DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT110
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT110
Irradiator with a typical collimator Rotary drum magazine sources in tungsten and lead protection Software control of the movement of sources and positioning of the mobile platform An alarm and blocking system, radiation monitoring system to ensure the safety of the installation Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk
Mobile Substation Laboratory TECHNOAS
Mobile Substation Laboratory TECHNOAS
The TECHNOAS substation laboratory consists of: Test facility • – Maximum rectified voltage up to 70 kV to 90 mA. • – Maximum AC voltage of the industrial frequency of 50 Hz to 100 kV to 175 mA. The IDP-10 dielectric loss meter unit is based on the Tangent-2000 meter and includes: • – Power transformer parameter meter. • – Measurement of losses and current XX. • – Measurement of short circuit losses and voltage. • – Determination of the transformation coefficient and the winding connection group. • – Measurement of the resistance of the windings to direct current. • – Formation of the test report. A milliohmmeter Measures DC resistance in inductive and non–inductive circuits in the range of 1 µΩ ÷ 10 kΩ at a current of 10A, as well as makes oscillograms of switching the contactor of a high-speed RPN device.
Produced in: Kolomna, Moscow region
Set of devices for CRYO-T-05-01 the State Standard 20287 method B
Set of devices for CRYO-T-05-01 the State Standard 20287 method B
It is used for determining the pour point of petroleum products in accordance with GOST 20287 (method B).
Produced in: Tomsk
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
▪ Measurements without sampling in geometry 4π ▪ Intelligent detection unit in an airtight container ▪ The possibility of further detailed processing of the measured data using specialized software
Produced in: Belarus, Minsk
Muffle furnace LF-7/13-G2
Muffle furnace LF-7/13-G2
Design features: Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set temperature, temperature change rates and exposure time; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Backlit graphic display; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x285 mm Overall dimensions, WxHxD, not more than 505x565x655 mm Rated supply voltage, V 3300
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Knapsack installations for manual cutting of steel RU-1 (M1)
Knapsack installations for manual cutting of steel RU-1 (M1)
from 70 688 ₽
The purpose of this installation is manual cutting of steel sheets and objects of similar hardness (for example, building structures, grilles, doors) using acetylene and oxygen in emergency situations. The installation is manufactured for climatic performance of UHL category I according to GOST 15150-69, but for operation at ambient temperatures from minus 25 ° C to plus 50 ° C.
Produced in: Tula
Richter Absorber Primelab (high-speed)
Richter Absorber Primelab (high-speed)
1 supp.
Richter absorber PrimeLab (high-speed) is a laboratory device for high-speed purification and absorption of gases. Its design consists of two spherical extensions. Two tubes are soldered into the top one: gas is released along the long one for purification, and through the second it comes out in a purified form. A high-speed Richter absorber was produced by Primelab from borosilicate glass. This determines the vessel’s ability to withstand the influence of different temperatures, strength and long service life. Does not react with chemically active substances. Thanks to transparency, you can observe all processes inside the vessel.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum tube MiniMed with lithium heparin, 6 ml, 13×100 mm, green, PET, pack.100 pcs,
Vacuum tube MiniMed with lithium heparin, 6 ml, 13×100 mm, green, PET, pack.100 pcs,
from 804 ₽
Test tubes are used to count blood cells and study plasma parameters. When mixed with the collected material, heparin blocks the activity of thrombin and inhibits the transition of soluble fibrinogen to insoluble fibrin, inactivating the coagulation factors irreversibly. Material for research............... heparinized blood, plasma Scope of application............................ immunology, hematology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
PKV-IP-11×5.5
PKV-IP-11×5.5
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications the length of the waveguide, mm 11×5.5 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 17.44-25.96 VSWR 1.25
Produced in: Moscow
BENCH SK-ST, SK-ST
BENCH SK-ST, SK-ST
from 11 010 ₽
The bench is intended for use in changing rooms of industrial enterprises, medical institutions, educational institutions and other facilities. The design is based on a painted steel profile and a seat made of HPL-plastic. The materials used ensure the strength and durability of the product, are not afraid of moisture, and are suitable for sanitization with disinfectants. SK-ST Width – 1000 SK-ST Width – 1200
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
Grille on the back wall of LAB-PRO RZP-SHVOS 15
Grille on the back wall of LAB-PRO RZP-SHVOS 15
Number of horizontal rods: 3 rods 1230mm long Number of vertical rods: 3 rods 1000mm long rods (d=10mm) – polished stainless steel AISI 304 rod holders – duralumin rod clamps – screws-M-4 lambs (stainless steel AISI 304) it is possible to install horizontal rods in the required position
LOIP
Saint Petersburg
Produced in: Saint Petersburg