Search

3998 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 23
    Foreign brand
    Loading...
  • 39
    By name of foreign product
    Loading...
  • 523
    Names
    Loading...
  • 3998
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3998 products
CF Corrugated hoses
CF Corrugated hoses
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
AC voltage source B2-9
AC voltage source B2-9
The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET. Technical specifications Output voltage setting range (SCR) from 25 to 250 V The discreteness of the output voltage setting is 0.05 V The frequency setting range of the output voltage is from 40 to 500 Hz The discreteness of the output voltage frequency setting is 0.05 Hz Output electrical power, not less than 1000 VA The basic error of setting the output voltage is ± (0.005 Uv + 0.5 V) The basic error of setting the output voltage frequency is ± 0.1 Hz Additional error in setting the output voltage caused by a change in the load current from the maximum value to zero ± 0.5 V Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 0.5 V Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 1300 VA Overall dimensions, mm 343x160x352 Weight, not more than 6.5 kg
Produced in: Moscow
Tablet for slides for 20 places, p/s, ind.up.
Tablet for slides for 20 places, p/s, ind.up.
from 195 ₽
Designed for drying and storage of slides measuring 76x26 mm in research laboratories. Made of polystyrene.
MiniMed
Suponevo
Produced in: Bryansk region
Low wall-mounted laboratory table SL-90.80.76
Low wall-mounted laboratory table SL-90.80.76
The table is 760 mm high with a 900×800 mm countertop made of porcelain stoneware, monolithic ceramics, stainless steel, chipboard or plastic. Designed for sitting work. It can be equipped with various superstructures, sliding and hanging bollards. Overall dimensions 900x800x760 mm
Produced in: Tomsk
Conical tube 19/26,n/a, pack of 10 pcs
Conical tube 19/26,n/a, pack of 10 pcs
from 225 ₽
Designed for capping various laboratory utensils.
MiniMed
Suponevo
Produced in: Bryansk region
MS-10 Magnetic Structuroscope
MS-10 Magnetic Structuroscope
from 270 000 ₽
Distinctive features: - Non-destructive testing of strength, plasticity and viscosity of parts and structures made of ferromagnetic steels and cast iron according to the following standards: GOST 30415-96, OST 14-1-184-65, TU-14-1016-74 - Non-destructive testing of the depth and hardness of surface-hardened layers on steel and cast iron parts; - Quality control of low-temperature tempering of cutting and measuring tools, bearing steels; - Control of uniaxial elastic stresses; - Control of the uniformity of the properties of massive parts. Technical specifications: The range of coercive force of the material of the controlled products, A/cm, is 1.0...60. The limit of the permissible basic absolute error of measurements of the coercive force (Ns) on standard samples at a normal ambient temperature of 20 ± 5°C does not exceed the values of 0.1+0.04 Ns (Ns stands for the measured value of the coercive force of the standard sample). This error probability is provided with a gap between the converter and the surface of the controlled product not exceeding 0.5 mm. Basic version: The structroscope is powered by a battery. Extended version: It is possible to work on 220V/50Hz grid. The time of setting the operating mode after power on, min: no more than 2 Time of one measurement, sec: no more than 6 Continuous operation time (without recharging), h: at least 16 Internal memory: up to 512 series of 512 measurements each with the possibility to view the results Operating temperature range: -20°C to +40°C; Overall dimensions, (length x width x thickness), mm: electronic unit: 190x140x80 converter: 135x75x100 Weight, kg: the electronic unit with a battery: 2.3 ± 0.05 the converter: 1.3± 0.05 Basic version kit: Ia5.173.023 Electronic unit: 1 pc. Ia5.125.061 Converter: 1 pc. Ia8.896.121 Control sample of coercive force (plate PN-1): 1 pc. Ia8.896.122 Control sample of coercive force (plate PN-2): 1 pc. Bag-case: 1 pc. Charger: 1 pc. Ia2.778.042 RE Operating Manual: 1 copy. Ia2.778.042 FO Form: 1 copy. Ia2.778.042 MP Verification instructions: 1 copy. Extended version: Additionally, it can be equipped with a Bluetooth® module for communication with a PC and software for receiving and processing data. It can also be equipped with a small-sized converter.
Produced in: Moscow
Table-sink LAB-800 MO
Table-sink LAB-800 MO
The table top is a single module made of stainless steel SUS 201 (analog AISI 201) ATTENTION! The product is recommended to be used only for work with non-aggressive substances. inner bowl size – 340*400* 130mm cabinet body – melamine 16mm thick
LOIP
Saint Petersburg
Produced in: Saint Petersburg
CFx-x10 neoptic closed cycle cryostat by Cryopribor
CFx-x10 neoptic closed cycle cryostat by Cryopribor
The sample is kept in a vacuum. The closed cycle of work allows to refuse completely liquid refrigerants (nitrogen and helium). Of the additional equipment for the operation of the cryostat, only a temperature controller and a vacuum pump (vane-rotary or spiral, or turbomolecular pumping station) are required. This cryostat model does not have any means of vibration suppression - they are transferred to the sample directly from the cryocooler, and depending on the model used, the approximate value of vibrations on the sample is from 20 to 200 microns. Applications: – Electrical and magnetic experiments; – Thermal, electrical and magnetic susceptibility; – heat capacity; – DLTS (deep level transient spectroscopy, deep level spectroscopy); – Observation of the Seebeck effect.
Produced in: Moscow
Vacuum tube MiniMed with lithium heparin, 9 ml, 16×100 mm, green, PET, pack.100 pcs.
Vacuum tube MiniMed with lithium heparin, 9 ml, 16×100 mm, green, PET, pack.100 pcs.
from 1 755 ₽
Test tubes are used to count blood cells and study plasma parameters. When mixed with the collected material, heparin blocks the activity of thrombin and inhibits the transition of soluble fibrinogen to insoluble fibrin, inactivating irreversible clotting factors. Research material............... heparinized blood, plasma Scope of application............................ immunology, hematology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
UCHX2-78
UCHX2-78
Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low phase noise value; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 26,78-39,17 / 53,57-78,33 Losses (max.), dB 15 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 2.0 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 2.4/1.0 mm (plug/socket) • Output Waveguide 3,759x1,88 mm (50-75GGo) Overall dimensions, mm 26x20x20 Weight, g 50
Produced in: Moscow