Pressure gauge MTIf-250
Pressure gauge MTIf-250
It is designed for the use with Raid bombs BR 01T, BR 02T in determining the absolute vapor pressure of volatile crude oil and volatile non-viscous petroleum products in accordance with GOST 1756. Pressure gauge with a range of measured pressure 0...250 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm Weight 1.5 kg
Produced in: Tomsk
QuattroPlex Chip multiplex analyzer, 1 x 20 ul in a disposable chip, with peripheral devices
QuattroPlex Chip multiplex analyzer, 1 x 20 ul in a disposable chip, with peripheral devices
1 supp.
QuattroPlex is the first Russian open multiplex platform for the quantitative and qualitative analysis of biomarkers by immunofluorescence analysis on magnetic beads. The detection technology copies the xMap technology, which allows analysis of several dozen analytes in a minimum volume. QuattroPlex benefits:
  • • Multiplexing - diagnostics of up to 50 markers in one sample in one analysis
  • • analysis of a wide range of markers (rheumatology, autoimmune diseases, HLA, cytokines, infections)
  • • open system - use of any test systems based on magnetic coded microspheres
  • • high sensitivity - possibility of qualitative and quantitative analysis
  • • design that requires minimal desktop space
  • • possibility of use in mobile laboratories.

Specifications:
  • • Registered size of microspheres, microns — from 0.5 to 100;
  • • 3 fluorescence registration channels;
  • • fluorescence excitation wavelengths, nm — from 380 to 850;
  • • wavelengths of fluorescence registration, nm — from 450 to 950;
  • • detector - CMOS matrix;
  • • sample volume, µl — from 30 to 60;
  • • number of test samples per load — 1 (in a chip);
  • • time for analysis of one sample, sec — 4;
  • • Results management and analysis software - QuattroPlex results management and analysis software, compatible with Win/Linux;
  • • interfaces for connecting to a laptop/PC — Internet/Wi-Fi;
  • • dimensions W×D×H, cm — 20×20×30.

Delivery set:
  • • system of multiplex analysis of biomarkers QuattroPlex;
  • • starter set of consumables;
  • • computer, keyboard, mouse and monitor.
Aivok
Zelenograd
Produced in: Moscow, Zelenograd
Sulfur Analyzer SPECTROSCAN SE
Sulfur Analyzer SPECTROSCAN SE
The analyzer is designed to determine the mass fraction of sulfur from 3 million-1 (ppm) in oil and petroleum products in accordance with GOST R 51947-2002, GOST 32139-2019, GOST R EN ISO 20847-2010 / GOST ISO 20847-2014, ASTM D4294, GB/T 17040-2019. Implements an arbitration method for measuring the mass fraction of sulfur for oil, automotive fuels of class K2, K3, jet engine fuel, aviation gasoline, fuel oil and marine fuel, and is also used for operational control of sulfur content in automotive fuels of Class 4 and 5, gas oils, bitumen, lubricating oils and their components and other petroleum products. The analyzer greatly simplifies the routine analysis procedure. Intuitive interface provides convenience and ease of use. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. Minimum operator actions: - calibration is selected and the name of the sample is entered; - two cuvettes are filled with a sample; - the obtained samples are placed in the analyzer and measurements are started; - all subsequent actions are performed automatically: - the average value of the mass fraction of sulfur is calculated and displayed; - repeatability is calculated; - the results are checked for compliance with the selected standard; - measurement results are printed on the built-in printer and saved.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Pressure gauge MTIf-100
Pressure gauge MTIf-100
Pressure gauge with a range of measured pressure 0 ... 100 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm
Produced in: Tomsk
Bath for the determination of paraffins BF
Bath for the determination of paraffins BF
The volume of the bath is 5 liters Overall dimensions 420x280x500 mm The open part of the bath is 230x235 mm Weight 7.5 kg
Produced in: Tomsk
Sulfur and Nitrogen Analyzer SPECTROSCAN META
Sulfur and Nitrogen Analyzer SPECTROSCAN META
The analyzer allows you to determine the content of sulfur and nitrogen in oil and petroleum products (diesel fuel, gasoline, kerosene, gas oil and any distillate petroleum products), hydrocarbon gas, liquefied petroleum gas (LPG), natural gas, liquefied natural gas (LNG), chemical synthesis products, biological materials by ultraviolet fluorescence and chemiluminescence. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. There is a conclusion of the Ministry of Industry and Trade on the production of products in the territory of the Russian Federation. The analyzer is designed to determine: - mass fraction of sulfur in accordance with GOST ISO 20846-2016, GOST 34712-2021, GOST R 56866-2016, GOST 34237-2017, ASTM D5453-19, ASTM D6667-21, ASTM D7551-15, ISO 20729-17 ; - the mass fraction of nitrogen in accordance with ASTM D4629-17. A wide range of concentrations: from ultra-low to high. Modular principle: Each detector is a separate module. The device is equipped individually for each specific task. The possibility of simultaneous determination of sulfur and nitrogen in the analysis process. The principle of operation of the analyzer is to burn the test sample in an oxygen-enriched atmosphere or air at a temperature of 1050 ° C. The sulfur dioxide (SO2) and nitrogen oxide (NO) formed during combustion are transferred by carrier gas to the detection units with preliminary removal of water vapor, on the desiccant, and soot, on the filter. Determination of sulfur is carried out by ultraviolet fluorescence. Determination of nitrogen by chemiluminescence.
NPO Spektron
Saint Petersburg