Search

12 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    All filters
    • 7
      Applying
    • Names
    • 5
      Manufacturer
    • 4
      Made in
    • 0
      Additional
      View:
      12 products
      Generator of cardiac-like signals GKS-2D
      Generator of cardiac-like signals GKS-2D
      Checking the performance of cardiographs, cardiac monitors and cardiac units of intensive care monitors; checking the general functionality and imitation of the patient (when checking stress systems, a cardioid signal is formed); checking the amplitude of the signal recording (a U-shaped signal is formed).
      Doza
      Zelenograd
      Produced in: Moscow
      High-frequency signal generator G4-232
      High-frequency signal generator G4-232
      A remote frequency converter with coaxial output extends the frequency range up to 37.5 GHz. The included coaxial-waveguide transitions and the ability to connect a small frequency converter directly to the user's device expand the scope of the device. The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz The frequency range at the output of the frequency converter is from 5 to 37.5 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter is from 0 to 13 dBm The basic error of setting the reference power level is ± (1.0 – 2.0) dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: LF from 1 Hz to 20 kHz RF from 10 Hz to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): LF from 1 Hz to 200 kHz RF from 10 Hz to 10000 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient: internal ± (0.15 M + 0.2)% external ± (0.20 M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
      Produced in: Moscow
      High-frequency signal generator G4-229
      High-frequency signal generator G4-229
      The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range (RF output) from 9 kHz to 6 GHz Frequency range (LF outputs) from 0.001 Hz to 30 MHz Frequency tuning discreteness (RF output) 1 Hz Frequency tuning discreteness (LF outputs) 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main RF output is from minus 120 to 13 dBm The range of setting the signal amplitude at a load of 50 ohms (LF outputs) from 0.01 to 5 V The basic error of setting the reference power level (RF output) ± (0.5 – 1.0) dB The basic error of setting the amplitude of sinusoidal signals (LF outputs) ± (3 – 15)% Instability of the signal power level for any 15-minute time interval (RF output) no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the basic error of setting the frequency deviation ± (10 – 20)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient (when operating from an internal signal source) ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
      Produced in: Moscow
      Rubidium reference generator RRS-002
      Rubidium reference generator RRS-002
      The device is made in a 19-inch rack design with a 4U stand. The rubidium reference generator RRS-002 provides up to 15 independent signal outputs with a frequency of 10 MHz (5 MHz). The device is designed for long-term uninterrupted operation both in round-the-clock continuous and in session mode. The high reliability of the generator is ensured by reserving the main generator blocks and, in case of malfunction of the active signal source, automatically switching to a backup one.
      Ruknar
      Nizhny Novgorod
      Produced in: Nizhny Novgorod
      High-frequency signal generator G4-230
      High-frequency signal generator G4-230
      The generator is capable of operating both autonomously and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 5 to 17.85 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 110 to 13 dBm The basic error of setting the reference power level is ± 1.0 dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: low frequency from 1 Hz to 20 kHz RFM from 10 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): low frequency from 1 Hz to 100 kHz RFM from 50 to 10000 kHz - the main error of the frequency deviation setting is ± (3 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the main error in setting the amplitude modulation coefficient: Internal ± (0.15M + 0.2)% External ± (0.20M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
      Produced in: Moscow
      High-frequency signal generator G4-227
      High-frequency signal generator G4-227
      The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 9 kHz to 6 GHz Frequency tuning discreteness of 1 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 10 to 13 dBm The basic error of setting the reference power level is ± (0.5 – 1.0) dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the main error of the frequency deviation setting is ± (20 – 25)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient ± (0.25 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 300 ns to 20 s - the range of the modulating pulse repetition period from 340 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 200 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 13 kg
      Produced in: Moscow
      High-frequency signal generator G4-235, G4-236
      High-frequency signal generator G4-235, G4-236
      Created on the basis of the G4-230 generator. Remote frequency converters extend the frequency ranges up to 53.57 GHz (G4-235) and up to 78.33 GHz (G4-236). The generators are capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz Frequency range at the output of the frequency converter (G4-235) from 37.5 to 53.57 GHz The frequency range at the output of the frequency converter (G4-236) is from 53.57 to 78.33 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter (G4-235) is from 0 to 13 dBm The range of setting the signal power level at the output of the frequency converter (G4-236) from 0 to 10 dBm The basic error of setting the reference power level is ± (1.0 – 2.5) dB Metrological characteristics of the generator in FM operation mode: - frequency range of the modulating signal from 1 Hz to 20 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 1 Hz to 200 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
      Produced in: Moscow