Search

3995 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 522
    Names
    Loading...
  • 127
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 97
    Additional
    Loading...
View:
3995 products
Laboratory washing table SM-90.64.90
Laboratory washing table SM-90.64.90
A table with an overall height of 900 mm with a countertop measuring 900 × 640 mm made of porcelain stoneware, monolithic ceramics or stainless steel. It is designed for long-term operation, the power frame does not contain aluminum and plastic parts in the fasteners. Overall dimensions without superstructure 900x640x900 mm
Produced in: Tomsk
Portable flow meter-sampler of gas-aerosol mixtures PVP-06
Portable flow meter-sampler of gas-aerosol mixtures PVP-06
Purpose measurement and control of the pumping speed and the total volume of the aerosol mixture pumped through the filters installed on the product during sampling in order to determine the content of aerosol pollutants in the air
Doza
Zelenograd
Produced in: Moscow
VOLTAMMETER PARMA VAF-A(M2)
VOLTAMMETER PARMA VAF-A(M2)
It will help relay protection and automation services, the chief power engineer of industrial enterprises and a wide range of specialists engaged in setting up, monitoring, diagnostics and operation of electrical installations to solve the following tasks: − control phase alternation − remove the voltage characteristics − measure phase shift angles and build vector diagrams of voltage and current − control the circuits in the SHPT − check the integrity of electrical conductors − carry out operational maintenance of relay protection circuits and power circuits of electrical installations − monitor the condition and diagnose DC circuits − carry out phasing when setting up differential protection and connecting current and voltage transformers, electric motors − check the correct connection of electricity meters − determine the harmonic composition of current and voltage (up to and including the 19th harmonic)
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-211a
Circulation thermostat LT-211a
The LOIP LT-211a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 11 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 160x240/200 Overall dimensions, mm 268x335x420 Weight, kg 10
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-320S
Analytical scales VLA-320S
from 349 990 ₽
Technical characteristics: NIP, G320 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the calibration division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals: from 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 320g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.45 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 Adjustment weight built - in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
TWO-STAGE THERMAL DESORBER TDS-4
TWO-STAGE THERMAL DESORBER TDS-4
The composition of the TDS-4 includes the thermal desorber itself (the thermostat of the sorption tube, a cryolovushka, an automatic switching valve, a touch control panel), a heated transition line that is installed in the evaporator\ Technical characteristics of TDS-4 Temperature of thermal desorption, 0C to 400 The heating rate of the sorption tube, 0C/min up to 500 Trap temperature, 0C from minus 25 to 400 Trap heating speed, 0C to 2000 The method of heating the trap is direct Tap heating temperature, 0C to 250 Transition line heating temperature, 0C to 250 Continuous operation mode Dimensions of the sorption tube, (diameter; length), mm. Material glass, stainless steel 5/114 (on request 6/115, 6,3/89 and their combinations) Tube material glass or stainless steel (SS316) Method of trap cooling without using liquid refrigerant The number of regulated gas flows is not less than 2 There is an automatic leak test function There is a function of automatic purging of the sorption tube Electric power supply from 187 to 242 V, 50 Hz Power consumption, W not more than 700
Produced in: Yoshkar-Ola, Mari El
WARDROBE MODELS: LK-400 SHG, LK-600 SHG, LK-800 SHG
WARDROBE MODELS: LK-400 SHG, LK-600 SHG, LK-800 SHG
from 15 350 ₽
The 400 mm wide cabinet has one compartment, 2 shelves (bottom and top) and hooks for clothes. The 600 mm cabinet has one compartment, 2 shelves (bottom and top) and a pull-out hanger. The 800 mm cabinet has two compartments, 2 shelves in each (bottom and top) and hooks for clothes. 1. LK-400 SHG Width - 400 CHIPBOARD- 13,590 ₽ STEEL- 27 150 ₽ 2. LK-600 SHG Width - 600 Chipboard- 16 850 ₽ STEEL-32,860 ₽ 3.LK-800 SHG Width - 800 CHIPBOARD- 21,960 ₽ STEEL-42,830 ₽
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
“NanoScan-4D Standard” nanosolidimeter by Nanoscan
“NanoScan-4D Standard” nanosolidimeter by Nanoscan
The basic model of a nanohardness tester that implements the main methods for measuring hardness, Young's modulus, and a number of other mechanical parameters. The nanohardness tester implements the methods of static indentation, dynamic indentation and scratching. It is possible to measure the surface relief in the contact or semi-contact profilometer mode. The presence of an optical microscope ensures high accuracy of the mutual positioning of the indenter and the object of study. Additional components and sensors are available for this model.