It is designed for simultaneous polishing of four copper plates measuring 75×12.5×2 mm used in determining the corrosive effect of fuels in accordance with GOST ISO 2160, GOST 32329, GOST 6321, GOST 2917 and ASTM D130.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
It is designed to accommodate six cylinders for hydrometers with a diameter of up to 54 mm in thermostats VT-ro-01, VT-ro-02 or CRYO-VT-ro-03. A basket with a height-adjustable bottom allows the cylinders to be immersed in the coolant to the required depth.
Number of jobs 6
Weight 1.1 kg
It is designed to be placed in a liquid thermostat CRYO T 05 01 and is used to determine the turbidity temperature and the beginning of crystallization of motor fuel in accordance with GOST 5066 (method B).
For testing, an additional set of CRYO T 05 01 K devices is required.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
The stopper holder is made of Teflon. It allows you to mount securely the temperature sensor of the LT 300 or LT electronic thermometers in 14/23-sized laboratory glassware.
It is used for determining the turbidity or fluidity temperature of petroleum products in accordance with EN 23015 and ASTM D97.
For testing, additional sets of devices BNTI 05 04 K and BNTI 05 04 3K are required.
A set of devices is used to determine the oil content in oil paraffins in accordance with the State Standard 9090 and is intended for placement in a liquid bath BNTI 05 04.
The spring holder for LT 300 or LT electronic thermometers allows you to simply and securely mount the temperature sensor on the walls of laboratory utensils so that it does not touch either its bottom or the wall.
This allows temperature measurements to be carried out not only conveniently, but also correctly.
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is used in determining the flow temperature of petroleum products in accordance with GOST 20287 (method A).
For testing, additional sets of devices BNTI 05 04 K and BNTI 05 04 3K are required
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
It is used to connect TDS thermometers and MASTER thermostats equipped with an RS 485 interface to a personal computer via a USB interface.
The use of this adapter does not require the installation of additional drivers because it uses the HID driver built into the operating system to exchange data.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.