Search

3995 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 37
    By name of foreign product
    Loading...
  • 522
    Names
    Loading...
  • 3995
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3995 products
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-4
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-4
Tracing a cable line. Burning of defective cable insulation with subsequent afterburning of it. Troubleshooting of cable lines by induction method. Troubleshooting of cable lines by acoustic method. Insulation testing of power cables and solid dielectrics.
Produced in: Kolomna, Moscow region
Laboratory electronic thermometer LTA/C-B
Laboratory electronic thermometer LTA/C-B
Accuracy ± 0.02 °C in the range 0...+100 ° C, built-in electronic stopwatch. The minimum immersion depth of the sensor is 75 mm Overall dimensions 80x75x100 mm Weight 0.25 kg Battery power 2 AAA size cells with a total voltage of at least 2 V
Produced in: Tomsk
Correlational leakage detector Iskor-219
Correlational leakage detector Iskor-219
from 547 170 ₽
Designed for: – determining the location of liquid leakages from pipelines by the correlation method; – tracing underground utilities with the display of the communication axis and digital measurement of the depth of occurrence; – clarification of leakage sites by acoustic leak detector; – search for the place of damage to the power cable by induction and acoustic methods; • – creation of an information database of the condition of pipelines and the results of pipeline diagnostics.
Produced in: Kolomna, Moscow region
Island LAB table-3000 OTM
Island LAB table-3000 OTM
equipment 2 countertops sink-drain (polypropylene, internal size 250*100*150mm), laboratory faucet d/water the package includes a siphon corrugated hose flexible eyeliner length 1200mm 2 racks, each support racks – aluminum profile painted with powder paint (RAL 1001) top panel 190mm deep – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Cruciform connectors
Cruciform connectors
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
Vacuum tube MiniMed with separating gel, 5 ml, 13×100 mm, red, PET, pack.100 pcs,
Vacuum tube MiniMed with separating gel, 5 ml, 13×100 mm, red, PET, pack.100 pcs,
from 1 571 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Automatic installation of LK-500 for distillation of c by Kjeldahl
Automatic installation of LK-500 for distillation of c by Kjeldahl
Technical specifications: Reagent volume setting range, ml 0 ... 200 The range of setting reaction and distillation times, min 0 ... 60 Steam power setting range, %30 ... 100 Average distillation time of the sample, min 2 ... 4 Water consumption for cooling, l/min 5 Power consumption from the mains 220 V, W 2200 Overall dimensions, mm 460x370x760 Weight, kg 35
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LB22 Laboratory bath
LB22 Laboratory bath
It is designed for thermostating samples in glasses, flasks and other laboratory utensils in cases when high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Two workstations with a diameter of 110 mm with five steel O-rings. Stamped steel tub with a volume of 5 liters and a depth of 110 mm. The volume of the bath is 5 liters Overall dimensions 385x205x310 mm The open part of the bath is 295x145 mm Bath depth 110 mm Weight 7 kg Power consumption 2.5 kW
Produced in: Tomsk
DOSIMETERS DKG‑AT2140, DKG‑AT2140A, DKG‑AT2140A/1
DOSIMETERS DKG‑AT2140, DKG‑AT2140A, DKG‑AT2140A/1
A small-sized economical device for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation. A unique combination of economy, speed and usability Working time without replacing batteries (2 x AA): AT2140 - 5000 hours, AT2140A, A/1 - 10000 hours Search mode USB interface and software for configuring the dosimeter and viewing the measured information (AT2140A/1)
Produced in: Belarus, Minsk
Water bath WB-4
Water bath WB-4
Temperature setting range, oC +35…+95 Temperature error, oC ±1.0 is protected from excess temperature RAINBOW TSR-150S F-C Hydraulic thermostat Supply voltage, V 230+-10% Current consumption 3.3 A Power consumption, 750 W Overall dimensions L x W x H, mm 380 x 300 x 190 Overall dimensions of the bath L x W x H, mm 290 x 300 x 140 Total/ engine capacity, 12.0/9.0 l
Produced in: Belarus, Minsk
Verification module PM-9
Verification module PM-9
The composition of the PM-9 calibration module: Universal voltmeter calibrator H4-12 (2 pcs.); Variable voltage calibrator H5-5A; A measure of the stress ratio H4-8; AC voltage voltmeter VK3-78A; Generator-calibrator of harmonic signals SK6-122; The meter-calibrator of the harmonic coefficient SK6-20A; AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-2; The measure of DC electrical resistance is multi-valued MS3055; Decadal high-resistance resistance magazine M-109R; Single-digit electrical resistance measures MS3080 (0.001; 0.01; 0.1 ohms); Electrical resistance measures unambiguous MS3050M (1, 10, 100, 1000, 10000, 100000 Om); The measure of electrical resistance is unambiguous P4013; The measure of electrical resistance is unambiguous P4023; The measure of electrical resistance is unambiguous P4033; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage DC from 1 MV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 10 mV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Harmonic coefficient in the frequency range of 10 Hz ... 200 kHz from 0.001 to 100 % Ranges of reproduction of electrical quantities: Constant electrical voltage DC from 1 nV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 3 MV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 1 MHz ... 2000 MHz from 3 MV to 3 V DC electric current from 1 µA to 20 A The power of alternating electric current in the frequency range from 0.1 Hz to 10 kHz from 1 µA to 20 A Electrical resistance from 0.001 ohms to 11 ohms Harmonic coefficient in the frequency range from 10 Hz to 200 kHz from 0.001 to 100 % Measurement errors of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage, in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 1.2) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.2 ... 6.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.0008 ... 2.0) % Errors in the reproduction of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 4.0) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.6 ... 10.0) % DC power ± (0.0033 ... 0.5) % The power of alternating electric current in the frequency range from 10 Hz to 10 kHz ± (0.055 ... 1.0) % Electrical resistance ± (0.001 ... 1.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.006 ... 2.0) % General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 430 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 2000 VA
Produced in: Moscow
rhNog
rhNog
from 17 000 ₽
Nojin is a protein involved in the development of various tissues, including bone, muscle and nerve. It is an antagonist of bone morphogenetic proteins (MBPs). Noggin has been implicated in a number of pathological conditions.
Produced in: Moscow