Search

3995 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 37
    By name of foreign product
    Loading...
  • 522
    Names
    Loading...
  • 3995
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3995 products
Universal Metolab 703 Hardness Tester
Universal Metolab 703 Hardness Tester
Stationary universal METOLAB 703 hardness tester is a multifunctional device designed to measure the hardness of materials and products on the Rockwell, Brinell and Vickers scales. The device is a modification of the METOLAB 701 and METOLAB 702 meters. Among the features of the METOLAB 703 hardness tester, the following should be mentioned: a special force sensor for monitoring the applied load; a large and bright color display; software with many functions (including statistical ones – calculation of minimum/average/maximum values, conversion of the results into various scales, automatic switching on of the load, storing data in memory); U-disk for saving and transferring data; creating and editing spreadsheets in Excel format; digital calibration and much more. Distinctive features of the stationary universal multifunctional METOLAB 703 hardness tester: A large number of scales for measurements; Rockwell scales: A, B, C, D, E, F, G, H, K, L, M, P, R, S, V; Brinell scales: HBW1/5, HBW2.5/62.5, HBW1/10, HBW2.5/15.625, HBW1/30, HBW2.5/31.25, HBW2.5/62.5, HBW10/100, HBW5/125, HBW2.5/187.5; Vickers scales: HV5, HV10, HV20, HV30, HV50, HV100, HV12; Multifunctional software in the basic package; Fully Russian-language device menu, simple and intuitive interface; Wide range of measured values: 8 – 650 HB; 20 – 93HRA; 20 – 100 HRB; 20 – 70 HRC; 8 – 2900 H; Load application monitoring using a force sensor; Large and bright color display; Creating and editing spreadsheets in Excel format; U-disk for saving data; Digital calibration of the device; Built-in measuring microscope with backlight. Basic delivery package: Stationary universal METOLAB 703 hardness tester; Conical diamond Rockwell indenter (120° angle) - 1 pc.; Vickers diamond indenter (136° angle) - 1 pc.; Indenter with 1.5875 mm ball - 1 pc.; Indenter with 2.5 mm ball - 1 pc.; Indenter with 5.0 mm ball - 1 pc.; Indenter with 10.0 mm ball - 1 pc.; Large flat table 150 mm - 1 pc.; Medium flat table 60 mm - 1 pc.; V-shaped table 40 mm - 1 pc.; Hardness measures - 1 set; 15x microscope - 1 pc.; 2.5x lens - 1 pc.; 5.0x lens - 1 pc.; User Manual.
Metolab
Moscow
Produced in: Moscow
Circulation chiller A300
Circulation chiller A300
A small buffer bath with a volume of 4 liters. Feeding pump with magnetic coupling for external closed-type thermostating systems. Cooling capacity 300 W at +20 °C. Overall dimensions 275x440x350 mm Weight 26 kg Power consumption 1.2 kW
Produced in: Tomsk
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
1 supp.
Technical specifications: The upper limit of the measurement range is 5 mg/kg Analysis time 1-5 min Permissible sample weights are 10-500 mg The weight of the console is 17 kg Air pumping speed 1-3 l/min Dimensions and weight of the analyzer 470x210x110 mm; 7.5 kg Power supply of the PIRO-915+ 220 V, 700 W Analyzer power supply 220 V, 15 W Dimensions of the power supply and pumping unit no more than 400x280x135 mm The dimensions of the thermal camera unit and the remote optical unit are no more than 430x340x135 mm The upper limit of the measurement range for sample weighting is 20 mg 200 mg/kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Welder's kit
Welder's kit
from 31 581 ₽
It controls temperature, air environment and welding seam surface during welding operations. •
Produced in: Moscow
Vacuum tube MiniMed without filler, 7 ml, 13×100 mm, red, PET, pack.100 pcs,Minimed
Vacuum tube MiniMed without filler, 7 ml, 13×100 mm, red, PET, pack.100 pcs,Minimed
from 649 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
External VT-D temperature sensor
External VT-D temperature sensor
It is necessary for accurate temperature maintenance in external objects. The diameter and length of the submerged part are 3 and 240 mm, respectively. The nominal static characteristic of Pt1000.
Produced in: Tomsk
NGSH V1.3 x 0.65 low-temperature noise generator
NGSH V1.3 x 0.65 low-temperature noise generator
Designed for: use as the primary reference of the spectral power of the noise radio emission SPMSH in the frequency range 140-220 GHz; use as a source of noise signal in the mm wavelength range for use with radio equipment; measuring the noise coefficient of receivers, amplifiers, for tuning and adjusting electronic devices.
VNIIFTRI
Mendeleevo
Produced in: Mendeleevo, Moscow region