Search

3960 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Areas of use
    Loading...
All filters
  • 21
    Foreign brand
    Loading...
  • 39
    By name of foreign product
    Loading...
  • 553
    Item names
    Loading...
  • 3960
    Russian analogue
    Loading...
  • 24
    Areas of use
    Loading...
  • 132
    Manufacturer
    Loading...
View:
3960 products
PKV-IP-5,2×2,6
PKV-IP-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow
DOSIMETER‑RADIOMETER ISS‑AT1117M (ALPHA/BETA POLLUTION MONITORS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (ALPHA/BETA POLLUTION MONITORS)
High sensitivity Sound, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions A wide range of measurements
Produced in: Belarus, Minsk
Vacuum tube MiniMed with sodium citrate 3.2%, 2.7 ml,13*100 mm, blue, PET,pack.100 pcs,
Vacuum tube MiniMed with sodium citrate 3.2%, 2.7 ml,13*100 mm, blue, PET,pack.100 pcs,
from 693 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Sliding cabinet LAB-400 TVYA-3
Sliding cabinet LAB-400 TVYA-3
Furniture for laboratory work. Sliding cabinet Length, mm: 400 Depth, mm: 580 Height, mm: 830 PACKAGE CONTENTS case – melamine 16mm thick inner size of the box – 310*470* 180mm roller supports h=60mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Island LAB table-2400 OTM
Island LAB table-2400 OTM
equipment 2 countertops sink-drain (polypropylene, internal size 250*100*150mm), laboratory faucet d/water the package includes a siphon gofroslang flexible eyeliner length 1200mm 2 racks, each support racks – aluminum profile painted with powder paint (RAL 1001) top panel 190mm deep – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
VD-90NP Eddy current flaw detector in the basic configuration
VD-90NP Eddy current flaw detector in the basic configuration
from 398 250 ₽
The principle of operation of the device: The principle of operation of the flaw detector is based on the excitation of eddy currents in the controlled product and the subsequent release of a signal at the output of the converter, the amplitude and phase of which are determined by the secondary field of eddy currents. Design features and advantages of the VD-90NP flaw detector. The device has a small-sized case, which ensures its lightness, ergonomics and allows you to mount it on your belt or on your arm. The measurement is performed using a remote converter connected by a flexible cable. There are several types of converters for eddy current flaw detection of products made of different materials and different geometries. The large and bright display displays the selected operating modes and measurement results in text and graphic form. The VD-90NP is also characterized by: high sensitivity (it detects cracks starting from 0.1 mm in size); dust–and-moisture-proof housing, which makes it applicable for work in the field; large operating frequency range; maximum working clearance up to 10mm; Bluetooth connection; the ability to control products with high surface roughness, up to Rz320 class; light and sound indication of defect detection; wide operating temperature range from –30°C to +50°C; autonomous low-voltage power supply; long continuous operation time from one set of batteries; compliance with the standard GOST R ISO 15549-2009 (ISO 15549:2008). The use of a microprocessor-based hardware and software platform provide it with the following operational characteristics: automatic adjustment when measuring conditions change, including compensating the influence of the gap; built-in calibration modes; saving the measurement results in the internal memory of the device; a large number of stored programs: sets of parameters and measurement modes, both preset and saved by the user so as to repeatedly monitor the same type of products; The Bluetooth 2.0 wireless communication module allows the device to be used in conjunction with an external laptop or mobile device for remote control, transmission of measurement results for further storage, printing, documentation and analysis. Scope of application: The eddy current method is suitable for non-destructive testing and detection of microcracks in products and parts made of any metals and alloys of complex shape, with high surface roughness, through non-conductive coatings, as well as for checking welded joints. The flaw detector can be used to control parts and assemblies of aviation equipment. The VD-90NP eddy current flaw detector is used for quality control and preventive examination of: - components and parts of rolling stock at railway transport enterprises: wheel sets, auto coupler housings, side frames, spring beams, labyrinth rings, pulleys; - pipes, profiles, rods at rolling mills at the output control, and at the input control of consumers of products; - products made of aluminum and titanium alloys with multilayer coatings at enterprises of the aviation and aerospace industry; - cables, beams, critical components of equipment (cranes, lifts) in construction; - main pipelines in order to detect stress corrosion. A wide range of operating temperatures, dust and moisture protection (IP54 degree of protection), autonomous low-voltage power supply, a long time of continuous operation of the device allows it to be used in the field at low temperatures and under precipitation (rain, snow). Basic kit: • 1 electronic unit for the VD-90NP eddy current flaw detector; • 1 Ia5.125.052 (Type-2) eddy current converter; • 1 converter cable; • 1 charger with batteries; • 1 hand strap; • 1 Ia8.896.104 sample with artificial defects; • 1 Ia8.896.035 coating sample; • 1 storage and carrying case; • 1 documentation set.
Produced in: Moscow
Blue DPSS Laser 445nm KLM-445-x
Blue DPSS Laser 445nm KLM-445-x
DPSS lasers of the KLM-445/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes. Technical specifications Radiation output power: up to 120W Radiation wavelength: 445 nm Output beam diameter: 1.5mm Divergence of the radiation beam: 1.3 mrad Instability of radiation power: 5% Type of modulation: TTL or analog Time to enter the mode: 15min Spectral line width: 0.1nm
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Island table low LAB-PRO SOCN 180.150.75 KG-ESS
Island table low LAB-PRO SOCN 180.150.75 KG-ESS
Island table Combined work surface: main countertop KG-ESS 650 mm deep/ auxiliary table top made of TRESPA material with a depth of 200 mm / main table top KG-ESS with a depth of 650 mm Length, mm: 1800 Depth, mm: 1500 Height, mm: 750 BASIC EQUIPMENT The base is a collapsible metal frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Four easily removable screens (RAL 7035) and two non-removable (RAL 5023) Hidden fasteners Adjustable supports (0-40 mm) A set of end boxes-plugs
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Glass wand, length 220 mm
Glass wand, length 220 mm
from 810 ₽
Designed for mixing inviscid solutions
MiniMed
Suponevo
Produced in: Bryansk region
VLA-135M comparator scales
VLA-135M comparator scales
from 499 990 ₽
Technical specifications NIP, g135 Discreteness, g0,00001 Self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0,001 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.001g to 50g incl. ± 0.5; sv. 50g to 135g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special Actual typical error limits of the scales, mg *± 0.1 in the entire range The setting time, s, no more than ~ 6 Overall dimensions of the scales (LxWxH), mm411x212x345 7 years warranty Weight of the scales, kg, not more than 7.9 The weight adjustment is built-in Price with VAT, RUB 359,990
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Island high LAB table-PRO SOKv 90.150.90 KG-ESS
Island high LAB table-PRO SOKv 90.150.90 KG-ESS
Island table Combined work surface: main countertop KG-ESS 650 mm deep / auxiliary table top made of TRESPA material with a depth of 200 mm / main table top KG-ESS with a depth of 650 mm Length, mm: 900 Depth, mm: 1500 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible metal frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Four easily removable screens (RAL 7035) and two non-removable (RAL 5023) Hidden fasteners Adjustable supports (0-40 mm) A set of end boxes-plugs
LOIP
Saint Petersburg
Produced in: Saint Petersburg