Search

3995 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 22
    Foreign brand
    Loading...
  • 37
    By name of foreign product
    Loading...
  • 522
    Names
    Loading...
  • 3995
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 127
    Manufacturer
    Loading...
View:
3995 products
VAC-52 platform scales
VAC-52 platform scales
from 59 990 ₽
Technical characteristics: NIP, KG52 Discreteness, g10,0 External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g500 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during primary verification, goth 500g to 50 kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 20KGF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with coagulation activator and separation gel, 3.5ml,13*75 mm, yellow-orange, PET, pack.100 pcs
Vacuum tube MiniMed with coagulation activator and separation gel, 3.5ml,13*75 mm, yellow-orange, PET, pack.100 pcs
from 858 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Research material............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
LAB-M MO13 ME 50.60.90 SS
LAB-M MO13 ME 50.60.90 SS
Furniture for laboratory work. WASHING TABLE ON A METAL SUPPORT STAND LAB-M MO13 ME 50.60.90 SS Width, mm: 500 Depth, mm: 600 Height, mm: 900 equipment: The table top is a single module made of SUS 201 stainless steel (analogous to AISI 201). Attention! The product is recommended to be used only for work with non-aggressive substances. For work with various reagents except mineral acids, it is recommended to use washing tables made of AISI 304 stainless steel. the inner size of the bowl: LAB-M MO13 50.60.90 SS – 340*420* 130mm The base of the sink table is a metal support pedestal. The lower part is an all–welded frame painted with dark gray powder paint RAL 7011. The bottom and top of the housing are sheet steel painted with powder paint of dark gray RAL 7011, the side walls are made of sheet steel painted with powder paint of white RAL 9016. Facades – laminated MDF of white color with a thickness of 16 mm, dark gray ABS edging
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Reciprocating shaker LOIP LS-120
Reciprocating shaker LOIP LS-120
Type of motion reciprocating The maximum oscillation frequency of the platform, min-1 250 The amplitude of the platform movement, mm 10 Maximum load on the platform, kg 2 Power consumption, W 50 Platform size, mm 315x210 Overall dimensions, mm 360x310x170 Weight, kg 9
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Cylinder 2-500-2 with glass base and lid
Cylinder 2-500-2 with glass base and lid
from 1 268 ₽
Designed for dispensing volatile liquids. The applied scale of brown or white colors is completely resistant to any influences. TU 9464-013-52876351-2014, GOST 1770-74, pack.2/24 pcs, MiniMedProm Manufactured according to specifications 9464-013-52876351-2014 in accordance with the technical requirements of GOST 1770-74. The products are made of chemical laboratory glass according to GOST 21400. Version 2, accuracy class 2. RU No. RZN 2016/4740 dated 10/25/2021
MiniMed
Suponevo
Produced in: Bryansk region
Metolab 451 Vickers Hardness Tester
Metolab 451 Vickers Hardness Tester
METOLAB 451 is a stationary hardness tester for measuring various materials using the Vickers method (HV scale) in full compliance with GOST R ISO 6507-1-2007. Due to its characteristics, the device allows you to measure the hardness of steels, cast iron, non-ferrous metals, soft alloys and other similar materials. The hardness tester is equipped with an electronic load value switch, has the functionality of entering diagonal length values from the control panel with subsequent automatic calculation of hardness. It is also possible to note a wide range of measured values (from 5 to 2500 HV) and the range of the applied load (from 1 to 50 kg). The automatic METOLAB 451 Vickers hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) and comes with a certificate of primary verification (on request). The entry number in the GRSI is 67656-17. Distinctive features of the stationary METOLAB 451 Vickers hardness tester: Simple and intuitive control of the device; Simplicity and ease of maintenance of the hardness tester; Wide range of measured values – from 5 to 2500 HV; Automatic application of test loads in the range: 1 kg (9.8 N); 2 kg (19.61 N); 3 kg (29.4 N), 5 kg (49 N), 10 kg (98 N); 20 kg (196.1 N); 30 kg (294 N), 50 kg (490 N); The price of dividing the scale of the reference microscope: 0.5 microns at 200x, 1 microns at 100x; The hardness tester is equipped with an electronic load value switch; A bright and clear LCD display that displays all the necessary service information, including the selected scale, the set load, exposure time, test mode, etc.; An automatic loading system guarantees high accuracy and repeatability of the results. Basic delivery package: Stationary METOLAB 451 hardness tester; Standard Vickers hardness test - 2 pcs.; Flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle at the top of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow
LB61-Sh Laboratory bath
LB61-Sh Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Six workstations with a diameter of 110 mm with five steel O-rings, tripods and feet with a clip. Stamped steel bath with a volume of 11 liters and a depth of 60 mm. Bath volume 11 l Overall dimensions 570x660x610 mm The open part of the bath is 500x290 mm Bath depth 60 mm Weight 12.5 kg Power consumption 2.5 kW
Produced in: Tomsk
Muffle furnace LF-5/11-V1
Muffle furnace LF-5/11-V1
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Durable ceramic muffle; Closed heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x190 mm Overall dimensions, WxHxD, not more than mm 505x955x565 Rated supply voltage, 220 V Rated power, W 2800
LOIP
Saint Petersburg
Produced in: Saint Petersburg
PRN-3050-2 Heating plate
PRN-3050-2 Heating plate
Laboratory heating plate with glass-ceramic surface. The size of the heating surface: 300x500 mm. Heating temperature: up to 450 °C. It has two modifications: with built-in and remote control unit.
Produced in: Tomsk
Sulfur Analyzer SPECTROSCAN SW-D3
Sulfur Analyzer SPECTROSCAN SW-D3
The analyzer is designed to determine the mass fraction of sulfur in automotive fuel in accordance with GOST R 52660-2006 / GOST ISO 20884-2016, ASTM D6334, as well as in oil and petroleum products according to GOST R 53203-2008 / GOST 33194-2014, ASTM D2622, GB/T 11140-2008. Depending on the customer's needs, the analyzer is configured to work in accordance with a particular standard. Implements an arbitration method for measuring the mass fraction of sulfur in automobile fuel of the third, fourth and fifth classes. The device is designed specifically for high-quality and fast X-ray fluorescence analysis of fuel in accordance with the technical regulations "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and heating oil", which establishes an arbitration X-ray fluorescence wave dispersion method for determining the mass fraction of sulfur in automotive fuels of the third, fourth and fifth classes. The wave dispersion sulfur analyzer SPECTROSCAN SW-D3 is designed taking into account all the requirements for the process of X-ray fluorescence elemental analysis of low sulfur contents in petroleum products. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of sulfur in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Transitional centering rings (aluminum / stainless steel) with O-ring of circular cross-section
Transitional centering rings (aluminum / stainless steel) with O-ring of circular cross-section
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
Produced in: Kazan