LAB-1600 TK Titration table
LAB-1600 TK Titration table
Furniture for laboratory work. Titration table Working surface: Porcelain stoneware (the surface directly under the rack is TRESPA Athlon 8mm) Length, mm: 1600 Depth, mm: 600 Height, mm: 900(1800) EQUIPMENT rack support racks – aluminum profile painted with powder paint (RAL 1001) the top panel of the rack with a depth of 190mm – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
ND-630 High-vacuum diffusion pump
ND-630 High-vacuum diffusion pump
The working condition of the ND-630 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (uner technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-630 diffusion pump is a maximum of 9 liters, a minimum of 6 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-630 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-630 diffusion pump up to 360°C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 600 l/h, for the oil reflector it is 80 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
Tracing generator AG-120TM
Tracing generator AG-120TM
from 238 050 ₽
The AG-120TM generator is designed for localization and diagnostics of underground utilities (cables, pipelines). The maximum power of the generator is up to 300 watts (depending on the selected operating mode). The device has no equal in the qualitative indicator of the ratio: power-resource-dimensions-weight. Application of the AG-120TM generator To trace communications by electromagnetic method (cables, metal pipelines) and acoustic method (metal and non-metallic pipelines). To carry out a highly efficient search for cable damage sites. Carry out diagnostics of gas pipelines and determine the places of damage to the insulation of protective coatings. Work with any receiver due to the possibility of selecting any operating frequency in the range of 200-10000 Hz. Features of the AG-120TM generator Increased battery capacity compared to the AG-120T generator. Automatic matching for a given current in the load, instead of the output power, allows you to get the predicted signal level at the input of the search receiver. The multi-frequency (200-10000 Hz) multifunctional device can be equipped with any search receiver using this frequency range. Automatic selection of output power by an “intelligent” power selection program. The built-in “output multimeter” shows the voltage, current, resistance and power in the load. High output current (up to 15 A) makes it possible to work efficiently on “low-resistance” (up to short-circuit) loads (for example, grounded pipelines). High output voltage (220 V auto./330 V with complement. battery) allows you to effectively trace “high-resistance” long-range communications. Multifunctionality: operation without direct connection with a resonant transmitting antenna, inductive pliers, a shock mechanism and an isolation monitoring sensor. Ability to work in rainy weather (on/off; viewing parameters with the lid closed).
Produced in: Kolomna, Moscow region
Table-sink LAB-M MO 120.65.90 T6F
Table-sink LAB-M MO 120.65.90 T6F
Furniture for laboratory work. Table-sink LAB-M MO 120.65.90 TF Width, mm: 1200 Depth, mm: 650 Height, mm: 900 Equipment: Table top – TRESPA TopLabPlus is a monolithic slab of ultra–high pressing thickness of 6mm with a chemically resistant surface made of polyurethane-acrylic composition, on a substrate of wood-containing material (plywood 15mm or melamine 16mm), edged around the perimeter with a PVC edge of 2mm 1 built–in bowl - FRIDURIT ceramics. The location of the bowl in the center, fixing the bowl flush with the level of the countertop. Inner bowl size – 400*400*250 mm The base of the sink table is a support pedestal made of white melamine Facades – laminated MDF of white color with a thickness of 16 mm, dark gray ABS edging Without shelves
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted table LAB-1200 PKT
Wall-mounted table LAB-1200 PKT
EQUIPMENT rack support racks – aluminum profile painted with powder paint (RAL 1001) top panel with a depth of 190mm – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Adsorption dryers with cold regeneration
Adsorption dryers with cold regeneration
The Provita company offers adsorption dryers with cold and hot regeneration of its own production. Industrial installations are equipped with high-quality components that ensure reliability and long service life. They are capable of operating at a pressure of 4 to 16 bar and are drained to a TRD (dew point under pressure) of -70 ° C. Working pressure: 4 — 16 bar Dew point: -20 to -70°C Capacity: from 50 to 5000 m3/hour
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with sodium citrate 3.2%, 3.6 ml,13* 100 mm, blue, PET,pack.100 pcs.
Vacuum tube MiniMed with sodium citrate 3.2%, 3.6 ml,13* 100 mm, blue, PET,pack.100 pcs.
from 693 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Research material............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Automatic apparatus for determining the flash point in an open crucible TVO-LAB-12
Automatic apparatus for determining the flash point in an open crucible TVO-LAB-12
Technical specifications: Flash temperature measurement range 0...400°C Heating speed 0.5...20°C/min The ignition period is 0.5...10°C Igniting a gas flame Flash/ignition ionization sensor Power consumption from AC 220V, no more than 700 watts Overall dimensions 405x340x265 mm The weight of the device is 12 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-416b
Circulation thermostat LT-416b
The LOIP LT-416b modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a lean-to hinged lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 16 The working fluid is water, silicone oil. Open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x400 Weight, kg 12.9
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Cylinder 1-100-2 with spout and glass base.
Cylinder 1-100-2 with spout and glass base.
from 237 ₽
Designed for dispensing volatile liquids. The applied scale of brown or white colors is completely resistant to any influences. TU 9464-013-52876351-2014, GOST 1770-74, pack.6/96 pcs, MiniMedProm Manufactured according to TU 9464-013-52876351-2014 in accordance with the technical requirements of GOST 1770-74. The products are made of chemical laboratory glass according to GOST 21400. Execution 1, accuracy class 2. RU No. RZN 2016/4740 of 10/25/2021
MiniMed
Suponevo
Produced in: Bryansk region
Aquadistillator electric DE-140
Aquadistillator electric DE-140
from 312 000 ₽
Purpose: obtaining distilled water of 3 types according to GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Capacity: 140.0 (-10%) l/h Heating elements: electrodes The quality of the produced water GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Type of current, frequency, voltage: alternating three-phase, 50 Hz, 380 V Power consumption: 84.0 kW Overall dimensions (L×W×C), mm: 810×630×1420 Weight: 87 kg Warranty period: 12 months from the date of sale Registration certificate for a medical device No. FSR 2008/03707 dated December 05 , 2008 Electrical conductivity of the produced water: 3-4.5 microns/cm Produced water temperature: 50 °C Source water flow rate (at 10 °C water temperature): 1000 (+-10%) l/h Source water pressure: 01,-0.4 MPa Overall dimensions of the control unit (L×W×C), mm: 400×220×500 Execution: outdoor Coefficient of water purification from radionuclides: at least 4000 Service life: at least 8 years
Livam
Belgorod
Produced in: Belgorod
Stand THERMOTEST-100-P
Stand THERMOTEST-100-P
The stand provides convenience when taking measurements, allowing you to set the thermometers at eye level. Designed for calibration thermostat THERMOTEST-100. Overall dimensions 400x625x490 mm
Produced in: Tomsk