The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
It is designed to be placed in a liquid thermostat CRYO T 05 01 and is used to determine the turbidity temperature and the beginning of crystallization of motor fuel in accordance with GOST 5066 (method B).
For testing, an additional set of CRYO T 05 01 K devices is required.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is used for determining the turbidity or fluidity temperature of petroleum products in accordance with EN 23015 and ASTM D97.
For testing, additional sets of devices BNTI 05 04 K and BNTI 05 04 3K are required.
The spring holder for LT 300 or LT electronic thermometers allows you to simply and securely mount the temperature sensor on the walls of laboratory utensils so that it does not touch either its bottom or the wall.
This allows temperature measurements to be carried out not only conveniently, but also correctly.
It is used in determining the density of petroleum products, resins, plasticizers and other chemical products by hydrometers in stainless steel cylinders with a height of 300 mm and internal diameters of 60.5 and 73 mm.
It is used to determine the corrosive effect of petroleum products on a copper plate in accordance with GOST ISO 2160, GOST 32329, GOST 6321 and GOST 2917.
It is used in determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 5066 (Method B) and GOST 18995.5.
It is intended for placement in the BF bath and is used in determining the mass fraction of paraffins in oil in accordance with the method A of the State Standard 11851.
It is intended for placing vessels with samples in the working baths of the BNTI 05 04 bath when determining the low-temperature properties of petroleum products, if appropriate test vessels are available.
Suitable for placing vessels with samples for the State Standard 20287 (Method A), EN 23015 or ASTM D97.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
It is used to connect TDS thermometers and MASTER thermostats equipped with an RS 485 interface to a personal computer via a USB interface.
The use of this adapter does not require the installation of additional drivers because it uses the HID driver built into the operating system to exchange data.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
Designed for devices of the SF, Minigem, Specord series when operating in the spectral range from 260 to 2500 nm. Chemically resistant to acids (except hydrofluoric acid) and dilute alkalis.
It is designed to be placed in a liquid thermostat CRYO T 05 01 and is used to determine the turbidity temperature and the beginning of crystallization of motor fuel in accordance with GOST 5066 (method B).
For testing, an additional set of CRYO T 05 01 K devices is required.
The basket with a lid is designed to accommodate unambiguous measures of electrical resistance in the MT-21 thermostat during their verification and calibration in accordance with GOST 8.237.
Internal dimensions 103x170 mm
Weight 0.3 kg