Search

3964 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Areas of use
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 41
    By name of foreign product
    Loading...
  • 552
    Item names
    Loading...
  • 3964
    Russian analogue
    Loading...
  • 24
    Areas of use
    Loading...
  • 132
    Manufacturer
    Loading...
View:
3964 products
 Green DPSS Laser 522 nm KLM-522-x
Green DPSS Laser 522 nm KLM-522-x
DPSS lasers of the KLM-522/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
NANOEDUCATOR II
NANOEDUCATOR II
NanoEducator II, despite its compactness and ease of operation, supports all basic techniques of atomic force and scanning tunneling microscopy, so it can be used for any routine AFM and STM measurements and experiments in scientific research. Here are the results of some experiments in various scientific applications: Study of atomic structures Study of metallic nanostructures Study of magnetic structures Study of polymer objects Study of biological objects Study of carbon nanomaterials
Produced in: Moscow, Zelenograd
Liquid low-temperature thermostat CRYO-MT-07
Liquid low-temperature thermostat CRYO-MT-07
The operating temperature range is -60...+80 °C. Large bath with temperature stability ± 0.02 °C in the entire working volume. Bath volume 70 l Overall dimensions 630x940x1370 mm The open part of the bath 280 mm Bath depth 500 mm Weight 180 kg Power consumption 5.8 kW
Produced in: Tomsk
Heating element for a 1.3 kW 220 V distiller
Heating element for a 1.3 kW 220 V distiller
from 1 860 ₽
The tank for the 1.3 kW aquadistillator is made of stainless steel.
Livam
Belgorod
Produced in: Belgorod
Vacuum tube MiniMed with K3-EDTA, 3 ml, 13×75mm, purple, glass, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA, 3 ml, 13×75mm, purple, glass, pack.100 pcs
from 1 163 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Dividing funnel, tap with threaded seal
Dividing funnel, tap with threaded seal
from 590 ₽
It is used to separate immiscible liquids in extraction procedures. Kinds:VD-1-10 VD-1-25 VD-1-50
MiniMed
Suponevo
Produced in: Bryansk region
Sink LAB-M MO ME 120.75.90 PP
Sink LAB-M MO ME 120.75.90 PP
Furniture for laboratory work. Table-sink on a support pedestal made of metal LAB-M MO ME 120.75.90 PP Width: 1200 Depth: 750 Height: 900 Package contents: table top – a single module made of polypropylene Attention! It is not recommended to use
LOIP
Saint Petersburg
Produced in: Saint Petersburg
UNM-2000/6000 portable magnetizing device
UNM-2000/6000 portable magnetizing device
The principle of operation of the means of magnetic particle control The portable device UNM-2000/6000 of the MANUL series is a magnetic particle flaw detector that provides measurements by the applied field method and the residual magnetization method using direct, alternating and pulsed current with specified parameters. External magnetizing devices included in the kit (solenoids, electromagnets, contact devices for connecting cables) allow for longitudinal, transverse and circular magnetization of the object under study. A special magnetic powder, dry or in the form of an emulsion, is applied to the controlled surface. Inhomogeneities of the magnetic field in the places of defects lead to the accumulation of powder particles, thus "showing" a hidden picture. Design features and advantages of the UNM-2000/6000 powder flaw detector: In the MANUL series, the UNM-2000/6000 device is capable of providing the highest magnetization current (up to 6000 A in pulse mode), which allows you to control products having a large mass or size, as well as those made of magnetohard alloys; The device can be included in automated quality control stands: there are network interfaces (LAN, Bluetooth, Wi-Fi) for connection; microprocessor control provides storage and reproduction of magnetization and demagnetization parameters, logging of control results, automatic demagnetization; The design is modular, allows for changes to implement the individual wishes of the customer; It fully complies with the following standards: GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018 , RD 34.17.102-88, RD-13-05-2006 and other Russian and foreign standards regarding the requirements for magnetizing devices and magnetic particle flaw detectors; It is approved for use by industry regulatory documents, in particular, by the Russian Railways. Scope of application Magnetic powder control devices are widely used in various