Search

159 products
View:
  • Selected: 0
    Areas of use
  • Selected: 1
    Item names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 13
    Areas of use
  • Item names
  • 8
    Manufacturer
  • 9
    Made in
  • 13
    Additional
View:
159 products
CRYO-VT-01 Low-temperature liquid thermostat
CRYO-VT-01 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the liquid coolant circulating in the inner bath. Welded stainless steel bath with a volume of 22 liters. The operating temperature range is -30...+150 °C. Overall dimensions 400x710x800 mm The open part of the bath is 120x210 mm Bath depth 500 mm Weight 60 kg Power consumption 3.5 kW.
Produced in: Tomsk
Circulation thermostat LT-208a
Circulation thermostat LT-208a
The LOIP LT-208a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 8 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 120x150/200 Overall dimensions, mm 180x335x420 Weight, kg 7.3
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-212b
Circulation thermostat LT-212b
The LOIP LT-212b modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a lean-to hinged lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 12 The working fluid is water, water-glycerin mixture, silicone oil. Open part of the bath / depth, mm 190x296/150 Overall dimensions, mm 355x335x370 Weight, kg 10.2
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-216a
Circulation thermostat LT-216a
The LOIP LT-216a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 16 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x42 0 Weight, kg 11.5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
VT5-2 Liquid thermostat
VT5-2 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external consumers of closed or open type. Pump for closed or open type thermostating systems. All-metal stamped tub with a volume of 5 liters and a depth of 200 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. The volume of the bath is 5 liters Overall dimensions 170x350x480 mm The open part of the bath is 75x35 mm Bath depth 200 mm Weight 11 kg Power consumption 2.2 kW
Produced in: Tomsk
VT10 Liquid thermostat
VT10 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external closed-type consumers. Feed pump for external closed-type thermostating systems. All-metal stamped tub with a volume of 10 liters and a depth of 200 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. The volume of the bath is 10 liters Overall dimensions 400x275x480 mm The open part of the bath is 120x200 mm Bath depth 200 mm Weight 14 kg Power consumption 2.2 kW
Produced in: Tomsk
Liquid thermostat VT-ro-02
Liquid thermostat VT-ro-02
Operating temperature range +15...+100 °C Metal bath with transparent walls. Basket for placing six cylinders for hydrometers. Stability and uniformity of temperature in the working bath is not worse than ± 0.01 ° C. The volume of the bath is 30 liters Overall dimensions 340x280x800 mm The open part of the bath is 120x210 mm Bath depth 500 mm The size of the viewing window is 190x480 mm Weight 25 kg Power consumption 2.2 kW
Produced in: Tomsk
Thermostat for determining viscosity LT-910
Thermostat for determining viscosity LT-910
Design features: Microprocessor-based PID controller; Multifunctional control knob; Efficient mixing system; Self-diagnosis system; Simple correction of internal temperature sensor readings; Two-point calibration; Built-in cooling coil; Technical specifications: Number of seats for viscometers 3 Temperature range - without external cooling, °C - with tap water cooling, °C - with cryostat cooling, °C (Current+10)...+150 (Tvods+5)...+150 0...+150 The error of setting the set temperature, ° C ± 0.02 Temperature maintenance error, ° C ± 0.01 Power consumption, W 1500 Overall dimensions, mm 380x235x560 Working depth, mm 300 Volume of working fluid, l 14 Weight of the device without liquid, kg 16
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Exposure device UER-03 (TU 26.51.70-003-63790925-2021 )
Exposure device UER-03 (TU 26.51.70-003-63790925-2021 )
1 supp.
The principle of operation of the device UER-03: The principle of operation of the device is based on the creation of equal conditions for all exposed samples during biotesting. It is achieved by rotating the cassette with the test culture samples of crustaceans installed in it around the central axis. Since the sample cassette is oriented obliquely, when it rotates, there is an active gas exchange between the surrounding air and water samples. As the result, test organisms in test tubes are provided with sufficient oxygen concentration in the medium during the entire exposure period. The rotation speed of the cassette is chosen so as not to have a stress effect on the crustaceans. The device operates in continuous mode and does not require additional intervention in the process of exposing the crustacean culture. The required conditions for temperature and light irradiation can be provided only when the device is installed in the climatostat. Used in techniques: - Methodology for determining the toxicity of water extracts from soils, sewage sludge and waste, drinking, sewage and natural water by the mortality of the test object (Daphnia magna Straus). MON F 14.1:2:4.12-06 / 16.1:2.3.3.9-06 FR.1.31.2009.06641. - Methodology for determining the toxicity index of nanopowders, products made of nanomaterials, nanopoints, waste and sewage sludge containing nanoparticles, according to the mortality of the test organism Daphnia magna Straus. FR.1.39.2010.09102 And it can also be used in other suitable techniques.
Evropolitest
Ivanteevka
Produced in: Moscow region
Cryothermostat liquid FT-311-25
Cryothermostat liquid FT-311-25
Technical specifications: Operating temperature range, °C -25...+100 Accuracy of temperature maintenance, °C ± 0.1 The discreteness of the temperature display, ° C 0.1 Cooling capacity at 20°C, W 520 Pump capacity in the discharge (suction) circuit, not less than, l/min 8,0 Volume of working fluid, l 10 The open part of the bath /depth, mm 190x130/200 Power supply, V/Hz 220/50 Power consumption, not more than 3.6 kW Overall dimensions, mm 430x665x460 Weight without working fluid, kg 40
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LAMPIX8 Portable instrument for real-time isothermal DNA amplification,  1 channel, 8×0,2 ml
LAMPIX8 Portable instrument for real-time isothermal DNA amplification, 1 channel, 8×0,2 ml
1 supp.
LAMPIX 8 uses the method of Loop-Mediated Isothermal Amplification of DNA and RNA (LAMP and RT-LAMP) for genetic analysis of any kind.
Key features.
  • Compact: supports 8 standard 200μL tubes in a single test run.
  • Portable:provides genetic testing in an on-site or mobile laboratory.
  • Fast: Result within 15 minutes after the start of the analysis.
  • Real-time: Detection of the results with our built-in software.
  • Open system: can work with any test kits with FAM / SYBR dyes for isothermal amplification.
  • Flexible: possibility to adjust settings for your research purposes.
LAMP TEST KITS: LAMP LYME KIT (Detection of the B.burgdorferi in ixodid ticks) *sensitivity from 50 copies of DNA. SARS-CoV-2 test (COVID-19).
Technical Specifications.
  • Excitation source 8 LEDs,
  • Excitation detection 8 photodiodes,
  • Number of Fluorophores 1 FAM/SYBR/EvaGreen,
  • Excitation wavelength 470 nm,
  • Detection range 510-530 nm,
  • Sample capacity 8 х 200 μl tubes,
  • Tube type separate tubes / strips with flat lid,
  • Operating temperature range 37˚C to 75˚C with 0.5˚C resolution,
  • Lid type heated lid,
  • Heated lid temperature range 37.0 ˚C to 75.0 ˚C with 0.5˚C resolution,
  • PC connection USB type С port,
  • Dimensions W × D × H 115 х 80 х 65 mm,
  • Weight 250 g,
  • Power 12 V / 18 W external power supply / power bank,
  • Software Operating system Win 7-10.
    Aivok
    Zelenograd
    Produced in: Moscow, Zelenograd