Search

3941 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Areas of use
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 41
    By name of foreign product
    Loading...
  • 550
    Item names
    Loading...
  • 3941
    Russian analogue
    Loading...
  • 24
    Areas of use
    Loading...
  • 132
    Manufacturer
    Loading...
View:
3941 products
DWDM Modules
DWDM Modules
DWDM SFP transceivers support various data transfer protocols, ranging from OS-3/STM-1/SDH/FE to 10GBE/OC-192/10FC/STM-64. All Optronic DWDM transceivers are equipped with DDM (Didgital Diagnostic Monitoring). This function allows you to control the parameters of optical modules: output signal power, input signal power, temperature characteristics of the transceiver, as well as supply voltage and consumption current. The data is transmitted in real time.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with K2-EDTA and separation gel, 1ml, 13×75mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA and separation gel, 1ml, 13×75mm, purple, PET, pack.100 pcs,
from 858 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
conductometer MARK® 602
conductometer MARK® 602
Measurement of electrical conductivity (UEP, UEP25) and salinity of aqueous media, including "ultrapure". Control of water-chemical regimes at thermal and nuclear power facilities. Specialized water treatment.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Double automatic thermal compensation. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Basket MT-21-K
Basket MT-21-K
The basket with a lid is designed to accommodate unambiguous measures of electrical resistance in the MT-21 thermostat during their verification and calibration in accordance with GOST 8.237. Internal dimensions 103x170 mm Weight 0.3 kg
Produced in: Tomsk
rhVEGF-A165
rhVEGF-A165
from 6 600 ₽
Vascular Endothelial Growth Factor is one of the key regulators of angiogenesis. The most important role in the human body is played by a protein of the VEGF family called VEGF-A. VEGF-A is a 45 kDa glycoprotein homodimer and plays a key role in chemotaxis and angioblast differentiation, endotheliocyte (EC) proliferation, vasculogenesis, and vascular remodeling. As a result of alternative splicing or proteolytic cleavage, 4 main isoforms of VEGF-A are formed, consisting of 121, 165, 189, or 206 amino acid residues.
Produced in: Moscow
PM-8 verification module
PM-8 verification module
The composition of the PM-8 verification module Frequency comparator CHK7-1011; Universal frequency meter Ch3-89; AC voltage voltmeter VK3-78A; Universal voltmeter V7-81; AC voltage calibrator H5-5; High-frequency signal generator G4-227; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Absorbed power wattmeter M3-108; Installation for measuring attenuation D1-24/1; Device for measuring attenuation stepwise D1-25; Computational modulation meter SK3-49; The meter-calibrator of the harmonic coefficient SK6-20; Spectrum analyzer SK4-"Belan 240"; VSWR panoramic meter R2-135; VSWR panoramic meter R2-137; A set of exemplary measures of the transmission coefficient H3-7; Oscilloscope S1-157/4; DC power supply B5-79/1; AC power source B2-7 (2 pcs.); Electronic switch of microwave signals; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage from 3 MV to 1000 V Alternating electric voltage in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Frequency of continuous electromagnetic oscillations from 0.001 Hz to 17.85 GHz The power of continuous electromagnetic oscillations in the frequency range of 20 MHz ... 17.85 GHz from 0.8 to 10 MW Attenuation of electromagnetic oscillations in the frequency range 0.1 MHz ... 17.85 GHz from 0 to120 dB VSWR in the frequency range 0.2 ... 17.85 GHz from 1.03 to 2 Harmonic coefficient in the frequency range of 10 Hz ... 8 GHz from 0.005 to 100 % The amplitude modulation coefficient in the carrier frequency range of 100 kHz ... 17.85 GHz from 0.1 to 100 % Frequency deviation in the carrier frequency range of 100 kHz ... 17.85 GHz from 5 Hz to 1 MHz Phase modulation index in the carrier frequency range 100 kHz ... 17.85 GHz from 1 to 100 radians Phase shift between two harmonic signals in the frequency range 0.1 MHz ... 17.85 GHz from 0 to 360o Ranges of reproduction of electrical quantities: Alternating electrical voltage in the frequency range of 10 Hz ... 2000 MHz from 3 MV to 3 V Harmonic (sinusoidal) signal at a load of 50 ohms in the frequency range of 0.001 Hz ... 30 MHz from 0.01 to 5 V Continuous electromagnetic oscillations in the frequency range of 9 kHz ... 17.85 GHz from minus 120 to 13 dBm 5 and 10 MHz reference frequency signal Attenuation of electromagnetic oscillations in the frequency range 0 ... 3 GHz from 0 to 86 dB Measurement errors of electrical quantities: Constant electrical voltage ± (0.0025 ... 16.7) % Alternating electric voltage in the frequency range 10 Hz ... 2000 MHz ± (0.2 ... 16) % Frequency of continuous electromagnetic oscillations ± (2·10-7 ... 4·10-3) Power of continuous electromagnetic oscillations in the frequency range 20 MHz ... 17.85 GHz ± (4 ... 6) % Attenuation of electromagnetic oscillations in the frequency range 0.1 MHz ... 17.85 GHz ± (0.01 ... 1.2) dB VSWR in the frequency range 0.2 ... 17.85 GHz ± (3 ... 5) K Harmonic coefficient in the frequency range 10 Hz ... 8 GHz ± (0.005 ... 6) % Amplitude modulation coefficient in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.1 ... 9) % Frequency deviation in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.2 ... 80) Hz Phase modulation index in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.02 ... 5) radians Phase shift between two harmonic signals in the frequency range 0.1 MHz ... 17.85 GHz ± (0.01 ... 0.08) o Errors in the reproduction of electrical quantities: Alternating electrical voltage in the frequency range 10 Hz ... 2000 MHz ± (0.16 ... 10) % Harmonic (sinusoidal) signal at a load of 50 ohms in the frequency range 0.001 Hz ... 30 MHz ± (3 ... 5) %; Continuous electromagnetic oscillations in the frequency range of 9 kHz ... 17.85 GHz ± (0.5 ... 3) dB 5 and 10 MHz reference frequency signal ± (2·10-11 – 2,4·10-10) Attenuation of electromagnetic oscillations in the frequency range 0 ... 3 GHz ± (0.2 ... 1.4) dB General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 550 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 3000 VA
Produced in: Moscow
Metal single support pedestal with door LAB-PRO TOMA3 54.50.86
Metal single support pedestal with door LAB-PRO TOMA3 54.50.86
Metal single support cabinet with 3 drawers Length, mm: 540 Depth, mm: 500 Height, mm: 860 Completely made of powder-coated steel (RAL 7035) with the texture of shagreen leather Frameless housing design One compartment with 3 drawers The side walls and facades are double. The thickness of the side walls is 19 mm, the facades are 18 mm The facades are filled with noise-absorbing material Lock in the top drawer Handles – polypropylene Telescopic guides of full extension Internal size of drawers: upper and middle – 460*410*85 mm, lower – 460*410*295 mm The permissible load on the box is 30 kg Hidden adjustable supports (0 - 40 mm). The adjustment of the supports is carried out from inside the pedestal through the base. 8 standard variants of LAB-PRO RP work surfaces
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Radiation monitoring system "Frigate"
Radiation monitoring system "Frigate"
A simple and inexpensive radiation monitoring system for radiation-hazardous facilities, such as radionuclide source storages, isotope warehouses, clinical radionuclide diagnostics and therapy departments, PET centers, metrological laboratories where work with ionizing radiation sources is carried out, etc.
Doza
Zelenograd
Produced in: Moscow
Vacuum Spectrometer Favorite
Vacuum Spectrometer Favorite
Vacuum spectrometers are designed for rapid analysis of alloys based on iron, copper, aluminum and other metals in factory and research laboratories, including the determination of elements having analytical lines in the field of vacuum ultraviolet (VUV) (for example, S, P and C in steels).
Produced in: Novosibirsk
VT5 Liquid thermostat
VT5 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external closed-type consumers. Feed pump for external closed-type thermostating systems. All-metal stamped tub with a volume of 5 liters and a depth of 200 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. The volume of the bath is 5 liters Overall dimensions 170x350x480 mm The open part of the bath is 75x35 mm Bath depth 200 mm Weight 11 kg Power consumption 2.2 kW
Produced in: Tomsk
MS-10 Magnetic Structuroscope
MS-10 Magnetic Structuroscope
from 310 500 ₽
Distinctive features: - Non-destructive testing of strength, plasticity and viscosity of parts and structures made of ferromagnetic steels and cast iron according to the following standards: GOST 30415-96, OST 14-1-184-65, TU-14-1016-74 - Non-destructive testing of the depth and hardness of surface-hardened layers on steel and cast iron parts; - Quality control of low-temperature tempering of cutting and measuring tools, bearing steels; - Control of uniaxial elastic stresses; - Control of the uniformity of the properties of massive parts. Technical specifications: The range of coercive force of the material of the controlled products, A/cm, is 1.0...60. The limit of the permissible basic absolute error of measurements of the coercive force (Ns) on standard samples at a normal ambient temperature of 20 ± 5°C does not exceed the values of 0.1+0.04 Ns (Ns stands for the measured value of the coercive force of the standard sample). This error probability is provided with a gap between the converter and the surface of the controlled product not exceeding 0.5 mm. Basic version: The structroscope is powered by a battery. Extended version: It is possible to work on 220V/50Hz grid. The time of setting the operating mode after power on, min: no more than 2 Time of one measurement, sec: no more than 6 Continuous operation time (without recharging), h: at least 16 Internal memory: up to 512 series of 512 measurements each with the possibility to view the results Operating temperature range: -20°C to +40°C; Overall dimensions, (length x width x thickness), mm: electronic unit: 190x140x80 converter: 135x75x100 Weight, kg: the electronic unit with a battery: 2.3 ± 0.05 the converter: 1.3± 0.05 Basic version kit: Ia5.173.023 Electronic unit: 1 pc. Ia5.125.061 Converter: 1 pc. Ia8.896.121 Control sample of coercive force (plate PN-1): 1 pc. Ia8.896.122 Control sample of coercive force (plate PN-2): 1 pc. Bag-case: 1 pc. Charger: 1 pc. Ia2.778.042 RE Operating Manual: 1 copy. Ia2.778.042 FO Form: 1 copy. Ia2.778.042 MP Verification instructions: 1 copy. Extended version: Additionally, it can be equipped with a Bluetooth® module for communication with a PC and software for receiving and processing data. It can also be equipped with a small-sized converter.
Produced in: Moscow