specifications Supply voltage, V 220 Rated network frequency, Hz 50 Rotation speed range, rpm 300-1500 Overall dimensions, diameter/height, mm 125/50 Weight, kg 0,5 Stirrer housing Polypropylene Stirrer surface (chemically resistant material) Polypropylene Mixing volume, max, l 1 Operating conditions Ambient air temperature, °C 5 … 40 Relative humidity at 25 °C, % up to 90 Atmospheric pressure, kPa/mmHg. 84,0 … 106.7/ 630 … 800
Econix-Expert
Москва
Produced in: Moscow
rhIL-6
rhIL-6
from 6 600 ₽
Interleukin-6 is a cytokine that is secreted in response to infection or tissue damage and induces the production of proteins of the acute phase of inflammation, stimulates hematopoiesis and the immune response.
Produced in: Moscow
Metolab 101 Rockwell Hardness Tester
Metolab 101 Rockwell Hardness Tester
METOLAB 101 is an analog stationary hardness tester according to the Rockwell method, a modification of the METOLAB 100 hardness tester with an electromechanical loading system. The rest of the devices are identical. The stationary METOLAB 101 hardness tester is designed to measure the hardness of various materials using the Rockwell method, HRA, HRB and HRC scales. Due to its ease of operation, the stationary METOLAB 100 hardness tester can find its application in a wide variety of industries and production, as well as in educational institutions of various levels in the training of specialists. The stationary METOLAB 101 Rockwell hardness tester is included in the State Register of Measuring Instruments of Russia (GRSI) and comes with a certificate of primary verification (on request). The number in the GRSI is 65128-16. Distinctive features of the stationary METOLAB 101 Rockwell hardness tester: Simplicity and convenience in both operation and maintenance; Wide range of measured values; High degree of reliability; Low cost of measurements compared to competitors. Basic delivery package: Stationary METOLAB 101 hardness tester; Indenter with a ball (1.5875 mm) - 1 pc.; Conical diamond indenter (120°) - 1 pc.; Flat table SP1 (60 mm); V-shaped prismatic table SRP1 (40 mm); Rockwell hardness measures - 1 set; User Manual. Additional information: GOST standards and regulatory documents establishing requirements for the METOLAB 101 Rockwell hardness tester: GOST 8.064-94 GSI. State verification scheme for hardness measuring instruments on the Rockwell and Super-Rockwell scales; GOST 9013-59 Metals and alloys. Rockwell hardness measurement method. Scales A, B, C; GOST 22975-78 Metals and alloys. Rockwell hardness measurement method at low loads (Super-Rockwell); GOST 23677-79 Hardness testers for metals. General technical requirements.
Metolab
Moscow
Produced in: Moscow
Nitrogen Purification Units BOV-1A
Nitrogen Purification Units BOV-1A
from 69 600 ₽
They are designed for purification of nitrogen (BOV-1A) and air (BOV-1) from hydrocarbons Technical specifications Maximum nitrogen inlet pressure is not more than 410± 5% kPa (4 ati) Maximum allowable nitrogen consumption is no more than 350 ml/min The concentration of hydrocarbons in terms of methane in the input nitrogen is not more than 0.0025 %(25 ppm) The concentration of hydrocarbons in nitrogen at the outlet of the device at maximum flow is not more than about 0.00001 % (0.1 ppm) Ready time after switching on at a flow rate not exceeding the maximum value is no more than 30 minutes Power consumption is not more than 50 VA Overall dimensions, (width x depth x height) are not more than 185x310x310 mm Weight is not more than 5.0 kg Working conditions: ambient temperature, °C, from +10 to +35 relative humidity of the surrounding air, %, no more, at 35 °C 80 Electric power supply from a single-phase AC network with a voltage of 220 +10% -15% and a frequency of 50 ± 1 Hz
Produced in: Moscow
LAMPIX8 Portable instrument for real-time isothermal DNA amplification,  1 channel, 8×0,2 ml
LAMPIX8 Portable instrument for real-time isothermal DNA amplification, 1 channel, 8×0,2 ml
1 supp.
