Vacuum tube MiniMed with separation gel, 9 ml, 16×100 mm, red, PET, pack.100 pcs.
Vacuum tube MiniMed with separation gel, 9 ml, 16×100 mm, red, PET, pack.100 pcs.
from 1 650 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
ORB-1N POZIS recirculator
ORB-1N POZIS recirculator
from 15 924 ₽
Capacity, m3/h 100 Bactericidal efficiency, % 99.9 Total power of ultraviolet radiation of bactericidal lamps, W, not less 14.4 Service life of UV lamps, hours 9000 Power consumption, W, 62±10 Adjusted sound power level, no more than 40 dBA Bactericidal UV light lamp LUV 15W, with a power of 15W 3 pcs Dimensions (H*W*D), mm 886*366*163 Weight, kg, no more 7 Warranty, years 2 Approximate dimensions of the product with packaging Net weight of the product, kg 7 Gross weight of the product, kg 7,8 Volume of packaging, m3 0.068 Length of the package, m 0.92 Width of the package, m 0,41 The height of the package, m 0.18
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Sulfur and Nitrogen Analyzer SPECTROSCAN META
Sulfur and Nitrogen Analyzer SPECTROSCAN META
The analyzer allows you to determine the content of sulfur and nitrogen in oil and petroleum products (diesel fuel, gasoline, kerosene, gas oil and any distillate petroleum products), hydrocarbon gas, liquefied petroleum gas (LPG), natural gas, liquefied natural gas (LNG), chemical synthesis products, biological materials by ultraviolet fluorescence and chemiluminescence. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. There is a conclusion of the Ministry of Industry and Trade on the production of products in the territory of the Russian Federation. The analyzer is designed to determine: - mass fraction of sulfur in accordance with GOST ISO 20846-2016, GOST 34712-2021, GOST R 56866-2016, GOST 34237-2017, ASTM D5453-19, ASTM D6667-21, ASTM D7551-15, ISO 20729-17 ; - the mass fraction of nitrogen in accordance with ASTM D4629-17. A wide range of concentrations: from ultra-low to high. Modular principle: Each detector is a separate module. The device is equipped individually for each specific task. The possibility of simultaneous determination of sulfur and nitrogen in the analysis process. The principle of operation of the analyzer is to burn the test sample in an oxygen-enriched atmosphere or air at a temperature of 1050 ° C. The sulfur dioxide (SO2) and nitrogen oxide (NO) formed during combustion are transferred by carrier gas to the detection units with preliminary removal of water vapor, on the desiccant, and soot, on the filter. Determination of sulfur is carried out by ultraviolet fluorescence. Determination of nitrogen by chemiluminescence.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with K2-EDTA and separation gel, 1ml, 13×75mm, purple, glass, pack.100 pcs.
Vacuum tube MiniMed with K2-EDTA and separation gel, 1ml, 13×75mm, purple, glass, pack.100 pcs.
from 1 592 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with coagulation activator and separation gel, 3ml,13*100 mm, yellow-orange, glass,pack of 100 pcs.
Vacuum tube MiniMed with coagulation activator and separation gel, 3ml,13*100 mm, yellow-orange, glass,pack of 100 pcs.
from 1 339 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Material for research............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Biosafety cabinet BA-Safe 180
Biosafety cabinet BA-Safe 180
The Class II Type A2 biological safety cabinets are designed to reduce the risk of infection to the operator during work with dangerous or potentially dangerous microorganisms and to protect the specimen, is the result of the production of biological safety cabinets based on user feedback. Technical specifications Voltage, frequency, 230V ±10%/Hz Engine 1-phase 230 V, 50 Hz, speed 1150 rpm UV lamp TUV UV lamp, UV lamp timer, 6000 hours of operation Wavelength 254 nm Number of LEDs, pcs at least 380 Lighting power, 55 W Work area illumination at least 1500 lux, brightness adjustable, color of luminous flux 6000 K (cold white light) Internal dimension of the working area, at least 1830×504 mm Working height of front screen elevation, 200 mm Max. height of front screen elevation, 510 mm Frontal screen position alarm Audible position warning. Warning appears on display Outer dimension, mm 1968,5х766,2х1506,6 Height of base, mm 690
Produced in: Belarus, Minsk
Analyzer of sodium hypochlorite in water "AGH-3"
Analyzer of sodium hypochlorite in water "AGH-3"
1 supp.
Technical specifications: Output of results to digital display board, RS485, RS232; current loop 4-20 mA (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations is 20-200 g/l Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Relative humidity at + 25 °C 80 % Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +25 °C Ambient temperature from +5 to +35 °C Atmospheric pressure 87-107 kPa The warranty period of operation is 1 year Average service life of at least 3 years Dimensions - electronic block - optical unit no more than 300x400x150 mm no more than 120x90x90 mm Weight - electronic block - optical unit no more than 10 kg not more than 2 kg Power supply 187-242 V, 50 ± 1 Hz, from an autonomous source, 12V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with coagulation activator and separation gel, 5ml,13*100 mm, yellow-orange, PET,pack.100,
Vacuum tube MiniMed with coagulation activator and separation gel, 5ml,13*100 mm, yellow-orange, PET,pack.100,
from 1 210 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Material for research............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Pestle for homogenization 1.5-2.0 ml.
Pestle for homogenization 1.5-2.0 ml.
from 450 ₽
Pestles for homogenization For suspension in test tubes of 1.5/ 2.0 ml, 10 pcs. in the package Compatible with electromechanical drive for pestles Analog: SSI Material of manufacture: PP Packing: 10 pieces.
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
Mass spectrometer for the analysis of liquid samples "Lumas LIQUID"
Mass spectrometer for the analysis of liquid samples "Lumas LIQUID"
1 supp.
Technical specifications: ESI / APCI ionization method Time-of-Flight Mass Analyzer The maximum repetition frequency of the ejection pulses is 10 kHz Recording speed of spectra Up to 100 spectra per second Characteristics of a 12-bit ADC, 2 GHz The number of simultaneously defined components is unlimited Mass range 1-2000 m/z Resolution > 4000 Vacuum system of 2 Fornaps and 3 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with sodium heparin, 10 ml, 16×100 mm, green, PET, pack.100 pcs.
Vacuum tube MiniMed with sodium heparin, 10 ml, 16×100 mm, green, PET, pack.100 pcs.
from 1 755 ₽
Test tubes are used to count blood cells and study plasma parameters. When mixed with the collected material, heparin blocks the activity of thrombin and inhibits the transition of soluble fibrinogen to insoluble fibrin, inactivating the coagulation factors irreversibly. Material for research............... heparinized blood, plasma Scope of application............................ immunology, hematology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region