Search

3996 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 21
    Foreign brand
    Loading...
  • 36
    By name of foreign product
    Loading...
  • 523
    Names
    Loading...
  • 3996
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3996 products
Laboratory drying cabinets SHS-40/5,0
Laboratory drying cabinets SHS-40/5,0
The electric drying cabinet SHS-40/5.0 is designed for drying, heating various materials in air environment at a maximum temperature of 500 ° C. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. Operating temperature- 500 ⁰C Power consumption - 2500 W Dimensions of the working chamber WxDxH- 390x360x39 mm Dimensions WxDxH- 600x640x59 mm Weight - 67 kg
MIUS
Tula
Produced in: Tula
Automatic installation of LK-100 for Kjeldahl decomposition (Thermoset reactor)
Automatic installation of LK-100 for Kjeldahl decomposition (Thermoset reactor)
1 supp.
Technical specifications: Maximum heating power, W 1500 Working volume of reaction tubes, 250 ml Number of reaction tubes 6 Power consumption from the mains 220 V, W 1550 Overall dimensions, mm 480x526x750 Weight, kg 25
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Flowmeter-counter ultrasonic Oriole
Flowmeter-counter ultrasonic Oriole
from 200 000 ₽
The ultrasonic Oriole flow meter is designed to measure the volumetric flow rate and volume of liquid in pressure pipelines. The measured medium can be any homogeneous isotropic liquid of various densities, including: clean cold and hot water supply and heating systems (up to +160 °C); natural water is clean and of a low degree of pollution; wastewater of low and medium degree of contamination; chemical solutions of acids, alkalis and other chemically aggressive media; mineral, synthetic and semi-synthetic machine oils; food products (vegetable oil, juices, syrups, vodka, ketchups, dairy products, etc.). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Mortise, contactless overhead outside and full-bore primary converters embedded in the process allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
Primelab Richter absorber (high-speed and small)
Primelab Richter absorber (high-speed and small)
from 1 810 ₽
Primelab is a company that produces and sells laboratory glassware of its own production. Accepts orders and carries them out in strict accordance with the customer’s technical specifications. The Richter Absorber Primelab is available in high-speed and small subtypes. Both are designed to purify liquids, gases and other impurities. The first is suitable for working with large volumes of gases or quick cleaning, and the second is for small volumes. They have an identical shape in the form of an elongated vessel with two spherical extensions at the top and two tubes. The Richter absorber was manufactured by Primelab from Czech borosilicate glass Simax, which is known for its strength and wear resistance. Suitable for use in various laboratories and small industries.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Sensor holder LTA-4DSH14
Sensor holder LTA-4DSH14
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
Produced in: Tomsk
Installation for measuring the volumetric activity of radioactive aerosols UDA-1AB
Installation for measuring the volumetric activity of radioactive aerosols UDA-1AB
Installation for continuous automatic monitoring of the concentration of radioactive aerosols in autonomous mode or as part of automatic radiation monitoring systems in the air of working rooms and ventilation systems. Purpose: measurement of the volumetric activity of alpha-emitting radionuclides and beta-emitting radionuclides contained in the form of aerosols in the air.
Doza
Zelenograd
Produced in: Moscow
Induction vacuum electric furnace IVP-17—17- In
Induction vacuum electric furnace IVP-17—17- In
The furnace provides a bottom drain, a device for mixing, the possibility of directional crystallization
VakETO
Mosrentgen
Produced in: Moscow
Set of devices GOST 11851 method A
Set of devices GOST 11851 method A
It is intended for placement in the BF bath and is used in determining the mass fraction of paraffins in oil in accordance with the method A of the State Standard 11851.
