Laboratory scales VLTE-510S
Laboratory scales VLTE-510S
from 47 490 ₽
Technical characteristics: NIP, G510 Discreteness, g0,01 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.5 The price of the varification scale division, mg100 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 510g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Adjustment weight built-in Indication setting time, s, no more than~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-8201S
Laboratory scales VLE-8201S
from 154 990 ₽
Technical characteristics: NIP, G8200 Discreteness, g0,1 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5g to 5000g incl. ±500; sv. 5000g to 8200g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * ± 300 in the entire range The adjustment weight is built-in The time of setting the readings, s, no more than ~0.7 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
POWDIX 600 X-ray powder diffractometer
POWDIX 600 X-ray powder diffractometer
A feature of the POWDIX 600 X-ray diffractometer scheme is the vertical Bragg-Brentano optical scheme with a fixed horizontal sample position, which makes working with powdery materials, gels and other viscous substances more practical and convenient. The high detector resolution and precise positioning of the POWDIX 600 X-ray goniometer achieve an accuracy better than +/- 0.02° (2θ) over the entire angular range. In the POWDIX 600 diffractometer, the X-ray tube is cooled by an integrated closed water circuit, which can be serviced by any laboratory employee. A wide variety of sample holders (holder for massive samples, holder with rotation, phoneless cuvettes) expands the functionality of the POWDIX 600 and makes it an invaluable tool for scientific research in solid-state physics, materials science, chemistry, geology and other fields of science The diffractometer is included in the Russian State Register of Measuring Instruments.
Produced in: Belarus, Minsk
Radiation Monitoring Station Zastava-1
Radiation Monitoring Station Zastava-1
Devices of a new generation, automated stations of continuous radiation monitoring Zastava-1 are designed to organize continuous effective monitoring of the radiation situation and notification of radiation hazards. The stations have up to three independent measurement channels, which allows monitoring simultaneously in several zones. The stations support remote monitoring - they have a connection to a local computer network, Internet access.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Mercury monitor type RA-915AM for air analysis
Mercury monitor type RA-915AM for air analysis
1 supp.
Technical specifications: Ambient temperature, °C from +10 to +35 Relative humidity (at +25 °C), % no more than 98 Atmospheric pressure, kPa from 84 to 106.7 Power supply 220  22 V, 50  1 Hz Power consumption, VA no more than 150 Overall dimensions (LWC), mm Monitor Multiplexer 665x482x222 665x482x222 Weight, kg Monitor Multiplexer (2-16 channels) 25 15 - 25 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
UShS "Tapirus" with cover and supports
UShS "Tapirus" with cover and supports
from 18 000 ₽
The UShS TapiRus is designed to replace numerous templates and devices used in visual and measuring quality control of welded joints. It is approved as a means of measuring the geometric parameters of welded joints and surface defects during visual and measuring control (VIC) and supplied with verification. It allows you to determine most of the geometric parameters of welded joints and surface defects: the width and convexity of the seam, the depth of the cut, the amount of edge displacement, the angle of the angular seam, the angle of the bevel and the gap, etc. Equipped with supports that allow you to uniquely position the template on a curved surface. To carry out measurements with an error of 0.1 mm, scales with a vernier are applied to the TapiRUS surface. It contains a number of gauges for assessing the smooth transition from the deposited to the base metal, the size of the cathets, radii and angles of cutting edges. Equipped with a probe with a replaceable measuring needle to determine the size of gaps and heights / depressions. The development, preparation for production and manufacture of TapiRus were carried out exclusively in digital format. The latest laser and additive technologies are used in the production of TapiRUS: high-precision laser cutting machines in inert gas; five-axis CNC machining centers; ultra-precise color laser engraving of the entire product assembled; laser stereolithography (SLA) is a technology of layer–by-layer synthesis of a material from a liquid photopolymer. Advantages Easy to install. Accurate positioning along the normal to the surface of the object of control and stability of the position when performing measurements. Functionality. Measurement of most geometric parameters of welded joints and surface defects. Measurement accuracy. The measurement error on the template scales does not exceed 0.1 mm. Modernity. Online