Connecting device UP-4
Connecting device UP-4
Technical specifications: Residual capacity when working with immitance meters < 1 pF Residual inductance when working with immitance meters < 0.5 µgn Residual resistance when working with immitance meters < 0.05 ohms Maximum input voltage ±60 V Distance between measuring contacts from 0 to 6 mm Length 1050 mm Weight 160 g
MNIPI
Minsk
Produced in: Belarus, Minsk
Oxygen meter MARK® 303 T
Oxygen meter MARK® 303 T
Convenience and accuracy of measurement | Automatic temperature and barocompensation, air oxygen calibration. Measurement modes | KRK and temperature. IP65 | Compact sealed device is reliably protected from dust and moisture. Non-volatile electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software included | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format, ease of settings. Long-lasting sensor | Sensor service life of at least 10 years. Low power consumption | Up to 600 hours of continuous operation from a set of AA elements. Designed for "operational" monitoring | "Fast" sensor – the measurement time is no more than 3 minutes. Illumination for work in darkened rooms. Record measurements at the touch of a button. Self-diagnosis | Additional guarantee of correct operation of the device
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Laboratory container for sampling sterile 60 ml with screw. roofs.and a spoon, p / p, ind.pack. / box.400 pcs.
Laboratory container for sampling sterile 60 ml with screw. roofs.and a spoon, p / p, ind.pack. / box.400 pcs.
from 2 160 ₽
Provides complete tightness during transportation of biological material. The material of the container is polypropylene, the lid with a spoon is polyethylene. It has a graduated and frosted window for recording. Sterile.
MiniMed
Suponevo
Produced in: Bryansk region
Specialized vacuum electric furnace for annealing VOZH-2,5-25
Specialized vacuum electric furnace for annealing VOZH-2,5-25
B – vacuum; The coolant furnace is designed for annealing; 2.5 – the volume of the working space in dm3; 25 – the maximum operating temperature divided by 100, i.e., 2500 ° C
VakETO
Mosrentgen
Produced in: Moscow
Table-sink LAB-M MO 80.65.90 F20
Table-sink LAB-M MO 80.65.90 F20
Furniture for laboratory work. Table-sink LAB-M MO 80.65.90 F20 Width, mm: 800 Depth, mm: 650 Height, mm: 900 Equipment: Table top – monolithic laboratory ceramics FRIDURIT 20 mm (one-piece seamless glazed plate without a rim, color light gray) 1 built–in bowl - FRIDURIT ceramics. The location of the bowl in the center, the mounting of the bowl is overhead. Inner bowl size – 400*400*250 mm The base of the sink table is a support pedestal made of white melamine Facades – laminated MDF of white color with a thickness of 16 mm, dark gray ABS edging Without shelves
LOIP
Saint Petersburg
Produced in: Saint Petersburg
MAESTRO-αMS gas chromatograph by Interlab
MAESTRO-αMS gas chromatograph by Interlab
We offer expert laboratories of physicochemical methods of analysis a gas chromatograph with a quadrupole mass spectrometric detector «MAESTRO-αMS». Quadrupole GC-MS «MAESTRO-αMS» is in demand for targeted research (screening) and non-targeted search. In targeted studies, it is necessary to detect given target compounds in samples of various nature and origin at the level of residual amounts, for example, several picograms of the target compound in the injected 1 μl of liquid sample. Most often, targeted research is carried out in the following areas of laboratory screening: ecology, food safety, clinical monitoring, narcology, doping control, production control of various raw materials. In targeted studies, it is often required not only to confirm the presence of a compound in a sample, but also to determine the level of its content quantitatively, since both the list of target compounds and the permissible level of their presence in the sample are specified by regulatory documents. Quantitative analysis requires standards for the substances you are looking for. When conducting a non-target search, as a rule, it is required to analyze a sample of unknown composition, in other words, to find as many compounds as possible in the sample and identify (identify) each of them. Since the identification of a detected compound is carried out by comparing its experimental mass spectrum with the spectrum of a pure substance obtained under standard conditions, this task requires reference libraries of mass spectra of pure substances, as well as tools for working with mass spectra, for example: algorithms for cleaning experimental mass spectra from background and spectral noise (mass spectrum deconvolution algorithms), library search and comparison algorithms. An off-target search is called a qualitative analysis, since the researcher is primarily interested in the list of detected substances, and not in the quantitative assessment of their content in the sample. When creating MAESTRO-αMS, we took into account our own many years of experience in operating imported analogues. We have made the device inexpensive. We have made the device compact: The modern design of the device made it possible to make the MAESTRO-αMS really compact, so that the device occupies the smallest possible area on the laboratory table. The layout of the device allows you to remove the ion source on the front flange for cleaning and replacing the cathodes, if necessary. We have reduced the cost of operation: When developing the MAESTRO-αMS, we sought to increase the resistance of the device to sample matrices and use a minimum of consumable materials in order to eliminate downtime for maintenance and replacement. As a result, we have created an extremely stable ion source