Smart air probe L=1000 mm SSV.1000P with built-in flash memory
Smart air probe L=1000 mm SSV.1000P with built-in flash memory
from 14 214 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object The smart air probe L=1000 mm SSV.1000P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.1000P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.1000P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
“SP-10 Lab” ultrasonic bath by SpetsmashSonic
“SP-10 Lab” ultrasonic bath by SpetsmashSonic
Bath name: UZK-10; Body overall dimensions, mm: 400x265x390; Working capacity size: 300x240x200; Basket size: 225x175x150; Volume, l: 10; Power, W: 570; Ultrasound power, W: 260;
Produced in: voronezh
Universal frequency meter Ch3-86A
Universal frequency meter Ch3-86A
The frequency meter is capable of operating both independently and as part of automated measuring systems with an interface such as USB, RS-232 or IEEE-488 (CPC). Technical specifications Frequency and period of sinusoidal and video pulse signals (input A) 0.005 Hz - 100 MHz Frequency of sinusoidal and video pulse signals (input to) 0.01 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (0.6 - 17.85) GHz Pulse duration 10 ns - 10000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from 0 to 10000 s The frequency ratio of the two signals is up to 109 The average value of the carrier frequency of the pulse-modulated (IM) signal (input D) (0.6 - 17.85) GHz Frequency measurement resolution 2x10-10 s/Rng Phase difference of two synchronous sinusoidal signals from minus 180° to 180° Measurement error of the phase difference of two synchronous sinusoidal signals ± 0.36° (from 1 kHz to 1 MHz)±3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 30 MW - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •inputs C, D (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz; 220 V, 400 Hz Power consumption, no more than 50 VA Overall dimensions, mm 229x136x435.5 Weight, not more than 7.5 kg
Produced in: Moscow
Vacuum tube MiniMed with K2-EDTA and separation gel, 5 ml, 13×100mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA and separation gel, 5 ml, 13×100mm, purple, PET, pack.100 pcs,
from 902 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Apparatus for dispersing petroleum products
Apparatus for dispersing petroleum products
Technical specifications: Acceleration temperature up to 400°C Supply voltage 220 V Power consumption, no more than 750 watts Overall dimensions 450x450x535 mm Weight 20 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Voltmeter V7-82
Voltmeter V7-82
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± 0.01% AC voltage , Measuring range, 1 mV - 700 V Measurement error, ± 0.4% Frequency range, 20 Hz- 1 MHz Direct current , Measuring range, 0.2 µA - 10 A Measurement error, ± 0.15%
MNIPI
Minsk
Produced in: Belarus, Minsk
Monoblock liquid cooling unit MCHV-5
Monoblock liquid cooling unit MCHV-5
from 216 640 ₽
Designation MCHV-5 Cooling capacity at Two.water= +15C, Tcond=+45C, Current.cp.=+30C, kW 5 Required pump capacity, m3/h 1,2 Pressure loss in the heat exchanger, kRa 30
Produced in: Tula
Smart submersible reinforced probe  L=1000 mm SZPGU.1000
Smart submersible reinforced probe L=1000 mm SZPGU.1000
from 850 770 ₽
The smart submersible reinforced probe L=1000 mm SZPGU.1000 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPGU.1000 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPGU.1000 smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Induction vacuum electric furnace IVP-17—17- In
Induction vacuum electric furnace IVP-17—17- In
The furnace provides a bottom drain, a device for mixing, the possibility of directional crystallization
VakETO
Mosrentgen
Produced in: Moscow
Vacuum tube MiniMed with sodium heparin, 8 ml, 16×100 mm, green, PET, pack.100 pcs.
Vacuum tube MiniMed with sodium heparin, 8 ml, 16×100 mm, green, PET, pack.100 pcs.
from 1 755 ₽
Test tubes are used to count blood cells and study plasma parameters. When mixed with the collected material, heparin blocks the activity of thrombin and inhibits the transition of soluble fibrinogen to insoluble fibrin, inactivating irreversible clotting factors. Material for research............... heparinized blood, plasma Scope of application............................ immunology, hematology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
from 150 000 ₽
1 supp.
The Europolitest company continues to release its "bestseller" cultivator KVM-05. This cultivator was developed and produced jointly with the Candidate of Biological Sciences prof. Grigoriev and LLC "Omikron", LLC "SFU-System" Krasnoyarsk. Since 2021, due to the reorganization of the production chain, the production of cultivators of the KVM series has been established by Europolitest LLC in the mode of a full production cycle. The thermophilic strain of chlorella algae has been widely used in ecocontrol laboratories, biotests with this test object are by far the most automated biotests that allow reducing time at all stages of work (building up the uterine culture, sample exposure in the biotest, registration of the test function). Cultivator KVM-05 is a long-lived among cultivators of this purpose and a standard of reliability, reproducibility and durability. Used in techniques: - Methodology for determining the toxicity index of nanopowders, products made of nanomaterials, nanopoints, waste and sewage sludge containing nanoparticles by changing the optical density of the Chlorella algae test culture (Chlorella vulgaris Beijer). FR.1.39.2010.09103; MVI 1/25-2010. - Methodology for determining the toxicity of samples of surface fresh, groundwater, drinking water, wastewater, water extracts from soil, sewage sludge and waste by changing the optical density of the chlorella algae culture (Chlorella vulgaris Beijer). MON F T 14.1:2:3:4.10-04 / 16.1:2.3:3.7-04 FR.1.31.2009.06642. - Methodology for determining the toxicity of drinking, natural and wastewater, water extracts from soils, sewage sludge and waste by changing the relative index of delayed fluorescence (OPF) cultures of chlorella algae (Chlorella vulgaris Beijer) HDPE F 14.1:2:4.16-09 / 16.1:2.3.3.14-09.
Evropolitest
Ivanteevka
Produced in: Moscow region
Muffle furnace LF-9/13-V1
Muffle furnace LF-9/13-V1
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; The door opens up and faces the user with the cold side; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x150x290 mm Overall dimensions, WxHxD, not more than 525x1015x620 mm Rated supply voltage, 220 V Rated power, W 5500
LOIP
Saint Petersburg
Produced in: Saint Petersburg