calculator ergonomic accessories smart version. More detailed information can be found on the website tapirus.info MEASURED PARAMETERS AND DEFECTS VIC at the stage of input control wall thickness depth of corrosion ulcers on the base metal the depth of corrosion ulcers on the weld the depth of scratches (risks), a bully on the base metal edge bevel angle the amount of blunting geometric parameters of the dent VIC during assembly (preparation for assembly) edge offset withdrawal (angularity) of edges the gap in the cutting the height of the potholders angular displacement VIC in the welding process (surfacing) edge offset height of the root (filling) layer withdrawal (angularity) of edges angular displacement VIC of finished welded joints (structures) edge offset angular displacement the height of the reinforcement of the seam the height of the bulge (when welding elements of different thickness) the width of the reinforcement of the seam withdrawal (angularity) of edges the depth of the sinking between the rollers incomplete filling of the cutting edges scaliness of the seam surface smooth transition undercut depth seam crater depth technical specifications Measured parameter Scale Range,mm Error, mm Depth, mm H 0...20 ±0.1 (in the range 0...10 on), ± 0.5 (in the range over 10...20) Height, mm H 0...6 ±0.1 Width, mm W 0...55 ±0.1 (in the range 0...10 on), ± 0.5 (in the range over 10...20) Clearance, mm N 0...5 ±0.1 Dullness, mm F, G 0...25 ±0.5 Specifications Overall dimensions, mm, no more (without supports) 115x85x15 ± 0.5 (with supports) 115x85x42 ±0.5 Average time to failure, cycles, at least 55,000 Weight, kg, not more than 0.22 Average service life, at least 1 year
Produced in: Moscow
VLA-220M comparator scales
VLA-220M comparator scales
from 359 990 ₽
Technical specifications NIP, g102/220 Discreteness, g0,00001/0,0001 Self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0,001 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.001g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * up to 102g ± 0.1; sv. 102g ± 0.3 The setting time, s, no more than ~ 6 /~1.5 Overall dimensions of the scales (LxWxH), mm411x212x345 7 years warranty Weight of the scales, kg, not more than 7.9 The weight adjustment is built-in
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
GC-MS CHROMATOGRAPH SYSTEM "CRYSTALLUX-4000M" WITH MSD "MAESTRO-AMC"
GC-MS CHROMATOGRAPH SYSTEM "CRYSTALLUX-4000M" WITH MSD "MAESTRO-AMC"
GC and MS interface Capillary direct interface, independent temperature control (50-300 0 S) The filament of the cathode (filament) is a double filament for electron ionization (EI), the maximum current is 300 µA. Double thread increases the service life. Two independent switchable cathodes Temperature of the ion radiation source Independent heating and temperature control, maximum value 350 0 C (adjustable) Transparent polymer window on the front panel there is no visual control of the state of the cathodes Ion radiation source Lenses made of ceramic and with a patented coating enhance the focusing effect, which significantly increases the efficiency of ionization, an electrode with a patented reflective surface improves focusing Tubular lenses enhance the focusing effect, which significantly increases the ionization efficiency, an electrode with a patented reflective surface improves focusing Energy ionization 10-100 eV The mass analyzer is a high-precision quadrupole with a filter that reduces the contamination of the main quadrupole and eliminates the influence of photonic noise on the analysis High-precision molybdenum quadrupole with prequadrupole (replaceable), which reduces the contamination of the main The detector is an electronic multiplier with a high-voltage secondary emiting electrode (dinode) of high energy 3D geometry to improve sensitivity. The amplifier of weak voltage signals effectively reduces network noise, improves the signal-to-noise ratio during electron ionization and provides a large linear dynamic range. It is possible to install an additional detector Mass range 2.0-1200 a.e.m. 1.5-1050 a.e.m. Mass stability Less than 0.1 a.e.m. for 48 hours Signal ratio noise At least 1500:1 with mass to charge (m/z) 272 At least 150:1 with mass to charge (m/z) 272 (with signal filtering 500:1) Linearity Not less than 107 Not less than 106 Precision < 5% RSD 9n=7, SIM, 100 fg OFN) no System sensitivity IDL < 10 fg (SIM mode, OFN according to m/z 272) no Maximum scanning speed 20000 a.m./s 11000 a.m./s Operating modes Scap, SIM, Scan/SIM, MicroScan and the innovative Flexible-SIM algorithm for finding trace amounts of components no Setting Automatic setting MSD on the PFTBA spectrum and m/z control of oxygen, nitrogen and water no Pumping pump Oil plate-rotor vacuum pump with a pumping speed of 66 l/min Oil plate-rotor vacuum pump with a pumping speed of 165 l/min Turbo pump Turbo molecular pump with magnetic levitation, with a pumping speed of 85 l/s (can be replaced by 300 l/s) Turbo molecular pump