Search

3995 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 37
    By name of foreign product
    Loading...
  • 522
    Names
    Loading...
  • 3995
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3995 products
CAPACITOR PARMA KGI-10-100
CAPACITOR PARMA KGI-10-100
Appointment For use in measuring: · capacitance and tangent of the dielectric loss angle of high-voltage insulation (capacitors, inputs, transformers, insulators) · characteristics of partial discharges of liquid dielectrics in laboratory and field conditions, complete with an insulation parameter meter (for example, PARMA TENSOR-2)
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Laboratory LAB table-900 LTv
Laboratory LAB table-900 LTv
equipment side decorative panels – melamine 16mm thick all-welded frame made of rectangular metal profile painted with white powder paint adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with K2-EDTA and separation gel, 5 ml, 13×100mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA and separation gel, 5 ml, 13×100mm, purple, PET, pack.100 pcs,
from 902 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed without filler, 4 ml, 13×100 mm, red, glass, pack.100 pcs
Vacuum tube MiniMed without filler, 4 ml, 13×100 mm, red, glass, pack.100 pcs
from 964 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
ND-250 High-vacuum diffusion pump
ND-250 High-vacuum diffusion pump
The working condition of the ND-250(P) diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-250(R) diffusion pump is a maximum of 1.8 liters, a minimum of 1.3 liters. The viewing window for visual inspection of the working fluid has labels of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid almost does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-250(R) diffusion pump using the same temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the pump up to 320˚C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 160 l/h, for the oil reflector it is 20 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-TB 120.74.230 KG
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-TB 120.74.230 KG
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. AISI 304 steel rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – tempered glass in an aluminum frame on the top panel: 4 anti-explosion valves LED dust- and moisture-proof lamp (2x10W IP65) is separated from the workspace by tempered glass thickness of 4mm flange d=250mm (distance from rear panel to the center of the flange – 170mm) switching box with automatic emergency power off 16A easily removable exhaust visors 3 levels of exhaust on the rear panel: technological hole d = 60mm with a plastic plug counterweights are placed in the front pillars-pylons and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather front pillars - aluminum profile painted with powder paint (RAL 7035/RAL 5023) adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Tracing generator AG-114.1
Tracing generator AG-114.1
from 94 530 ₽
The automatic tracer pulse generator "AG-114.1" is designed to create propagating signals (vibrations) in the routes of hidden communications with the active method of tracerouting. The device creates an alternating sinusoidal current in the studied communication (constantly or in short-term parcels) necessary to determine its location. The features of the AG-114.1 generator The selected output power (5 W at 1...1000 ohms, 10 W at 1...500 ohms, 20 W at 1...250 ohms) is issued automatically. The ability to work on such high load resistances allows you to trace very extensive communications. Low power provides energy saving and small "readjustments" to neighboring objects, high power provides a high range of broadcast and detection. Three generation modes: pulse – the main high-efficiency mode with high intelligibility against the background of interference; continuous – an additional low-cost mode for short-term special measurements; three–frequency mode, which provides the selection of the optimal frequency on a remote receiver without switching the transmitter (generator). Three generation frequencies: 512 Hz, 1024 Hz, 8192 Hz. Lower frequency – less "readjustment" to neighboring objects, higher frequency – higher detection range. Unusually compact (190x140x80 mm), for such a high output power (20 W), the autonomous design is provided by the use of highly efficient technology "CLASS D (BD)" (pulse output power amplifier with an efficiency of 80%). As a result, one small-sized autonomous battery with a capacity of only 2.2 Ah provides pulse generation for >5 hours at maximum output power (20 watts). It is possible to work with "recharge" from the charger or increase capacity by connecting an external battery to increase the time resource.
Produced in: Kolomna, Moscow region
2NVBM-250/3000 Booster high vacuum pump
2NVBM-250/3000 Booster high vacuum pump
The 2NVBM-250(R)/3000 booster pump consists of housings, a steam pipe, a trap and a heater. The alignment of the steam line in the pump housing 2NVBM-250(R)/3000 is carried out by a steam line screed, which, when installing the housing on the collector, enters its upper end into the hole of the hood (oil reflector). The required effective speed of action of the forevacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the 2NVBM-250(R)/3000 booster pump is not less than 25 l/s. The maximum residual pressure of the 2NVBM-250(R)/3000 pump measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6 × 10-4 Pa (5 × 10-6 mm Hg). The pressure of the cooling water at the inlet to the 2NVBM-250(R)/3000 pump should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2). The drain from the pump must be free with a jet break. Cooling water consumption is 360 l/h. The total amount of working fluid for the 2NVBM-250(R)/3000 pump is 17 liters, the level of the working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1 · 10-2 to 1 · 10-1 mm Hg). The operating mode of the pump in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
Universal calibrator H4-24
Universal calibrator H4-24
The main field of application of the calibrator is the verification of measuring instruments. The calibrator is capable of operating both independently and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 and ETHERNET. Technical specifications Ranges of reproduction of electrical quantities: - constant electrical voltage from 0 to 1000 V - alternating electric voltage in the frequency range from 10 Hz to 70 kHz from 0.9 mV to 1050 V - alternating electric voltage in the frequency range up to 100 kHz up to 750 V - alternating electrical voltage in the frequency range up to 1 MHz to 110 V - the power of direct electric current from 0 to 2 A - the power of alternating electric current in the frequency range from 10 Hz to 10 kHz from 0.9 µA to 2 A - electrical resistance of 1, 10, 100 ohms, 1,10,100 kOhm, 1,10,100 mOhm Errors in the reproduction of electrical quantities: - constant electrical voltage ± (0.0012 – 0.003)% of U + (0.0003 – 0.015)% of Up - alternating electric voltage in the frequency range from 10 Hz to 1 MHz ± (0.007 – 0.3)% of U + (0.001 – 0.25)% of Up - DC current ± (0.004 – 0.007)% of I + (0.001 – 0.01)% of Ip - AC electric current in the frequency range from 10 Hz to 10 kHz ± (0.015 – 0.1)% of I + (0.002 – 0.1)% of Ip - electrical resistance ± (0.002 – 0.005)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 480x200x550 Weight, not more than 35 kg
Produced in: Moscow
VD-7.2×3.4
VD-7.2×3.4
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Flange type according to GOST RV 51914-2002 Frequency range, GHz 25.95-37.50 VSWR 1.25 Losses, dB 2.0 Length, mm* 500
Produced in: Moscow