Crystallization bowl diam. 60 mm, pack.10/240 pcs
Crystallization bowl diam. 60 mm, pack.10/240 pcs
from 227 ₽
Designed for evaporation and recrystallization of chemicals. Made of TS glass according to GOST 21400-75.TU 4320-012-29508133-2009.
MiniMed
Suponevo
Produced in: Bryansk region
NV-1500 SHV-B-NERZH Fume cupboard with stainless steel countertop
NV-1500 SHV-B-NERZH Fume cupboard with stainless steel countertop
from 81 338 ₽
The Korsa NV-1500 SHV-NERZH Laboratory fume cupboards are single—frame cabinets with a width of 1410 mm with a stainless steel countertop. External dimensions of the cabinet (W×D×H): 1410×700×1960 mm. Dimensions of the working area (W×D×H): 1378×540×750 mm. Table top: stainless steel. Convenient fume cupboards for comfortable work in the laboratory Working surface material: stainless steel. It is well suited for biological or medical laboratories, but it is not recommended for use in chemical laboratories. It is resistant to prolonged exposure to temperature, organic solvents, and oils. It has limited resistance to short-term exposure to concentrated mineral acids and alkalis and is destroyed by prolonged exposure to concentrated acids. The working area is closed by a single lifting frame with a counterweight. It has two exhaust zones: the hood of the exhaust box and the level of the countertop. Diameter of the flange for connection to the ventilation system: 150 mm. Working area size (W×D×H): 1378×540×750 mm. Please note that the cabinet narrows upwards. At a height of 50 cm, the depth of the working area will be 410 mm, at a height of 70 cm: 365 mm. If you need to place high equipment, then make sure that it corresponds to the dimensions of the camera, otherwise you will not be able to close the cabinet. The height of the raised glass above the cabinet: 510 mm, that is, with the glass raised, the total height of the cabinet will be 2470 mm. The working area is illuminated by an LED lamp (included in the package). The switch is located on the right-hand side of the cabinet, next to the sockets. The fume cupboard is equipped with two sockets, one of them with grounding. Sockets have the IP20 degree of protection, maximum load: 1.5 kW. The base of the cabinet is an all-welded metal frame in powder coating. The side laminated panels (chipboard with a thickness of 16 mm) are edged with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. The cabinet legs are adjustable in height within two centimeters, allowing you to place the cabinet even on a rather uneven floor.
NV LAB
Moscow
Produced in: Moscow, Moscow region
ND-630 High-vacuum diffusion pump
ND-630 High-vacuum diffusion pump
The working condition of the ND-630 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (uner technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-630 diffusion pump is a maximum of 9 liters, a minimum of 6 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-630 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-630 diffusion pump up to 360°C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 600 l/h, for the oil reflector it is 80 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
Aquarius Deionizer
Aquarius Deionizer
from 96 000 ₽
It is intended for obtaining in laboratory conditions from distilled especially pure (deionized) water used for the preparation of solutions, chromatographic samples, refueling of electrolytic hydrogen/oxygen generators and other purposes. Technical specifications The specific conductivity of the resulting water is not more than 0.20* mkSxcm Capacity is at least 6* l/h Metal ion content is not more than: Fe, Pb, Ni, Co 5* mcG/l Zn, Cd, Cu, Mn 1*m cG/l The optical density of ammonia relative to bidistilled water is no more, D - 0.01* Operating time of the replaceable cassette (total volume of purified water) is not less than 700 liters. Volume of refilled distilled water is 1 l Overall dimensions are 180x420x430mm  The weight of the filled device is no more than 9 kg Operating conditions: ambient temperature from +10 ° C to +35 ° C Power supply from single-phase AC 220 V., 50 Hz The power consumption is not more than 20 VA.
