Muffle furnace LF-9/13-V1
Muffle furnace LF-9/13-V1
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; The door opens up and faces the user with the cold side; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x150x290 mm Overall dimensions, WxHxD, not more than 525x1015x620 mm Rated supply voltage, 220 V Rated power, W 5500
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with manual control SNVS-25/3.5
Vacuum drying cabinet with manual control SNVS-25/3.5
from 289 144 ₽
The SNVS-25/3.5 vacuum drying cabinet with a volume of 25 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 350 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options. Marking SNVS-25/3.5 volume,L 25 temperature,oS 350 vacuum, mmHg 10 type of vacuum pump oil plate-rotary
Produced in: Tula
PL-1818 Heating plate
PL-1818 Heating plate
The size of the heating surface: 180x180 mm. Heating temperature: 40-400 °C.
Produced in: Tomsk
Educational laboratory complex KUL-1
Educational laboratory complex KUL-1
It is intended for use in higher and secondary educational institutions during laboratory workshops on training specialists in engineering and technical specialties and natural science disciplines. Technical specifications: Upost.- 0.1 mV - 500 V; Uperem.- 1 mV-300 V (40 Hz-20 kHz) Ippost. - 0.1 mkA- 2 A; Iperem. - 1.0 mkA - 2 A (40 Hz-1 kHz) Rpost. - 0.1 Ohm – 20 mOhm Generation of triangles, pilobr., "meander", sinusoid. signal in the frequency range 0.1 Hz – 1 MHz Frequency measurement in the range of 0.1 Hz – 1 MHz The form of the measured signals is sine, pulse Constant voltage: at a current of 1 A - + 5 V at a current of 0.5 A for each channel - ± 12 V Adjustable Uppost. at a current of up to 1 A - 0 – 30 V Dimensions - 170x340x380 mm Power supply – 230 V, 50 Hz, 200 VA - max. Weight – 8.0 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
LP-630 Flow Vacuum Trap
LP-630 Flow Vacuum Trap
The LP-630 flow-through water trap is installed on the inlet flange of the diffusion pump and is designed to reduce the flow of working fluid vapors into the pumped volume by condensing them on the cooled elements of the freezing device.
Produced in: Kazan
Liquid thermostat THERMOTEST-05
Liquid thermostat THERMOTEST-05
Operating temperature range -80...+30 °C. The stability and uniformity of the temperature in the working bath is not worse than ± 0.02 ° C without the use of a leveling unit. Bath volume 15 l Overall dimensions 800x500x1220 mm The open part of the bath is 90 mm Bath depth 430 mm Weight 115 kg Power consumption 4.2 kW
Produced in: Tomsk
Immersion thermostat circulator LT-400
Immersion thermostat circulator LT-400
Designed to maintain the set temperature of objects in the bath, as well as for thermostating external systems: laboratory reactors, measuring cells of refractometers, viscometers, electrochemical analyzers, etc. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, (l/min) 6...12 pressure, (bar) 0,4 The working fluid is water, silicone oil. Dimensions, mm 115x240x305 Weight, kg 5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Mobile laboratory for 0.4-35 kV cable lines (ETL-35)
Mobile laboratory for 0.4-35 kV cable lines (ETL-35)
Laboratory equipment for 0.4-35 kV cable lines (ETL-35) 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 100 kV. 2. Burning facility • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low-voltage cables); • – Built-in afterburning. 3. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 4. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 5. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where the pipeline and cable intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method.
Produced in: Kolomna, Moscow region
LB63-Sh Laboratory bath
LB63-Sh Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is +5...+200 °C. Six workstations with a diameter of 110 mm with five steel O-rings, tripods and feet with a clip. Stamped steel tub with a volume of 25 liters and a depth of 160 mm. The volume of the bath is 25 liters Overall dimensions 570x660x710 mm The open part of the bath is 500x290 mm Bath depth 160 mm Weight 16 kg Power consumption 2.5 kW
Produced in: Tomsk
Laboratory drying cabinet SNOL-F-67/500-I2
Laboratory drying cabinet SNOL-F-67/500-I2
from 242 777 ₽
The laboratory drying cabinet SNOL-F-67 is designed for thermal testing, aging, as well as drying, tempering and other types of heat treatment of various materials in an air environment at temperatures up to 500 ° C with natural or forced air convection in stationary conditions.
Produced in: Tula
Cable Searcher Athlete AG-324
Cable Searcher Athlete AG-324
The Athlete AG-324 cable searcher is a combination of the modern American Ridgid SR-24 track finder receiver and the most powerful multi-frequency portable generator AG-120T in the line of TECHNO-AC generators.
Produced in: Kolomna, Moscow region
Correlational leakage detector Iskor-210
Correlational leakage detector Iskor-210
from 395 370 ₽
Designed for: – determining the location of leakages from pipelines by the correlation method; – tracing underground utilities; – clarification of the leak location by an acoustic leak detector; – creation of an information database on the condition of pipelines and the results of pipeline diagnostics; – search for the place of damage to the power cable by induction and acoustic methods.
Produced in: Kolomna, Moscow region