LAMPIX 8 uses the method of Loop-Mediated Isothermal Amplification of DNA and RNA (LAMP and RT-LAMP) for genetic analysis of any kind.
Key features.
  • Compact: supports 8 standard 200μL tubes in a single test run.
  • Portable:provides genetic testing in an on-site or mobile laboratory.
  • Fast: Result within 15 minutes after the start of the analysis.
  • Real-time: Detection of the results with our built-in software.
  • Open system: can work with any test kits with FAM / SYBR dyes for isothermal amplification.
  • Flexible: possibility to adjust settings for your research purposes.
LAMP TEST KITS: LAMP LYME KIT (Detection of the B.burgdorferi in ixodid ticks) *sensitivity from 50 copies of DNA. SARS-CoV-2 test (COVID-19).
Technical Specifications.
  • Excitation source 8 LEDs,
  • Excitation detection 8 photodiodes,
  • Number of Fluorophores 1 FAM/SYBR/EvaGreen,
  • Excitation wavelength 470 nm,
  • Detection range 510-530 nm,
  • Sample capacity 8 х 200 μl tubes,
  • Tube type separate tubes / strips with flat lid,
  • Operating temperature range 37˚C to 75˚C with 0.5˚C resolution,
  • Lid type heated lid,
  • Heated lid temperature range 37.0 ˚C to 75.0 ˚C with 0.5˚C resolution,
  • PC connection USB type С port,
  • Dimensions W × D × H 115 х 80 х 65 mm,
  • Weight 250 g,
  • Power 12 V / 18 W external power supply / power bank,
  • Software Operating system Win 7-10.
    Aivok
    Zelenograd
    Produced in: Moscow, Zelenograd
    NV-400 CHA Cabinet on wheels with 3 drawers (420*460*650)
    NV-400 CHA Cabinet on wheels with 3 drawers (420*460*650)
    from 7 154 ₽
    The NV-400 TV cabinet on wheels has 3 drawers. The facade of the cabinet has a shockproof PVC edge. The standard version of the cabinet on wheels for the laboratory table includes: 3 drawers on roller guides, shockproof PVC edge 2 mm, plastic wheel supports. In the standard version, we offer cabinets for laboratory tables in gray color. However, in agreement with the customer, it is possible to change the color to white, without increasing the cost. We are also ready to adapt the size and materials so that they meet your needs.
    NV LAB
    Moscow
    Produced in: Moscow, Moscow region
    NV-1500 LKv-Ya High laboratory table with drawers (1500×700×850)
    NV-1500 LKv-Ya High laboratory table with drawers (1500×700×850)
    from 21 359 ₽
    The NV-1500 LKv-Ya is a laboratory table on chipboard legs and with the table top made of granite tiles. The width of the table top is 1500 mm. The table is designed for standing work (table height: 850 mm) and is usually used for placing devices. There are two pull-out drawers for storing small stuff. The table top is made of granite tiles. The tile is moisture-resistant and perfectly withstands high temperatures. It is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. It has limited resistance to hydrofluoric acid. This is one of the most popular types of countertop materials for laboratory furniture. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table assembled (W×D ×H): 1500×700×850 mm. NV-1500 LKv-Ya Advantages of tables An inexpensive solution for laboratories that value the reliability and durability of furniture; Heating plates or baths can be placed on the granite surface resistant to high temperatures; It is convenient to work while standing: the height of the working surface is 85 cm; In the drawers you can store accessories to the devices that are on the table, or laboratory utensils. Application of NV-1500 LKv-Ya tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
    NV LAB
    Moscow
    Produced in: Moscow, Moscow region
    SHV NVK 900+ Fume cupboard with plumbing
    SHV NVK 900+ Fume cupboard with plumbing
    from 114 583 ₽
    The SHV NVK 900 KG+ fume cupboard with plumbing (900×716×2200). Description: Exhaust laboratory cabinets are used when working with toxic and harmful volatile materials, with clean materials, with dissolution or decomposition under heat treatment, during sample analysis and many others. The base of the cabinet is an all-welded metal frame in powder coating. The side laminated panels (chipboard with a thickness of 16 mm) are edged along the facade with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. Characteristics: Polypropylene sink with high chemical resistance; Chemically resistant brass faucet with polypropylene coating for cold water connection; Additional illumination on the side with smooth adjustment; A hood in the lower cabinet allows you to store reagents in it; Exhaust pipe on the cabinet lid with a diameter of 150 mm; Shock-resistant screen is easy to lift with one hand; The screen in the raised state does not increase the height of the cabinet; Inside the working chamber there is a shelf for storing reagents; Two moisture-proof sockets with a lid inside the working chamber; Special closers in the cabinet allow you to close the cabinet silently; On request, the countertops can be made of: chemical-resistant plastic porcelain stoneware (tile) polypropylene stainless steel monolithic ceramics epoxy expanded clay.