and a perpetual photomultiplier detector. We have created special software: Even at the first acquaintance with the software, it becomes obvious that being in the window of each button and each parameter to be changed is expedient and logical. Our software product was created for the convenience of the operator, so we implemented the necessary and eliminated the unnecessary. We used the principle of one active window, in which the operator moves sequentially step by step, performing hardware settings, setting the data collection method, subsequent processing algorithms, templates for presenting the results. MAESTRO-αMS offers a wide range of scanning modes, built-in algorithms for working with mass spectral data, convenient unloading of initial data arrays for their processing in specialized software packages, graphics export for presentations and scientific publications. You can use several libraries of mass spectra at the same time, or create your own for your typical tasks. Finally, we provide a 5-day training course for professionals who want to understand the theoretical foundations of the method and their implementation in the hardware of modern quadrupole GC/MS. The volume and depth of presentation of the material from the developers of the device is intended to lay the foundation for the effective use of «MAESTRO-αMS» in the future. Some technical characteristics of MAESTRO-αMS: • Instrumental detection limit (SIM, OFN @272 m/z ) < 10 fg; • Scan modes: scan for selected ions, full scan in a given mass range, combined scan mode; • The number of simultaneously connected libraries of mass spectra is at least 10.
Produced in: Moscow
Blue DPSS Laser 470 nm KLM-470-x
Blue DPSS Laser 470 nm KLM-470-x
DPSS lasers of the KLM-470/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes. Technical specifications Radiation output power: up to 20W Radiation wavelength: 470 nm Output beam diameter: 1.5mm Divergence of the radiation beam: 1.3 mrad Instability of radiation power: 5% Type of modulation: TTL or analog Time to enter the mode: 15min Spectral line width: 0.1nm
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
DC power supply B5-79/1
DC power supply B5-79/1
The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET Technical specifications Output voltage setting range from 0 to 60 V Output current setting range from 0.2 to 10 A Electrical output power, not less than 300 W The main error of the output voltage setting is ± 100 mV The main error of the output current setting is ± 100 mA Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 1 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 5 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 2 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 5 mA) Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mV Instability of the output current for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mA Operating temperature range from 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 240x128x313 Weight, not more than 6.0 kg
Produced in: Moscow
Tracing generator AG-114.1
Tracing generator AG-114.1
from 94 530 ₽
The automatic tracer pulse generator "AG-114.1" is designed to create propagating signals (vibrations) in the routes of hidden communications with the active method of tracerouting. The device creates an alternating sinusoidal current in the studied communication (constantly or in short-term parcels) necessary to determine its location. The features of the AG-114.1 generator The selected output power (5 W at 1...1000 ohms, 10 W at 1...500 ohms, 20 W at 1...250 ohms) is issued automatically. The ability to work on such high load resistances allows you to trace very extensive communications. Low power provides energy saving and small "readjustments" to neighboring objects, high power provides a high range of broadcast and detection. Three generation modes: pulse – the main high-efficiency mode with high intelligibility against the background of interference; continuous – an additional low-cost mode for short-term special measurements; three–frequency mode, which provides the selection of the optimal frequency on a remote receiver without switching the transmitter (generator). Three generation frequencies: 512 Hz, 1024 Hz, 8192 Hz. Lower frequency – less "readjustment" to neighboring objects, higher frequency – higher detection range. Unusually compact (190x140x80 mm), for such a high output power (20 W), the autonomous design is provided by the use of highly efficient technology "CLASS D (BD)" (pulse output power amplifier with an efficiency of 80%). As a result, one small-sized autonomous battery with a capacity of only 2.2 Ah provides pulse generation for >5 hours at maximum output power (20 watts). It is possible to work with "recharge" from the charger or increase capacity by connecting an external battery to increase the time resource.
Produced in: Kolomna, Moscow region
PRN-3050-2.2 Heating plate
PRN-3050-2.2 Heating plate
Laboratory heating plate with glass-ceramic surface and two independent heating sections. The size of the heating surface: 300x500 mm. Heating temperature: up to 450 °C. It has two modifications: with built-in and remote control unit.
Produced in: Tomsk
Circulation thermostat LT-105P
Circulation thermostat LT-105P
Technical specifications: Temperature range: without external cooling, °C Current+10 ...+100 with tap water cooling °C Tvods+5 ...+100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, 0.17 bar Bath volume, l 5 The working fluid is water, water-glycerin mixture. Open part of the bath / depth, mm 110x150/150 Overall dimensions, mm 180x330x320 Weight, kg 4.4
LOIP
Saint Petersburg
Produced in: Saint Petersburg