Search

3995 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 37
    By name of foreign product
    Loading...
  • 522
    Names
    Loading...
  • 3995
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3995 products
Combined mobile laboratory up to 35 kV (ETL-35K)
Combined mobile laboratory up to 35 kV (ETL-35K)
The combined laboratory up to 35 kV (ETL-35K) consists of: 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 100 kV. 2. Insulation parameters meter • – Transformation coefficient; • – No-load losses at low voltage; • – Short circuit resistance; • – Voltage and current; • – Power factor; • – Frequency of the measured voltage (current); • – Phase shift angle between voltage and current; • – Measurement of the active resistance of the windings. 3. Burning facility • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low-voltage cables); • – Built-in afterburning. 4. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 5. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 6. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where pipelines and cables intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method.
Produced in: Kolomna, Moscow region
VD-3.6×1.8
VD-3.6×1.8
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 3.6×1.8 Flange type according to GOST RV 51914-2002 Frequency range, GHz 53.57-78.33 VSWR 1.25 Losses, 2.5 dB Length, mm* 500
Produced in: Moscow
Contact thermometer TK-5.01PS
Contact thermometer TK-5.01PS
from 14 904 ₽
The digital contact thermometer TK-5.01PS is designed to measure the surface temperature of solids by direct contact of the probe with the measuring object. The digital contact thermometer consists of an electronic unit and a non-replaceable surface probe. Thermoelectric converters (TP) with NSH according to GOST R 8.585 are used as a thermosensitive element in the probe.
30 ml dark glass reagent bottle with a narrow neck and ground-in Primelab stopper
30 ml dark glass reagent bottle with a narrow neck and ground-in Primelab stopper
from 126 ₽
1 supp.
A 30 ml dark glass reagent bottle with a narrow neck and a ground-in stopper is a reliable means for storing and transporting reagents, the volume of which does not exceed 30 ml. The existing plug creates an absolute seal and protects the contents from external influences and evaporation leakage. Made from borosilicate glass 3.3. Characteristics: • Volume – 30 ml • Base diameter – 40 mm • Throat diameter – 18 mm • Height – 76 mm.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
SNVS Vacuum Furnace-3.3/12- I2
SNVS Vacuum Furnace-3.3/12- I2
High-temperature furnaces are capable of heating materials up to 1700 degrees. The scope of their application covers the heat treatment of various materials in an inert medium or vacuum. TULA-TERM furnaces are used for heat treatment of plastics, ceramics, metals, alloys, lacquers and other materials. The equipment allows sintering, annealing, soldering, quenching, drying, burning and molding. In industry, our installations are most often used for quenching parts and sintering hard alloys.
Produced in: Tula
2VVN1-12M(N) Water ring vacuum pump
2VVN1-12M(N) Water ring vacuum pump
The use of a 2VVN1-12M(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working parts of the 2VVN1-12M(N) pump. The 2VVN1-12M(N) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
Medical Electric Aquadistillator ADE-09
Medical Electric Aquadistillator ADE-09
from 22 900 ₽
Capacity: 1.0 l/h The quality of the produced water: FS.2.2.0020.18 " Purified water" Type of current, frequency, voltage: alternating single-phase, 50 Hz, 220 V Power consumption: 0.75 kW Overall dimensions (L×W×C), mm: 230x250x365 Weight: 3.9 kg Warranty period: 14 months from the date of sale
Livam
Belgorod
Produced in: Belgorod
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Appointment Athlete KAI-2.1001 • Determination of the type of damage and the distance to the place of damage to the cable. • Tracing a cable line up to 10 km. • Determination of cable depth up to 6 m. • Troubleshooting of cable lines by induction method. • Troubleshooting of cable lines by acoustic method. • Cable insulation testing.
Produced in: Kolomna, Moscow region
Vacuum tube MiniMed with sodium citrate 3.8%, 2.7 ml,13*75 mm, blue, glass, pack.100 pcs
Vacuum tube MiniMed with sodium citrate 3.8%, 2.7 ml,13*75 mm, blue, glass, pack.100 pcs
from 1 284 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
rhVEGF-A121
rhVEGF-A121
from 14 000 ₽
Vascular Endothelial Growth Factor is one of the key regulators of angiogenesis. The most important role in the human body is played by a protein of the VEGF family called VEGF-A. VEGF-A is a 45 kDa glycoprotein homodimer and plays a key role in chemotaxis and angioblast differentiation, endotheliocyte (EC) proliferation, vasculogenesis, and vascular remodeling. As a result of alternative splicing or proteolytic cleavage, 4 main isoforms of VEGF-A are formed, consisting of 121, 165, 189, or 206 amino acid residues.
Produced in: Moscow
Vacuum tube MiniMed with K2-EDTA and separation gel, 1ml, 13×75mm, purple, glass, pack.100 pcs.
Vacuum tube MiniMed with K2-EDTA and separation gel, 1ml, 13×75mm, purple, glass, pack.100 pcs.
from 1 592 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
PLS-04 Heating plate
PLS-04 Heating plate
Laboratory heating plate with two heating sections, with the possibility of setting the temperature and heating time, with a large heating surface area. The heating platforms are made of duralumin. The size of the total heating surface: 568x440 mm. Heating temperature of the plate surface: 40-400 oC.
Produced in: Tomsk