Produced in: Moscow
DIGITAL VACUUM METERS
DIGITAL VACUUM METERS
A digital vacuum gauge is a device for measuring pressure in rarefied gases. The device is used for the study of chemical and physical processes in the steel, chemical industry, for setting up machine units. It is used to evaluate the performance of electronic lamps, when filtering various media. In this article we will consider the principle and features of the device, its purpose and the specifics of the choice. Technical specifications: To measure vacuum in medium and highly discharged environments, it is necessary to select sensitive equipment. The device must have the following characteristics: Wide range of measured pressure (from 10-3 torr); High sensitivity: up to 1 atm; Absence of rubbing mechanical parts; Support for different display units: torrs, pascals, mmHg Support for different display units: torrs, pascals, mmHg; Visual electronic display; Insignificant power consumption.
Produced in: Yoshkar-Ola, Mari El
NV-1200 SHV-U Fume cupboard with plumbing and countertop made of granite tiles
NV-1200 SHV-U Fume cupboard with plumbing and countertop made of granite tiles
from 48 282 ₽
The Kors NV-1200 SHV-U laboratory fume hood is a single—frame cabinet with a ceramic granite countertop 1100 mm wide and a small built-in polypropylene sink. External dimensions of the cabinet (W×D×H): 1100×700×1960 mm. Dimensions of the working area (W×D×H): 1068×540×750 mm. Table top: granite tiles. Reliable fume cupboard for laboratories The cabinet is available in two versions: with a hood from the lower cabinet and without it. In a cabinet with a hood, various aggressive reagents can be stored, in a cabinet without a hood, it is better to store only laboratory glass or instruments. Working surface material: porcelain tile. It is moisture-resistant and perfectly withstands high temperatures. It is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. Limited resistance to hydrofluoric acid. This is one of the most popular types of countertops for laboratory furniture. The small sink-drain is made of polypropylene, resistant to aggressive chemicals. Its diameter is 135 mm and its depth is 110 mm. The base of the cabinet is made on an all-welded metal frame in powder coating. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a durable PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The cabinet legs are adjustable in height within two centimeters, allowing you to place the cabinet even on a fairly uneven floor. Working area of the fume cupboard The working area is closed by one lifting frame with a counterweight. It has two exhaust zones: the hood of the exhaust box and the level of the countertop. Diameter of the flange for connection to the ventilation system: 150 mm. Working area size (W×D×H): 1068×540×750 mm. Please note that the cabinet narrows upwards. At a height of 50 cm, the depth of the working area will be 410 mm, at a height of 70 cm: 365 mm. If you need to place high equipment, then make sure that it is small enough in length, otherwise you will not be able to close the cabinet. The working area is illuminated by a fluorescent lamp (included in the package). The switch is located on the right side of the cabinet, next to the sockets. The fume cupboard is equipped with two sockets, one of them with grounding. Sockets have the IP20 degree of protection, maximum load: 1.5 kW. What are the other options? If you need to place large equipment, you may be interested in the cabinets for muffle furnaces. Also in the line there are large cabinets with plumbing fixtures: NV-1500 NV-U and two-frame NV-1500 SHV-U and NV-1800 SHV-U.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Metal double support cabinet with 1 door and 3 drawers LAB-PRO VOLUME 3 116.50.86
Metal double support cabinet with 1 door and 3 drawers LAB-PRO VOLUME 3 116.50.86
Metal double support cabinet with 1 door and 3 drawers Length, mm: 1160 Depth, mm: 500 Height, mm: 860 The case is metal painted with powder paint (RAL 7035) with the texture of shagreen leather Completely made of steel painted with powder paint (RAL 7035) with the texture of shagreen leather Frameless housing design Two compartments: left - with 3 drawers, right - with a swing door The side walls, partition and facades are double. The thickness of the side walls is 19 mm, the facades are 18 mm The facades are filled with noise-absorbing material Handles - polypropylene Right compartment – Hinges with an opening angle of 270o – Lock – Easily removable shelf with the possibility of installation at 3 different height levels. The shelf has a lock – The permissible load on the shelf is 30 kg Left compartment (with 3 drawers) – Lock in the upper drawer – Telescopic guides of full extension – Internal size of the drawer: upper and middle drawers 500*410*85 mm, lower – 500*410*295 mm – Permissible load per box – 30 kg Hidden adjustable supports (0 - 40 mm). The adjustment of the supports is carried out from inside the pedestal through the base of 8 standard versions of the working surfaces of LAB-PRO RP
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Shaft furnace industrial SSHO-10.20/11
Shaft furnace industrial SSHO-10.20/11
Designation SSO-10.20/11 Power, kW 90 Diameter, mm 1000 Height, mm 2000
Produced in: Tula
Analytical scales VLA-220S-O
Analytical scales VLA-220S-O
from 359 990 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the verification division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals:from 0.01g to 50g incl. ±0.5; sv. 50g to 200g incl. ±1.0; sv. 200g to 220g incl. ±1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 The alignment weight is built 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Programmable magnetic stirrer with heating PL-HR-steps. Primelab
Programmable magnetic stirrer with heating PL-HR-steps. Primelab
from 55 000 ₽
1 supp.
