Search

3996 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 21
    Foreign brand
    Loading...
  • 36
    By name of foreign product
    Loading...
  • 523
    Names
    Loading...
  • 3996
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3996 products
Round bottom tube with screw cap PrimeLab, 15 ml, 16x150
Round bottom tube with screw cap PrimeLab, 15 ml, 16x150
from 16 ₽
The round-bottom test tube with a screw cap PrimeLab has a wide range of applications in laboratories, scientific enterprises and various industries. This includes storage of liquid, bulk or gaseous substances, transportation, research, etc. The screw-closure lid creates a complete seal. Protects contents from external influences and leakage. Test tube characteristics: • Volume - 15 ml • Diameter - 16 mm • Length - 150 mm.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Measuring step attenuator D1-29
Measuring step attenuator D1-29
The device replaces the devices for checking the attenuators D1-13A and D1-25. D1-29 is a step attenuator with a range of attenuation from 0 to 110 dB with a step of 10 dB, operating in the frequency range from 0 to 150 MHz. The device consists of a housing with damping cells and a switch with a counting device. The housing contains coaxial input and output connectors, as well as additional connectors "40 dB" and "80 dB", necessary for the verification of the device. Technical specifications Operating frequency range 0 – 150 MHz Difference attenuation setting range (after 10 dB) 0 – 110 dB Input electrical resistance to direct current 50 ± 0.1 ohms The output electrical resistance to direct current when connected to the load input is 50 ± 0.1 ohms 25 ± 0.1 ohms The main absolute error of the difference attenuation setting relative to the 0 dB mark at direct current ± (0.002 - 0.02) dB The main absolute error of the difference attenuation setting relative to the 10 dB mark in the frequency range up to 30 MHz ± (0.004 - 0.9) dB The main absolute error of the difference attenuation setting relative to the 10 dB mark in the frequency range over 30 to 150 MHz ± (0.09 - 3.0) dB The maximum permissible value of the electrical voltage (DC or AC) at the input of the attenuator 3 In the operating temperature range from 5 to 40 ° C Overall dimensions, mm 149x95x149 Weight, not more than 3 kg
Produced in: Moscow
Vacuum tube MiniMed with K3-EDTA and separation gel, 8 ml, 16×100mm, purple, PET, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA and separation gel, 8 ml, 16×100mm, purple, PET, pack.100 pcs
from 1 056 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Chassis for MCRC19-14PS2 Media Converters
Chassis for MCRC19-14PS2 Media Converters
from 12 345 ₽
Using the chassis to install converters is an excellent solution for the efficient organization of signal conversion of various standards. For systems mounted in a basic 19" rack, we offer unmanaged chassis of standard size 2U for 14 unmanaged media converters (10/100 Mbit/s) with a slot for integrated power supplies. They support the possibility to install up to 14 converters.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
DC power supply B5-79/1
DC power supply B5-79/1
The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET Technical specifications Output voltage setting range from 0 to 60 V Output current setting range from 0.2 to 10 A Electrical output power, not less than 300 W The main error of the output voltage setting is ± 100 mV The main error of the output current setting is ± 100 mA Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 1 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 5 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 2 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 5 mA) Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mV Instability of the output current for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mA Operating temperature range from 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 240x128x313 Weight, not more than 6.0 kg
Produced in: Moscow
Laboratory LAB table-1800 LLn
Laboratory LAB table-1800 LLn
equipment side decorative panels – melamine 16mm thick all-welded frame made of rectangular metal profile painted with white powder paint adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-124a
Circulation thermostat LT-124a
The LOIP LT-124a modification device consists of an immersion thermostat-circulator LOIP LT-100 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current +10 ... +100 with tap water cooling °C Tvods+5 ...+100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, 0.17 bar Bath volume, l 24 The working fluid is water, water-glycerin mixture. The open part of the bath / depth, mm 360x296/200 Overall dimensions, mm 535x335x420 Weight, kg 14.2
LOIP
Saint Petersburg
Produced in: Saint Petersburg
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
Transmission of units of absorbed dose, directed, individual dose equivalents and their beta radiation power as part of the working standard of absorbed dose (PD) and absorbed dose power (MPD) of beta radiation in a tissue equivalent substance. ▪ Use of closed radionuclide beta radiation sources 90Sr+90Y (BIS-50, 22 GBk), 85Kr (KAC.D3, 15 GBk) and 147Pm (BIP-50, 10 GBk) ▪ Formation of a reference field from sources by a mobile emitter unit using smoothing filters ▪ Source holders with shutter and protective screens ▪ Calibrated length rods and laser device for centering and digitizing ▪ A video surveillance system of readings ▪ The possibility of using an automated extrapolation chamber as part of the installation to reproduce the absorbed dose (absorbed dose rate) of beta radiation in the tissue ▪ Measurement of ionization currents from 1 fA when using an extrapolation chamber and a precision electrometer ▪ Software for installation operation, calibration and calculations ▪ An alarm and blocking system, control of photon radiation levels in the measurement room and operator room
Produced in: Belarus, Minsk
Universal calibrator H4-201
Universal calibrator H4-201
Technical specifications: reproduction of DC voltage from 50 mv to 1000 V - ranges of 200 mV; 2; 20; 200; 1000 V - error 0.01 – 0.023 % reproduction of the sinusoidal AC voltage from 0.3 mV to 750 V - ranges of 200 mV; 2; 20; 200; 750 V - error 0.15 – 0.225 % - frequency range 20 Hz - 100 kHz (20 Hz - 5 kHz on the range. 200 V; 20 Hz - 2.5 kHz on the range. 750 V) reproduction of DC power from 0.03 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.012 – 0.022 % reproduction of AC power of sinusoidal shape from 3 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.062 – 0.23 % - frequency range 20 - 5000 Hz (45 - 1000 Hz on the range. 50 A) RS-232C interfaces; USB operating temperature range from + 5 to +40oC dimensions 184.5x465x540.5 mm weight 20 kg power supply ~ 230 V
MNIPI
Minsk
Produced in: Belarus, Minsk
Dosimetric thermoluminescent complex "DOSE-TLD"
Dosimetric thermoluminescent complex "DOSE-TLD"
Purpose: measurement of the individual dose equivalent of Hp(10) photon radiation; measurement of the individual dose equivalent of Hp(10) neutron radiation; measurement of the individual dose equivalent in the skin Hp(0.07) and the lens of the eye Hp(3) of photon and beta radiation; measurement of ambient dose equivalent H*(10) of photon radiation.
Doza
Zelenograd
Produced in: Moscow
Thermoelectric converter THA.GPKSH.013
Thermoelectric converter THA.GPKSH.013
The thermoelectric converter THA.GPKSH.013 is designed for measuring the temperature of gaseous and liquid chemical environments that do not destroy the protective shell. It measures the temperature in the clean air atmosphere, gaseous chemically non-aggressive environments with humidity up to 95 %
Termokon
Korolev
Produced in: Moscow region, Korolev