Search

3998 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 23
    Foreign brand
    Loading...
  • 39
    By name of foreign product
    Loading...
  • 523
    Names
    Loading...
  • 3998
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3998 products
E-meter AT-005 Electric Field Parameter meter
E-meter AT-005 Electric Field Parameter meter
from 40 500 ₽
Designed for measuring the average square values of the electric field strength in the frequency range from 10 kHz to 30 MHz in continuous generation mode.
Produced in: Moscow
rhHGF 728AA
rhHGF 728AA
from 14 000 ₽
Human hepatocyte growth factor - participates in the processes of morphogenesis and regeneration, stimulation of the survival of hepatocytes, tubular cells of the kidneys, neurons.
Produced in: Moscow
AF011B Microassembly
AF011B Microassembly
A high-speed signal limiter amplifier. Designed for use in electronic counting frequency meters. Description: The magnitude of the input signals for selecting the switch input and inverting the signal of the limiter amplifier at a supply voltage of ± 5 V: - logical "0" not more than 0.2 V; - logical "1" at least 4.8 V. The value of the input signals of switching on / off the switch at a supply voltage of ± 5 V: - logical "0" no more than 3.3 V; - logical "1" at least 4.1 V. The magnitude of the output signals of the switch at a supply voltage of ± 5 V and a load of 300 ohms connected to zero potential: - logical "0" from 3.1 V to 3.4 V; - logical "1" from 4.0 V to 4.3 V. The minimum input voltage of the sinusoidal shape in the frequency range from 10 Hz to 200 MHz should be no more than 30 mV. The maximum input voltage of the sinusoidal shape in the frequency range from 10 Hz to 200 MHz must be at least 1 V. The value of the supply voltage: - positive 5±0.2 V; - negative -5±0.2 V. The current consumption should be no more than: - from a positive power source 110 mA; - from a negative power supply 35 mA.
MNIPI
Minsk
Produced in: Belarus, Minsk
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
1 supp.
Technical specifications: The upper limit of the measurement range is 5 mg/kg Analysis time 1-5 min Permissible sample weights are 10-500 mg The weight of the console is 17 kg Air pumping speed 1-3 l/min Dimensions and weight of the analyzer 470x210x110 mm; 7.5 kg Power supply of the PIRO-915+ 220 V, 700 W Analyzer power supply 220 V, 15 W Dimensions of the power supply and pumping unit no more than 400x280x135 mm The dimensions of the thermal camera unit and the remote optical unit are no more than 430x340x135 mm The upper limit of the measurement range for sample weighting is 20 mg 200 mg/kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-105a
Circulation thermostat LT-105a
The LOIP LT-105a modification device consists of an immersion thermostat-circulator LOIP LT-100 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +100 with tap water cooling °C Tvods+5 ...+100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, 0.17 bar Bath volume, l 5 The working fluid is water, water-glycerin mixture. The open part of the bath / depth, mm 120x150/150 Overall dimensions, mm 180x335x370 Weight, kg 6.5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with separating gel, 4 ml, 13×75 mm, red, glass, pack.100 pcs,
Vacuum tube MiniMed with separating gel, 4 ml, 13×75 mm, red, glass, pack.100 pcs,
from 1 208 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Metolab 452 Vickers Hardness Tester
Metolab 452 Vickers Hardness Tester
METOLAB 452 is a stationary Vickers hardness tester – a modification of the METOLAB 451 device with a large color display and improved characteristics. The METOLAB 452 hardness tester is designed to measure the hardness parameters of steels, cast iron, non-ferrous metals, soft alloys and other similar materials on the HV scale in full compliance with GOST R ISO 6507-1-2007. The device has excellent accuracy and provides high repeatability of measurements. METOLAB 452 is a stationary hardness tester equipped with an automatic loading system, as well as a digital display. Thanks to the software of the device, switching from the indenter to the lens also occurs in automatic mode. Other features of the hardness tester include software calculation of hardness values, statistical processing of results (calculation of average/maximum/minimum values), conversion of results into Vickers, Brinell, super-Rockwell scales. The automatic METOLAB 452 Vickers hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) and