Universal frequency meter Ch3-92
Universal frequency meter Ch3-92
The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (0.3 – 37.5) GHz Pulse duration 10 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Frequency measurement resolution 2x10-10 s/Rng The range of setting the trigger levels (inputs A, B) from minus 2.5 to 2.5 V The error of setting the trigger levels (inputs A, B) ± 0.05 V Input signal level: • for sinusoidal signal (inputs A, B) (0.03 - 10.0) V • for video pulse signal (inputs A, B) (0.1 - 10.0) V • for sinusoidal signal (input C) 50 MW - 5 MW Input resistance • Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF • Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 299x136x436,5 Weight, not more than 8.5 kg
Produced in: Moscow
Metolab 101 Rockwell Hardness Tester
Metolab 101 Rockwell Hardness Tester
METOLAB 101 is an analog stationary hardness tester according to the Rockwell method, a modification of the METOLAB 100 hardness tester with an electromechanical loading system. The rest of the devices are identical. The stationary METOLAB 101 hardness tester is designed to measure the hardness of various materials using the Rockwell method, HRA, HRB and HRC scales. Due to its ease of operation, the stationary METOLAB 100 hardness tester can find its application in a wide variety of industries and production, as well as in educational institutions of various levels in the training of specialists. The stationary METOLAB 101 Rockwell hardness tester is included in the State Register of Measuring Instruments of Russia (GRSI) and comes with a certificate of primary verification (on request). The number in the GRSI is 65128-16. Distinctive features of the stationary METOLAB 101 Rockwell hardness tester: Simplicity and convenience in both operation and maintenance; Wide range of measured values; High degree of reliability; Low cost of measurements compared to competitors. Basic delivery package: Stationary METOLAB 101 hardness tester; Indenter with a ball (1.5875 mm) - 1 pc.; Conical diamond indenter (120°) - 1 pc.; Flat table SP1 (60 mm); V-shaped prismatic table SRP1 (40 mm); Rockwell hardness measures - 1 set; User Manual. Additional information: GOST standards and regulatory documents establishing requirements for the METOLAB 101 Rockwell hardness tester: GOST 8.064-94 GSI. State verification scheme for hardness measuring instruments on the Rockwell and Super-Rockwell scales; GOST 9013-59 Metals and alloys. Rockwell hardness measurement method. Scales A, B, C; GOST 22975-78 Metals and alloys. Rockwell hardness measurement method at low loads (Super-Rockwell); GOST 23677-79 Hardness testers for metals. General technical requirements.
Metolab
Moscow
Produced in: Moscow
CF bellows
CF bellows
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
NV-1200 VG Anti-vibration table for scales (1200×600×750)
NV-1200 VG Anti-vibration table for scales (1200×600×750)
from 15 447 ₽
The NV-1200 VG is a specialized laboratory table with a damping concrete slab on a sand cushion. It is designed to accommodate sensitive analytical equipment, primarily scales. Dimensions when assembled: 1200×600×750 mm. It is designed to work while sitting. The table has a reinforced metal frame. The main countertop has a built-in drawer open from above, which contains a sand cushion. It is closed with a heavy concrete slab attached to a second, smaller countertop. The sand cushion and the concrete base of the second countertop provide good protection against vibrations. Working surface material: laminate. It is well suited for the placement of devices, but is not resistant to concentrated acids, alkalis and organic solvents. The size of the anti-vibration countertop: 400×400 mm. For maximum isolation from vibrations, the scales should be placed in the center of this countertop. The tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard 16 mm thick) are edged with a durable PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Media Converter SFP - SFP MCSFP2 - SFP
Media Converter SFP - SFP MCSFP2 - SFP
from 2 193 ₽
A media converter is used as a converter that converts one signal transmission medium into another. The data transmission medium means optical and copper cable. The scope of application – FastEthernet and GigabitEthernet protocols, STM-1 and STM-4. Media converters are characterized by a number of parameters, by setting that you can choose the optimal network equipment for solving a specific task. The possibility to control the device; Installation location; Properties of the optical receiver-transmitter; Supported transfer rate.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with coagulation activator, 4ml, 13×75mm, orange, PET, pack.100 pcs,
Vacuum tube MiniMed with coagulation activator, 4ml, 13×75mm, orange, PET, pack.100 pcs,
from 690 ₽
The walls of the tubes are coated with a dry clot formation activator (silicon dioxide) to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Spectrometer SPECTROSCAN MAX-GVM
Spectrometer SPECTROSCAN MAX-GVM
The spectrometer is designed to determine the contents of elements in the range from Na to U in substances in solid, powdery, dissolved states, as well as deposited on the surface or deposited on filters. The principle of operation of the X-ray spectrometer is based on irradiation of the sample with primary radiation from an X-ray tube, measurement of the intensity of secondary fluorescent radiation from the sample at wavelengths corresponding to the elements to be determined, and subsequent calculation of the mass fraction of these elements according to a pre-constructed calibration characteristic, which is the dependence of the content of the element to be determined on the measured intensity. Secondary fluorescent radiation is decomposed into a spectrum using a crystal analyzer. Due to this, the X-ray fluorescence spectrometer has a high resolution, and therefore the ability to accurately analyze complex multicomponent substances.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Laboratory island low table CO-150.128.76
Laboratory island low table CO-150.128.76
The table is 760 mm high with two countertops measuring 1500×640 mm each. Countertops made of granite, monolithic ceramics, stainless steel, chipboard or plastic. It is designed for sitting work. It can be equipped with various superstructures, sliding and hanging bollards. Overall dimensions 1500x1280x760 mm
Produced in: Tomsk
Muffle furnace LF-7/13-V1
Muffle furnace LF-7/13-V1
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x285 mm Overall dimensions, WxHxD, not more than mm 505x955x655 Rated supply voltage, 220 V Rated power, W 3300
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Contact thermometer TK-5.01PTS
Contact thermometer TK-5.01PTS
from 16 560 ₽
The digital contact thermometer TK-5.01PTS is designed to measure the temperature of the surface of solids by direct contact of the probe with the measuring object. The digital contact thermometer consists of an electronic unit and a non-replaceable surface probe. Thermoelectric converters (TP) with NSH according to GOST R 8.585 are used as a thermosensitive element in the probe.
Produced in: Moscow
Explosion-proof drying cabinet SNOL-90
Explosion-proof drying cabinet SNOL-90
from 447 168 ₽
Explosion-proof drying cabinet SNOL-90 is designed for drying, tempering, aging, thermal testing and other types of heat treatment of various materials in an air environment at temperatures up to 240 ° C with natural or forced air convection in stationary conditions. The environment is a potentially explosive mixture of air and gases, vapors, mists of categories IIA and IIB.