industries, construction and transport, from steel and pipe rolling plants to organizations engaged in the operation and repair of machines, mechanisms and vehicles. Magnetic powder flaw detectors belong to the means of non-destructive testing and therefore can be used to detect defects in products and structures operating under pressure, including at chemical and oil and gas industry enterprises, as well as during the operation of pipelines. In particular, devices for monitoring by the magnetic powder method have proven themselves well at Russian Railways and metro enterprises engaged in the operation and repair of rolling stock, including for the control of shafts, wheels and wheel pairs, gearboxes, springs, couplers and other loaded components and parts. Technical specifications: Magnetization currents: Variable, Pulse, Rectified (only for solenoid and electromagnet) The measurement error of the magnetization current is no more than 10%. Characteristics of the pulse current: The repetition frequency of unipolar current pulses during magnetization and of multipolar current pulses during demagnetization is (2 ± 0.2) Hz. The duration of the current pulses is at least 1.5 ms. Magnetic characteristics of the solenoid: The maximum alternating magnetic field in the center of a single solenoid is at least 100 A/cm. The maximum alternating magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 60 A/cm. The maximum permanent magnetic field in the center of a single solenoid is at least 80 A/cm. The maximum permanent magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 50 A/cm. Values of magnetization currents: The maximum alternating magnetization current in the unwound cable is 6 m × 50 mm2 and on the electrical contacts is at least 2000 A. The maximum pulse magnetization current in an unwound cable of 4 m × 10 mm2 and on electrical contacts is at least 6000 A. The current adjustment range in the solenoids and the electromagnet is from 0.5 to 4.5 A. Characteristics of the electromagnet: The maximum alternating magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 75 A/cm; - in the 40 mm gap: at least300 A/cm. The maximum constant magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 100 A/cm; - in the 40 mm gap: at least 400 A/cm. Operating mode: The operating mode is cyclic: magnetization/pause. The magnetization time is adjustable from 1 to 40 s. The demagnetization time is adjustable from 5 to 60 seconds. Demagnetization of parts is performed automatically. The time of setting the operating mode is no more than 15 seconds. The duration of continuous operation is at least 8 hours. Power supply parameters: The device is powered by an AC power supply with a voltage of 220 V and a frequency of 50 Hz. The power consumed from the network is no more than 5 kVA. Overall characteristics: Overall dimensions of the device (w × h × d) – no more than 267×245×465 mm. The weight of the device is not more than 50 kg. Other characteristics: The average worktime before failure is at least 12500 hours. The average recovery time is no more than 6 hours. The average service life of the device is at least 10 years. Сompliance with standards The device fully complies with the requirements of GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018, RD 34.17.102-88 and RD-13-05-2006 in terms of the requirements for magnetizing devices and magnetic particle flaw detectors. Identification of the load. It performs automatic identification of the types of connected load: cables, solenoids and electromagnet. Control of the connected load current It allows you to control the current of the connected AC/DC electromagnets and solenoids. The kit includes: 1 Electrical contact with cable, cross section 50 mm2, length 3m 2 Solenoid cable, 3m long 3 Solenoid cable, 0.5m long 4 Magnetizing cable, cross section 10 mm2, length 6m 5 Magnetizing cable, cross section 50 mm2, length 6m 6 Solenoid - 2pcs 7 The electromagnet is manual 8 Trolley 9 Power unit UNM 2000/6000
Produced in: Moscow
VT12-2 Liquid thermostat
VT12-2 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external consumers of a closed or open type. Pump for closed or open type thermostating systems. All-metal stamped tub with a volume of 12 liters and a depth of 150 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. Bath volume 12 l Overall dimensions 420x330x430 mm The open part of the bath is 150x260 mm Bath depth 150 mm Weight 14 kg Power consumption 2.2 kW
Produced in: Tomsk