comes with a certificate of primary verification (on request). The entry number in the GRSI is 67656-17. Distinctive features of the automatic stationary METOLAB 452 Vickers hardness tester: Simple and intuitive interface, full Russification of the device; Wide range of measured values – from 5 to 2500 HV; Wide range of applied test load: 1 kg (9.8 N); 2 kg (19.61 N); 3 kg (29.4 N); 5 kg (49 N); 10 kg (98 N); 20 kg (196.1 N); 30 kg (294 N); 50 kg (490 N); The functionality of converting the obtained values into a number of scales: HRA, HRB, HRC, HRD, HRF, HV, HK, HBW, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T; Automatic switch of the applied load; Large and bright LCD display; Automatic switching from the indenter to the lens; U disk for saving data in Excel format for easy editing and processing; Digital calibration. Basic delivery package: Stationary METOLAB 452 hardness tester; Standard Vickers hardness test - 2 pcs.; Flat desktop; Large flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle at the top of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow
High-voltage test unit UPU-22
High-voltage test unit UPU-22
Technical specifications: Output voltage (DC and AC), 0 - 2 kV; 0 - 5 kV Built-in AC power supply, 10 - 25 A The amplitude value of the DC voltage ripple relative to the set output voltage of 5 kV at idle is not more than ± 5% Error in setting the output voltage, ± 3% Protection tripping current, 101 -- 140 mA Load current of DC and AC output voltage, not less than 1 mA The limit of measuring the resistance of the integrity of the circuit connection, 0, 01 – 0.10 ohms
MNIPI
Minsk
Produced in: Belarus, Minsk
Fume Cupboard SHV-NRZH.100
Fume Cupboard SHV-NRZH.100
Overall dimensions with raised protective shield 1005x800x2270 mm Overall dimensions with lowered protective screen 1005x800x2100 mm The diameter of the exhaust pipe is 200 mm Weight 160 kg Power supply 220 V, 50 Hz, 16 A
Produced in: Tomsk
MEASURING AND COMPUTING COMPLEX "VULKAN-2005M" AND "VULKAN-2005M1 VACUUM TESTER"
MEASURING AND COMPUTING COMPLEX "VULKAN-2005M" AND "VULKAN-2005M1 VACUUM TESTER"
The measuring and computing complex "Vulkan-2005M" and "Vulkan-2005M1 Vacuum Tester" are designed to measure the pressure of vapors and gases in a given volume when determining the thermal stability of substances in the isothermal mode, carried out according to the certified methodology of the customer, developed specifically for each substance. The CPI is included in the State Register of Measuring Instruments. technical specifications The measurement range of barometric pressure is from 86.6 kPa to 106.7 kPa. The absolute pressure measurement range should be from 5 kPa to (Ratm. +250) kPa, where Ratm. – atmospheric pressure. The limit of permissible error of pressure measurement does not exceed the values of: – barometric - ± 0.5 kPa. – overpressure - ± 2.0 kPa. – total (barometric + excessive) - ± 2.5 kPa. The temperature range in the reaction volumes of primary converters is from +50 to +280 °With the use of reusable fluoroplastic gaskets, from 280 to 400℃ with the use of disposable aluminum gaskets. Instability of maintaining the set temperature in thermostats for 10 minutes no more than ± 0.1 ° C. The discreteness of setting the temperature of temperature control is 0.1 ° C. The error of setting the temperature of temperature control does not exceed ± 2 ° C. The total volume of the glass is 20 ml. Minimum vacuum: 5 kPa. The IVC consists of up to 4 thermostats with primary converters, 8 in each thermostat. The time interval between measurement cycles in automatic mode is 1 second. The emergency protection is triggered when the values, pressure or temperature set in the control program are exceeded. The hardware overheat protection of the thermostat is triggered when the maximum operating temperature of the complex is exceeded. The IVC is powered from an AC mains voltage of 220V with an acceptable deviation from minus 15% to +10% frequency (50 + 1) Hz with a coefficient of nonlinear distortion of no more than 5%. The output time of the thermostats to the mode from the moment they are turned on does not exceed 3.5 hours. The power consumption of the CPI, no more than 4 kW. Overall dimensions of one thermostat, (width × depth × height), no more than -450×460×600mm. The weight of one thermostat, no more than 32 kg. The continuous operation time of the CPI is at least 72 hours.
Produced in: Yoshkar-Ola, Mari El