with magnetic levitation, with a pumping speed of 71 l/s (possible replacement by 260 l/s) RF detector power Allows you to use three points for calibration in the entire mass range and get good linearity in scanning mode Software Rus./ Eng. The ability to search and extract structural, graphical formulas. Library of 240,000 spectra. The ability to isolate individual components from overlapping peaks. In addition to spectra and compounds, the library contains the element name, formula, molecule structure, molecular weight, CAS number, analysis conditions, synonyms, and estimated or measured retention readings. The NIST EI library contains: drugs, metabolites and poisons, pesticides and fungicides, organic substances present in soil, water and air, amino acids, di- and tripeptides, common sample pollutants, common analytical derivatives, etc. Ethernet interface, remote access function implemented Touch screen Display of parameters and monitoring of system status no Built -in power supply Allows you to turn off the detector in normal mode if there is no power supply violation
Produced in: Yoshkar-Ola, Mari El
FT-805 IR Fourier spectrometer
FT-805 IR Fourier spectrometer
A small-sized IR Fourier spectrometer with integrated set-top boxes and two detectors, including a highly sensitive cooled MST. Operating modes: transmission and reflection, NIP, measurements using fiber-optic probes (possible versions with one or two pairs of built-in connectors). It is possible to connect an IR microscope, a telescope to register the spectra of external radiation. The spectrometer can be used as a portable one, and is used, among other things, for express monitoring of technological processes, quality control of liquids in tanks and pipelines, during in-line analyses of biological objects, remote gas analysis. The installation is designed to create high-quality images on various materials and provides the production of rubber cliche seals and stamps with a resolution of at least 1800 dpi. Description It was created on the basis of the innovative Shtrik platform, which is based on a unique control system, the hardware and software of which are entirely developed by specialists of our company. The installation is designed to create high-quality images on materials such as rubber, metal, plastic and provides the production of cliche seals and stamps with a resolution of at least 1800 dpi. The fiber laser used in the installation in combination with a system of galvanometric scanners ensures high quality engraving in static mode, does not require water cooling and special maintenance. When assembling the system, only tested and certified parts are used, which guarantees an especially long service life without additional investments. Features: A two-coordinate high-precision positioning system for samples, with the help of which the object table is moved along the X, Y axes. As a result of the positioning system and sequential engraving of image fragments, it is possible to process with high accuracy workpieces with dimensions up to 200 × 300 mm in automatic mode according to the processing program set by the operator; The algorithm of automatic layer-by-layer engraving using a high-precision mechanism for moving the scanning head along the Z-coordinate allows you to form highly detailed 3D images up to 5 mm deep in metal workpieces (steel, brass, aluminum, titanium, etc.); A long process of layer-by-layer engraving of deep 3D images (possibly tens of hours) is provided without operator involvement thanks to an automatic algorithm; The installation is equipped with a built-in system for removing combustion products from the laser radiation exposure zone, as a result of which, the absence of odors and protection of the scanning lens from the products of production is ensured, which is especially important when engraving rubber and plastics; The installation body completely covers the processing and propagation zones of laser radiation, and the engraving is performed according to the program set by the operator in automatic mode with the installation covers closed. This design of the installation allows it to be attributed to laser devices of hazard class 1.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Thermal Conductivity Detector(accident)
Thermal Conductivity Detector(accident)
It is used to determine hydrogen, oxygen, CO and combustible hydrocarbon gases, and its sensitivity to these compounds is higher than the sensitivity of an accident. The most widespread TCD was obtained for the analysis of hydrogen and oxygen, tk. its sensitivity to them is almost an order of magnitude higher than that of an accident. The principle of operation is based on fixing the thermal effect of catalytic combustion of the sample on the surface of the platinum filament. Technical characteristic: 1.8*10`10 g/ml of hydrogen
Produced in: Yoshkar-Ola, Mari El
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 87 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg