Search

3995 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 37
    By name of foreign product
    Loading...
  • 522
    Names
    Loading...
  • 3995
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3995 products
Sliding cabinet LAB-400 TNYA-3
Sliding cabinet LAB-400 TNYA-3
Furniture for laboratory work. Sliding cabinet Length, mm: 400 Depth, mm: 580 Height, mm: 680 PACKAGE CONTENTS case – melamine 16mm thick inner size of the box – 310*470* 120mm roller supports h=60mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
UNM-2000/6000 portable magnetizing device
UNM-2000/6000 portable magnetizing device
The principle of operation of the means of magnetic particle control The portable device UNM-2000/6000 of the MANUL series is a magnetic particle flaw detector that provides measurements by the applied field method and the residual magnetization method using direct, alternating and pulsed current with specified parameters. External magnetizing devices included in the kit (solenoids, electromagnets, contact devices for connecting cables) allow for longitudinal, transverse and circular magnetization of the object under study. A special magnetic powder, dry or in the form of an emulsion, is applied to the controlled surface. Inhomogeneities of the magnetic field in the places of defects lead to the accumulation of powder particles, thus "showing" a hidden picture. Design features and advantages of the UNM-2000/6000 powder flaw detector: In the MANUL series, the UNM-2000/6000 device is capable of providing the highest magnetization current (up to 6000 A in pulse mode), which allows you to control products having a large mass or size, as well as those made of magnetohard alloys; The device can be included in automated quality control stands: there are network interfaces (LAN, Bluetooth, Wi-Fi) for connection; microprocessor control provides storage and reproduction of magnetization and demagnetization parameters, logging of control results, automatic demagnetization; The design is modular, allows for changes to implement the individual wishes of the customer; It fully complies with the following standards: GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018 , RD 34.17.102-88, RD-13-05-2006 and other Russian and foreign standards regarding the requirements for magnetizing devices and magnetic particle flaw detectors; It is approved for use by industry regulatory documents, in particular, by the Russian Railways. Scope of application Magnetic powder control devices are widely used in various industries, construction and transport, from steel and pipe rolling plants to organizations engaged in the operation and repair of machines, mechanisms and vehicles. Magnetic powder flaw detectors belong to the means of non-destructive testing and therefore can be used to detect defects in products and structures operating under pressure, including at chemical and oil and gas industry enterprises, as well as during the operation of pipelines. In particular, devices for monitoring by the magnetic powder method have proven themselves well at Russian Railways and metro enterprises engaged in the operation and repair of rolling stock, including for the control of shafts, wheels and wheel pairs, gearboxes, springs, couplers and other loaded components and parts. Technical specifications: Magnetization currents: Variable, Pulse, Rectified (only for solenoid and electromagnet) The measurement error of the magnetization current is no more than 10%. Characteristics of the pulse current: The repetition frequency of unipolar current pulses during magnetization and of multipolar current pulses during demagnetization is (2 ± 0.2) Hz. The duration of the current pulses is at least 1.5 ms. Magnetic characteristics of the solenoid: The maximum alternating magnetic field in the center of a single solenoid is at least 100 A/cm. The maximum alternating magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 60 A/cm. The maximum permanent magnetic field in the center of a single solenoid is at least 80 A/cm. The maximum permanent magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 50 A/cm. Values of magnetization currents: The maximum alternating magnetization current in the unwound cable is 6 m × 50 mm2 and on the electrical contacts is at least 2000 A. The maximum pulse magnetization current in an unwound cable of 4 m × 10 mm2 and on electrical contacts is at least 6000 A. The current adjustment range in the solenoids and the electromagnet is from 0.5 to 4.5 A. Characteristics of the electromagnet: The maximum alternating magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 75 A/cm; - in the 40 mm gap: at least300 A/cm. The maximum constant magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 100 A/cm; - in the 40 mm gap: at least 400 A/cm. Operating mode: The operating mode is cyclic: magnetization/pause. The magnetization time is adjustable from 1 to 40 s. The demagnetization time is adjustable from 5 to 60 seconds. Demagnetization of parts is performed automatically. The time of setting the operating mode is no more than 15 seconds. The duration of continuous operation is at least 8 hours. Power supply parameters: The device is powered by an AC power supply with a voltage of 220 V and a frequency of 50 Hz. The power consumed from the network is no more than 5 kVA. Overall characteristics: Overall dimensions of the device (w × h × d) – no more than 267×245×465 mm. The weight of the device is not more than 50 kg. Other characteristics: The average worktime before failure is at least 12500 hours. The average recovery time is no more than 6 hours. The average service life of the device is at least 10 years. Сompliance with standards The device fully complies with the requirements of GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018, RD 34.17.102-88 and RD-13-05-2006 in terms of the requirements for magnetizing devices and magnetic particle flaw detectors. Identification of the load. It performs automatic identification of the types of connected load: cables, solenoids and electromagnet. Control of the connected load current It allows you to control the current of the connected AC/DC electromagnets and solenoids. The kit includes: 1 Electrical contact with cable, cross section 50 mm2, length 3m 2 Solenoid cable, 3m long 3 Solenoid cable, 0.5m long 4 Magnetizing cable, cross section 10 mm2, length 6m 5 Magnetizing cable, cross section 50 mm2, length 6m 6 Solenoid - 2pcs 7 The electromagnet is manual 8 Trolley 9 Power unit UNM 2000/6000
Produced in: Moscow
Laboratory work table low LAB-PRO SLn 120.65.75 KG
Laboratory work table low LAB-PRO SLn 120.65.75 KG
Laboratory work desk Table top: KG (porcelain stoneware) Length, mm: 1200 Depth, mm: 650 Height, mm: 750 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Serological pipette 50 ml.,sterile,ind.pack.,pack.25 pcs./box.100 pcs.,p/s,
Serological pipette 50 ml.,sterile,ind.pack.,pack.25 pcs./box.100 pcs.,p/s,
from 1 750 ₽
The pipettes are serological, disposable, made of crystalline polystyrene. Sterilized by gamma radiation. The color marking encodes the corresponding denomination according to international standards. Pipettes are apyrogenic, do not have hemolytic and cytoxic effects. The calibration on the pipettes is applied with black, abrasion-resistant paint. Pipettes of all denominations have a negative overflow scale, continuing the main scale.
MiniMed
Suponevo
Produced in: Bryansk region
PRIZ - a reflection prefix with the lower position of the sample and visualization of the object under study on the monitor
PRIZ - a reflection prefix with the lower position of the sample and visualization of the object under study on the monitor
The main advantage of the PRIZ prefix is the possibility of obtaining well–defined spectra of micro-objects after giving them the shape of a thin layer on mirror-polished metal plates (in the mode of the so-called double passage, when radiation twice penetrates through the layer of matter, reflecting from the mirror-substrate). The presence of a visual control system with a built-in video camera significantly increases the information content when setting up and the reliability of the results obtained. With the help of the prefix, it is also possible to register the reflection spectra of bulk samples and solid objects of arbitrary geometry in native form, including pharmaceuticals in the form of tablets, powders and granules, polymer fragments, LCP, films deposited on the surface. Technical specifications Transmission in the operating range of the spectrum, % of the input signal at least 40 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 Minimum initial dimensions of a solid sample, mm 0.2 × 0.2 The maximum area of the solid sample, mm 20X20X10 Variable focus range, mm 10 The diameter of the focus spot, mm 3 The angle of incidence of radiation (central beam) on the sample in the ZDO 45o mode Micro lens magnification / total magnification of the 4X visual channel Field of view of the optical system, mm 2 X 2.5 The resolution of the digital video camera is 640x480 Overall dimensions, mm 140×105×160 Weight, kg 1.16
SIMEKS
Novosibirsk
Produced in: Novosibirsk
A set of measures of electrical resistance H2-2
A set of measures of electrical resistance H2-2
Designed for storing and transmitting the size of a resistance unit, as well as for checking and calibration of working resistance measures and complex resistance meters with a four-pair or five-clamp connection scheme in the frequency range from DC to 10 MHz. Description: Each of the resistance measures H2-2 is a precision resistor, in series and in parallel to which fitting resistors are connected, placed in an aluminum housing. The measures have a four-pole connection scheme. Four BNC type connectors (plugs) are located on the wall of the housing. The distance between the connectors is 22 mm. In measures of 100 kOhm and 1 mOhm, it is possible to adjust the value of the time constant of the measure using a tuning capacitor.
MNIPI
Minsk
Produced in: Belarus, Minsk
Wireless set for measuring the temperature of ferrous metal melts with logging function
Wireless set for measuring the temperature of ferrous metal melts with logging function
from 95 600 ₽
The kit is designed to measure the temperature of ferrous metal melts. It consists of a digital contact thermometer TK-5.27 complete with a submersible high-temperature probe, designed to measure the temperature of metal melts in the range of +600 ° C ... +1800 ° C. The digital contact thermometer TK-5.27 is equipped with the function of recording measurements in the device's memory, followed by transferring data to a computer and providing reports in the form of tables and graphs. To measure the temperatures of metal melts, disposable thermocouples of the PPR (B) type with a protective tube length of no more than 900 mm are used. The kit is adapted to the replacement blocks of EVRAZTEMP ET-V-09-00. •
Produced in: Moscow
AC voltage voltmeter VK3-78A
AC voltage voltmeter VK3-78A
The voltmeter is capable of working both independently and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 (CPC). Technical specifications Measuring ranges of electrical quantities: - constant electrical voltage from 3 MV to 1000 V - SCR of alternating electric voltage in the frequency range from 10 Hz to 1 MHz (AC) from 10 MV to 1000 V - RF RF AC voltage in the frequency range from 10 Hz to 2000 MHz (RF) from 10 mV to 100 V - frequency of the measured AC voltage from 10 Hz to 1 MHz Measurement errors of electrical quantities: - constant electrical voltage ± (0.0021 - 17)% - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) ± (0.017 - 21)% - RF RF AC voltage in the frequency range from 10 Hz to 2000 MHz (RF) ± (0.21 - 16)% - frequency of the measured alternating electric voltage ± (0.1 -10.1)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 50 VA Overall dimensions, mm 489x91x381 Weight, not more than 8.5 kg
Produced in: Moscow
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Anemometer ASO-3
Anemometer ASO-3
from 67 630 ₽
Application range: 0.3 – 5.0 m/s; Accuracy characteristics: PG±(0.1+0.05V)m/s; Service life: at least 6 years; Overall dimensions: 110 x 110 x 105 mm; Weight – 0.45 kg; Application conditions: from -45°C to +50°C.
EMPGGO
Saint Petersburg
Produced in: Saint Petersburg