Search

137 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 1
    Additional
    Loading...
All filters
  • 22
    Areas of use
    Loading...
  • 55
    Item names
    Loading...
  • 17
    Manufacturer
    Loading...
  • 15
    Made in
  • Additional
    Loading...
View:
137 products
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-4M"
Liquid analyzer "FLUORAT®-02-4M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, not more than 0.005 Measurement range of the mass concentration of the control substance (phenol) in water, mg / dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ±2 Warm-up time, min, not more than 30 Continuous operation time, h, not less than 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, not more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, no more than 36 Operating time for failure, h, no less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
1 supp.
Technical specifications: Method of ionization Plasma pulsed glow discharge Discharge gas Argon, consumption less than 1 l/hour Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is unlimited Mass range 1-1000 m/z Detection limits 1-100 ppb Layer-by-layer resolution Up to 5 nm Depth of analysis Up to 30 microns The time for one analysis of a solid sample is 30 minutes (with the option of a revolver system – 3-5 minutes) Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg