VAC-12 platform scales
VAC-12 platform scales
from 65 990 ₽
Technical characteristics: NIP, KG12 Discreteness, g1,0 External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 12 kg ± 1.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 5KGF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-6100S
Laboratory scales VLTE-6100S
from 59 990 ₽
Technical characteristics: NIP, G6100 Discreteness, g0,1 Self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during initial verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 6100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Adjustment weight is built-in The setting time, s, no more than~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
VAC-101 platform scales
VAC-101 platform scales
from 69 990 ₽
Technical specifications NIP, kg101 Discreteness, g10 External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g500 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 500g to 50 kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 40kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-6202CI
Laboratory scales VLE-6202CI
from 204 990 ₽
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g1,0 The price of the verification scale division, mg100 The limits of the permissible error during the initial verification, mgot 1g to 5000g incl. ±50; sv. 5000g to 6200g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 30 in the entire range of the adjustment weight built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
VLA-220M comparator scales
VLA-220M comparator scales
from 359 990 ₽
Technical specifications NIP, g102/220 Discreteness, g0,00001/0,0001 Self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0,001 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.001g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * up to 102g ± 0.1; sv. 102g ± 0.3 The setting time, s, no more than ~ 6 /~1.5 Overall dimensions of the scales (LxWxH), mm411x212x345 7 years warranty Weight of the scales, kg, not more than 7.9 The weight adjustment is built-in
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-623S
Laboratory scales VLE-623S
from 129 990 ₽
Technical specifications: NIP, g620 Discreteness, g0,001 Calibrationsamocalibration The size of the scale bowl / platform, mm108x105 The smallest weighing limit, g0.02 The price of the calibration division, mg10 The limits of permissible error during primary verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 620g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * up to 50g ± 3; sv. 50g ± 5 The adjustment weight is built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-6202S
Laboratory scales VLE-6202S
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 6200g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * up to 500g ± 30; sv. 500g ± 50 The adjustment weight is built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-5100T
Technical laboratory scales VLTE-5100T
from 24 990 ₽
Technical characteristics: NIP, G5100 Discreteness, g1,0 External calibration Size of the scale bowl/platform, mm175x145 The smallest weighing limit, g50 The limits of permissible error during initial verification, mgot 50.0g to 5000g incl. ± 500; sv. 5000g to 5100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 2kgF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-1100
Laboratory scales VLTE-1100
from 59 990 ₽
Technical specifications: NIP, g1100 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 1100g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Adjustment weight 1kg F2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Platform scales ERW-52S
Platform scales ERW-52S
from 114 990 ₽
Technical characteristics: NIP, KG52 Discreteness, g1 Self-calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g5 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 5g to 5 kg incl. ±0.5; sv.5kg to 20kg incl. ±1.0; sv.20kg to 32kg incl.± 1.5 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than 3 The weight adjustment is built-in 5-year warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
VLA-135M comparator scales
VLA-135M comparator scales
from 499 990 ₽
Technical specifications NIP, g135 Discreteness, g0,00001 Self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0,001 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.001g to 50g incl. ± 0.5; sv. 50g to 135g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special Actual typical error limits of the scales, mg *± 0.1 in the entire range The setting time, s, no more than ~ 6 Overall dimensions of the scales (LxWxH), mm411x212x345 7 years warranty Weight of the scales, kg, not more than 7.9 The weight adjustment is built-in Price with VAT, RUB 359,990
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-410S
Laboratory scales VLTE-410S
from 74 990 ₽
Technical characteristics: NIP, G410 Discreteness, g 0.001 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the scale verification division, mg10 The limits of the permissible error during the initial verification, mgot 0.02 g to 50 g inclusive. ± 5; sv. 50 g to 200 g included. ±10; sv. 200 g to 410 g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg