Laboratory work table high LAB-PRO SLv 120.65.90 KG
Laboratory work table high LAB-PRO SLv 120.65.90 KG
Laboratory work desk Table top: KG (porcelain stoneware) Length, mm: 1200 Depth, mm: 650 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Contact thermometer TK-5.01PS
Contact thermometer TK-5.01PS
from 14 904 ₽
The digital contact thermometer TK-5.01PS is designed to measure the surface temperature of solids by direct contact of the probe with the measuring object. The digital contact thermometer consists of an electronic unit and a non-replaceable surface probe. Thermoelectric converters (TP) with NSH according to GOST R 8.585 are used as a thermosensitive element in the probe.
Explosion-proof vacuum electric furnace START-25
Explosion-proof vacuum electric furnace START-25
Vacuum resistance furnaces are necessary for heating products before pressure treatment, for sintering, degassing, quenching, annealing, soldering and chemical-technological processes. Such furnaces among all the variety of thermal equipment are considered the most environmentally friendly – heat treatment is carried out at t up to +2500 ° C in a purified vacuum. Under certain conditions, vacuum furnaces are used to work with neutral gases. The outer part of the furnace is made of stainless steel and is cooled by liquid. The inner part of the working chamber, where the heat treatment of materials is carried out, is made of an alloy of molybdenum and tungsten. The components are characterized by a low inertia force, reduced gas separation. The settings are available on the control panel, where the instruments, automatic and manual control switches are located. At every enterprise of the electronic industry, nuclear power, an explosion-proof vacuum resistance furnace is needed. The same applies to areas where various products undergo heat treatment at the stage of production and preparation for use.
Produced in: Tula
Serological pipette 25 ml.,sterile,ind.pack.,pack.50 pcs./box.200 pcs.,p/s,
Serological pipette 25 ml.,sterile,ind.pack.,pack.50 pcs./box.200 pcs.,p/s,
from 2 250 ₽
The pipettes are serological, disposable, made of crystalline polystyrene. Sterilized by gamma radiation. The color marking encodes the corresponding denomination according to international standards. Pipettes are apyrogenic, do not have hemolytic and cytoxic effects. The calibration on the pipettes is applied with black, abrasion-resistant paint. Pipettes of all denominations have a negative overflow scale, continuing the main scale.
MiniMed
Suponevo
Produced in: Bryansk region
Immitance Broadband Analyzer E7-28
Immitance Broadband Analyzer E7-28
Technical specifications: Extended frequency range 25 Hz–10 MHz The basic error is ±0.1 % The level of the measuring signal is 5 mV – 1 V S.K.z. Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Furnace for heating in a protective environment CHO (3)-6/11
Furnace for heating in a protective environment CHO (3)-6/11
from 1 420 750 ₽
Designation SNO(H)-6/11 Power, kW, no more than 8 Supply network voltage, V 380 Frequency, Hz 50
Produced in: Tula
VL-220M comparator scales
VL-220M comparator scales
from 274 990 ₽
Technical specifications NIP, g82/220 Discreteness, g0,00001/0,0001 Self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0,001 The price of the calibration scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.001g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * from 1mg to 10mg ± 0.2; from 10mg to 82g ± 0.1; sv. 82g ± 0.3 The setting time, seconds, no more - fast mode - 8/3; - standard mode - 10/6 Overall dimensions of the scales (LxWxH), mm356x220x338 7 years warranty Weight of the scales, kg, not more than 7.6 The weight adjustment is built-in
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
TPZ-LAB-12 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-12 is a built–in cooling unit capable of cooling the test cell to -85 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests to determine the temperature of turbidity and solidification, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 4.5 ml Temperature range of the test cell -85...+51°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 250 W Overall dimensions 315x470x405 mm Weight 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Table-sink LAB-M MO ME 120.65.90 T6F
Table-sink LAB-M MO ME 120.65.90 T6F
Furniture for laboratory work. Washing table on a metal support stand LAB-M MO ME 120.65.90 T6F Width:1200 Depth: 650 Height: 900 Equipment: Table top – TRESPA TopLabPlus - a monolithic slab of ultra-high pressing thickness of 6 mm with a chemically resistant surface made of polyurethane–acrylic composition, the lining material is moisture-resistant plywood 15 mm thick; the table top is edged with a dark gray plastic edge 1 built–in bowl - FRIDURIT ceramics. The location of the bowl in the center, fixing the bowl flush with the level of the countertop. Inner bowl size – 400*400*250 mm The base of the sink table is a metal support pedestal. All-welded frame painted with dark grey powder paint RAL 7011. The bottom and top of the housing are sheet steel painted with dark gray powder paint RAL 7011, the side walls are made of sheet steel painted with white powder paint RAL 9016. Facades – laminated MDF of white color with a thickness of 16 mm, dark gray ABS edging
LOIP
Saint Petersburg
Produced in: Saint Petersburg
NVDM-160 High-vacuum Diffusion Pump
NVDM-160 High-vacuum Diffusion Pump
The operation of the NVDM-160 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-160 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-160 closed-type diffusion pump heater consists of tubular electric heaters fixed in the heater housing. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6×10-2 to 13.3 Pa (from 5×10-4 to 1×10-1 mm Hg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 40C to plus 250C. The recommended cooling water consumption is 60+10 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mm Hg). The level of the working fluid during operation, at which the parameters of the NVDM-160 pump are provided, must correspond to min 10mm, max 17mm. The volume of the filled working fluid is 0.3 liters
Produced in: Kazan
Measuring antenna P6-62
Measuring antenna P6-62
1 supp.
Technical specifications: Frequency range (300-1000) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 400x145x150 mm Weight 1 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
Measurements in wide ranges of capacities doses and energies Measurement of dose rate and duration of exposure during short-term radiation from 0.03 s Measurement of the average dose rate of pulsed radiation with a pulse duration of 10 ns (AT1123) The possibility of remote measurements using a remote control The possibility of stationary location with external audible and visual alarms with "dry" contacts for controlling actuators The possibility to connect to a PC for organizing a continuous monitoring system with a documentation function
Produced in: Belarus, Minsk