    NV LAB
    Moscow
    Produced in: Moscow, Moscow region
    Field strength meter small-sized microprocessor IPM-101M
    Field strength meter small-sized microprocessor IPM-101M
    Purpose: The device is designed to monitor compliance with the maximum permissible levels of high-frequency radiation (alternating electric field strength, alternating magnetic field strength and electromagnetic field energy flux density) at the workplaces of personnel servicing electrical and radio engineering installations and systems emitting an electromagnetic field, in accordance with GOST 12.1.006, GN 2.1.8./2.2.4.019 and San-PiN 2.2.4/2.1.8.055.
    Doza
    Zelenograd
    Produced in: Moscow
    Generator of test pulses G9-1A
    Generator of test pulses G9-1A
    The generator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as RS-232 and ITHERNET. Technical specifications The range of setting the pulse duration at the outputs: - τ1 from 100 ns to 10 s - t2 from 101 ns to 10.1 s - t3 from 10 ns to 3600 s The range of setting the time interval between the pulse fronts at outputs t1 and t2 (∆tx) is from 0 to 3600 s The main error in setting the pulse duration at outputs t1 and t2 ± (δ0 • t1,2 + 1•10-8 c) The basic error of setting the pulse duration at the output is τ3 ± (δ0 •τ3 + 2 •10-9 s) The main error in setting the duration of the time interval (∆tx): ∆tx from 0 to 1000 s ± (δ0 •∆tx + 2•10-10 s) ∆tx from 1000 to 3600 s ± (δ0 •∆tx + 2•10-9 s) Pulse amplitude at outputs τ1 , τ2 and τ3 at a load of 50 ohms, not less than 1.2 V The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator (δ0 ), no more than ± 2x10-7 in 24 months The pulse repetition frequency setting range at outputs τ4 and τ5 is from 0.1 Hz to 300 MHz The main error in setting the pulse repetition frequency at outputs τ4 and τ5 ± δ0 •F = τ4.5 Pulse amplitude setting range at outputs τ4 and τ5 from 0.05 to 1 V The main error in setting the pulse amplitude at outputs τ4 and τ5 ± 20% Fixed values of pulse durations at the output of τ6 1 and 5 microseconds The basic error of setting the pulse duration at the output is τ6 ± (0.2•τ6 + 3 •10-7 s) The nominal value of the pulse repetition frequency at the output is τ6 100 kHz The main error in setting the pulse repetition frequency at the output is τ6 ± δ0 •F = τ6 Fixed values of the pulse amplitude at the output of τ6 minus 10 V; minus 2.5 V; 2.5 V; 10 V The main error in setting the pulse amplitude at the output is τ6 ± 20% Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 442x160x452 Weight, not more than 10 kg
    Produced in: Moscow
    Installation radiometric UDGB-01
    Installation radiometric UDGB-01
    The installation provides continuous measurement, indication on the built-in indicator and transmission over the information network of the value of the volumetric activity of radioactive gases, including tritium and carbon-14. The detection units of the installation can be either built-in or remote. The installation is available in three versions: UDGB-01T, UDGB-1T1, UDGB-01T2, differing in metrological characteristics and design features. Purpose: measurement of the volumetric activity of beta-emitting inert gases (argon, krypton, xenon), as well as gases containing tritium and carbon-14 in the air of working rooms and ventilation systems.
    Doza
    Zelenograd
    Produced in: Moscow