Primelab sand sauna, not included in delivery. Supplied separately. High-tech and productive magnetic stirrer with heating PL-HR-Steps, 20 liters, designed for laboratories of various profiles, including research and production purposes. The stirrer can mix at speeds up to 1500 rpm and heat up to +550 °C. The working platform is made of stainless steel, and the top covering is made of chemically resistant refractory glass (glass ceramics). The heated magnetic stirrer PL-HR-Steps has expanded functionality compared to the Basic modification. The Steps modification allows users to create and run their own special programs based on a graph of temperature and rotation speed versus time. The user can create a program by specifying a set of parameters for each step, including step duration, set temperature and rotation speed. The program subsystem provides flexible control of the heating and mixing process. The main functionality of the subsystem includes: • number of program steps from 1 to 5; • maximum step duration up to 990 minutes; • possibility of manual control control during program execution; • ability to run 1 program (heating/rotation). The PL-HR-Steps stirrer does not support "Gentle heating" modes. The user selects temperature, speed and time settings using two round knobs. The digital display shows the set and actual characteristics, as well as icons of the processes and functions being performed. The set parameters are saved in non-volatile memory. After heating is turned off, a warning about a hot platform is displayed on the screen. There is protection against overheating: at +550 °C the electric heating element automatically turns off. The stirrer is compatible with the PT1000 temperature sensor. The device is equipped with an armature failure monitoring function: if the rotation stops, the electric motor restarts. Main characteristics: • Orange color • Protection class (according to DIN EN60529): IP21 • Working surface of the platform: fireproof glass (glass ceramics) • Number of mixing places: 1 • Maximum volume of mixed liquid: 20 l • Motor power: 16 W • Range of operating speeds of the motor shaft: 50-1500 rpm • Discreteness of setting the specified rotation speed: 10 rpm • Maximum platform heating temperature: 550 °C • Resolution of setting the set temperature: 1 °C • Temperature maintenance accuracy: 1% • Power consumption: 1020 W • Overall dimensions LxWxH: 350x220x120 mm • Platform working surface size LxW: 200x200 mm • Device weight: 4.4 kg Primelab sand sauna, not included in delivery. Supplied separately.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Mobile laboratory for 0.4-35 kV cable lines (ETL-35)
Mobile laboratory for 0.4-35 kV cable lines (ETL-35)
Laboratory equipment for 0.4-35 kV cable lines (ETL-35) 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 100 kV. 2. Burning facility • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low-voltage cables); • – Built-in afterburning. 3. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 4. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 5. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where the pipeline and cable intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method.
Produced in: Kolomna, Moscow region
Cupboard for dishes LAB-M SHP 50.50.194
Cupboard for dishes LAB-M SHP 50.50.194
Furniture for laboratory work. Cupboard for dishes Length, mm: 500 Depth, mm: 500 Height, mm: 1940 PACKAGE CONTENTS housing – white melamine with a thickness of 16 mm, ABS edge of dark gray color facades – tinted light gray glass 2 compartments (the upper one is 686 mm high, the lower one is 1076 mm high) 5 shelves (1 built-in, 4 removable (1 in the upper compartment, 3 in the lower) with the possibility of rearrangement at 3 levels in height each).
LOIP
Saint Petersburg
Produced in: Saint Petersburg