Produced in: Tomsk
Liquid thermostat THERMOTEST-05-1
Liquid thermostat THERMOTEST-05-1
Operating temperature range -80...+30 °C. Stability and uniformity of temperature in the working bath is not worse than ± 0.02 °C Bath volume 15 l Overall dimensions 510x800x1230 mm The open part of the bath is 90 mm Bath depth 430 mm Weight 115 kg Power consumption 4.2 kW
Produced in: Tomsk
Generator of pure nitrogen and zero air GCHA-18D-60V
Generator of pure nitrogen and zero air GCHA-18D-60V
from 330 000 ₽
It is intended for obtaining nitrogen of the highest purity and zero air in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than 99,999 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than, 0.0005 % vol. (5 ppm) Volume fraction of water vapor in nitrogen is not more than 0.0007 % vol. (7 ppm) The volume fraction of hydrogen in nitrogen is not detected Volume fraction of the sum of carbon-containing compounds in nitrogen in terms of methane is not more than 0.00001 % vol.(0.1 ppm) Maximum nitrogen capacity is not less than 18 liters/hour (300 ml/min) Nominal output pressure of nitrogen is 4 ati Volume fraction of water vapor in the generated air is not more than 0.0007 % vol. (7 ppm) The volume fraction of the amount of hydrocarbons in the produced air in terms of methane is not more than 0.00001 % vol. (0.1 ppm), (with a concentration of methane in the supply air not more than 5 ppm) Maximum air capacity is not less than 60 liters/hour (1000 ml/min) Nominal output air pressure is not less than 3.5 ati The time of setting the operating mode for single-shift work is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is not less than 5.5 ati Compressed air consumption, at nominal inlet pressure is no more than 480 l/h (8 l/min) Power consumption is not more than 150 VA Overall dimensions, (width x depth x height) are not more than 230x425x510 mm Weight is not more than 25 kg Operating conditions: ambient temperature, ° C, from +10 to +35 electric power supply from a single-phase AC network with voltage, V, 220 ± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator meets the electrical safety requirements of class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
NV-1800 Lv High laboratory tables (1800×700×850)
NV-1800 Lv High laboratory tables (1800×700×850)
from 57 580 ₽
NV-1800 LKv is a high laboratory table on a metal frame. The width of the table top (1800 mm) is the largest in the line of NV high tables. It is designed for standing work (table height: 850 mm). The NV-1800 LKv table has a metal frame painted with durable powder paint. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table when assembled (W×D ×H): 1800×700×850 mm. Working surface for your classes We offer laboratory tables with different working surface material: Version: Table top NV-1800 LLv: Laminate. An inexpensive solution suitable for school chemistry and physics classrooms, office work, placement of devices. NV-1800 LKv: Porcelain tile. A practical solution for most chemical, biological, medical laboratories and workshops. You can put drying cabinets, baths and other heating devices on it. NV-1800 LSPv: Chemically resistant plastic. A good choice for training workshops, analytical and medical laboratories. It does not tolerate high temperatures well, heating devices should not be placed on the surface. NV-1800 LNv: Stainless steel. Stainless steel is well suited for biological or medical laboratories, but it is not recommended for use in chemical laboratories. It has limited resistance to short-term exposure to concentrated mineral acids and alkalis and is destroyed by prolonged exposure to concentrated acids. NV-1800 LPv: Polypropylene. A specialized solution for chemical laboratories working with inorganic solvents. Advantages of NV-1800 Lv tables It is the largest table in the series, it is possible to organize there two full-fledged workplaces; A budget solution for laboratories that value the reliability and durability of furniture; You can choose a table top for your tasks; It is convenient to work while standing: the height of the working surface is 85 cm. Application of NV-1800 Lv tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Rubidium frequency and time standards H1-1011/1
Rubidium frequency and time standards H1-1011/1
The modular construction principle makes it easy to adapt the devices to the specific requirements of the consumer. The standards are available in four versions – H1-1011, H1-1011/1, H1-1011/2 and H1-1011/3, which differ in metrological characteristics and a set of installed devices (modules). The built-in diagnostic system allows you to quickly determine the operability and condition of the main devices of the standards. On the front panel of the devices H1-1011 and H1-1011/2 there is an LCD display and a control panel, with which you can quickly receive information about the current parameters of the devices included in the devices and adjust the frequency of the output signals. The H1-1011 and H1-1011/2 standards can receive chronometric information from GLONASS and GPS satellite radio navigation systems and use it to synchronize the local time scale and automatically adjust the actual frequency value of the built-in highly stable rubidium frequency standard. The H1-1011 and H1-1011/2 standards include: rubidium frequency standard H1-1014; MPR-01 satellite radio navigation systems receiver module; amplifier module for highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request). The scope of delivery (at the request of the customer) includes an antenna for the SRNS receiver as part of: antenna unit; mounting device; antenna cable (maximum length 60 m). The H1-1011/1 and H1-1011/3 standards include: the rubidium frequency standard H1-1013; two modules of amplifiers of highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request).
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod