Search

3941 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Areas of use
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 41
    By name of foreign product
    Loading...
  • 550
    Item names
    Loading...
  • 3941
    Russian analogue
    Loading...
  • 24
    Areas of use
    Loading...
  • 132
    Manufacturer
    Loading...
View:
3941 products
Crystallization bowl diam.180 mm, pack.1 pc /box.24 pcs
Crystallization bowl diam.180 mm, pack.1 pc /box.24 pcs
from 1 211 ₽
Designed for evaporation and recrystallization of chemicals. Made of TS glass according to GOST 21400-75.TU 4320-012-29508133-2009.
MiniMed
Suponevo
Produced in: Bryansk region
Apparatus for dispersing petroleum products ARN-LAB-03
Apparatus for dispersing petroleum products ARN-LAB-03
A device for quality control of petroleum products Automatic apparatus for determining the maximum temperature of filterability on a cold filter with an integrated cooling system PTF-LAB-12 The automatic apparatus PTF-LAB-12 is designed to determine the maximum temperature of filterability on a cold filter in accordance with GOST 22254-92, GOST R 54269-2010, GOST EN 116-2013, ASTM D6371, IP309 and other similar standards in the temperature range from -67 ° C to room temperature. Developed taking into account all the requirements of state standards for testing. PTF-LAB-12 is equipped with an integrated cooling system of the bath, which allows you to reach the lower temperature limit of -67 ° C without using external cooling systems. Technical specifications: The volume of the analyzed sample is 45 ml Measurement range of filterability temperature from -67 °C to room temperature Accuracy of maintaining sample temperature ± 0.5 °C (at bath temperature -34 °C) ± 1.0 ° C (at bath temperature -51 °C) ± 2.0 °C (at bath temperature -67 °C) Creating a vacuum built-in diaphragm pump Maintaining the temperature of the cooling bath Integrated cooling system Step-by-step temperature control (-34 °C, -51 °C and -67 °C) Built-in memory of at least 1000 protocols Color LCD display with touch screen The device is controlled by touch Supply voltage 220 V Power consumption 300 W Overall dimensions, WxDxH 315x470x405 mm Weight 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
A set of BNTI devices-05-04- K
A set of BNTI devices-05-04- K
It is used for determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 20287 (method A), EN 23015, ASTM D97 and GOST 18995.5.
Produced in: Tomsk
LA-100 Nitrogen Vacuum Trap
LA-100 Nitrogen Vacuum Trap
The LA-100 nitrogen filler trap is installed on the inlet flange of the diffusion pump and is designed to reduce the flow of working fluid vapors into the pumped volume by condensing them on the elements of the freezing device cooled with liquid nitrogen.
Produced in: Kazan
Vacuum tube MiniMed with separation gel, 8 ml, 16×100 mm, red, PET, pack.100 pcs.
Vacuum tube MiniMed with separation gel, 8 ml, 16×100 mm, red, PET, pack.100 pcs.
from 1 650 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
FNCH-78
FNCH-78
Structurally, waveguide LPF 37-78 GHz are made on metal plates located in the center of the E-plane of the waveguide. These LFS can be used in conjunction with waveguide bandpass filters to increase the suppression of spurious signals and expand the upper band of the barrier. Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 3.6×1.8 Bandwidth Fh-Fb at the level of -1 dB, GHz 60-78 The barrier band at the level of -30 dB, GHz 85-120 Bandwidth loss, 0.5-1.2 dB
Produced in: Moscow
Chamber furnace with sliding hearth SNOT-10.10.10/12
Chamber furnace with sliding hearth SNOT-10.10.10/12
from 680 000 ₽
Designation: SNOT-10.10.10/12 Temperature: 1200 Door opening: Electromechanical Hearth drive: electromechanical Camera Size (WXDXH) 1000x1000x1000 Regulation zones: 1
Produced in: Tula
Oscilloscope S1-167/2
Oscilloscope S1-167/2
Designed for the study of periodic electrical signals by visual observation and measurement of their amplitude and time parameters on the scale of the CRT screen in the frequency band 0 - 25 MHz with a built-in multimeter measuring voltage and DC power, the average square value of voltage and AC power, DC electrical resistance. Technical specifications: Vertical deviation Number of channels 2 Bandwidth 0-25 MHz Deviation coefficients 2 mV/div-10 V/div (step 1-2-5) Installation error ± 3% Rise time of PH <= 14 nsec Input impedance 1 mOhm/23 pF, with divider 1:10-10 mOhm/12 pF with open input <=110 V with closed input <=110 V with divider 1:10 <= 250 V range U post. U AC: 1 mV–500 V Error 0.1% (U post); 0.3% -1% (U perem. 40 Hz–100 kHz) Range I post., I AC.: 1 mA–2 A Error: 0.25% (I post.); 0.5% (I perem. 40 Hz–5 kHz) R Range: 1 Ohm–1 mOhm Error R: 0.2% 3.5-digit indicator Automatic selection of limits.
MNIPI
Minsk
Produced in: Belarus, Minsk
VT3-2 Liquid thermostat
VT3-2 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external consumers of open or closed type. Pump for closed or open type thermostating systems. All-metal stamped tub with a volume of 3 liters and a depth of 150 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. Bath volume 3 l Overall dimensions 170x350x430 mm The open part of the bath is 75x35 mm Bath depth 150 mm Weight 11 kg Power consumption 2.2 kW
Produced in: Tomsk
CRYO basket-VT-06-K
CRYO basket-VT-06-K
It is designed to accommodate thermostatically controlled objects in the inner bath of the liquid low-temperature thermostat CRYO VT 06. The height-adjustable bottom allows objects to be immersed in the coolant to the required depth. Internal dimensions 300x200x120 mm Weight 2.7 kg
Produced in: Tomsk