Multichannel digital measuring converter - recorder Ecofizika-500
Multichannel digital measuring converter - recorder Ecofizika-500
Ecofizika-500 is a multifunctional modern platform for building complex measuring systems. The developed software makes it possible to fully use the powerful hardware potential of the system in tasks requiring the use of complex computational algorithms. Ecofizika-500 is not just another multi-channel frontend designed to transfer unprocessed data to a computer; it is an independent measuring device capable of calculating a huge number of quantities in real time, storing them in its own memory and (or) issuing them to a telemetry channel. The device can be used, including in offline mode, as a data logger, which is very important when testing complex equipment that limits the presence of the operator. Ecofizika-500 has an approved type of measuring instrument and methodological support for measuring acoustic and vibrational quantities.
Produced in: Moscow
Acoustic ultrasonic flow meter Volga ML
Acoustic ultrasonic flow meter Volga ML
from 400 000 ₽
The flow meter is fully developed by Russian specialists in the field of acoustics, hydraulics and electronics, and is designed to measure the volumetric flow rate and volume of water in pipelines, mainly medium and large, under pressure, non-pressure and combined (pressure-free) flow modes. The flowmeter is based on ultrasonic "time-pulse" multipath technology for measuring the flow velocity in the measuring range. In addition, depth sensors (primary transducers) - hydrostatic, radar contactless, ultrasonic underwater or ultrasonic contactless - are used to measure the flow in water ducts with a combined or non-pressure flow mode. In the presence of deposits affecting the shape and area of the live section of the flow, sediment level sensors are used. Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Inset and overhead primary converters from the inside allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 15000 mm The Volga ML acoustic ultrasonic flowmeter is registered as a type of measuring instrument in the Federal Information Fund for Ensuring the Uniformity of Measurements for No. 78414-20 (MP 2550-0361-2019). The Volga ML acoustic ultrasonic flow meter has been recognized as the winner in the nomination Best Technology of the International Environmental Award EWA Award 2020.
Produced in: Moscow
Non-pressure hybrid flow meter-counter Volga Triton
Non-pressure hybrid flow meter-counter Volga Triton
from 300 000 ₽
The Volga Triton pressure-free hybrid flow meter is designed to measure the volumetric flow of liquid in water ducts with a pressure-free and combined pressure-free flow mode. The submerged primary speed converter operates on the basis of the Doppler effect, emitting an ultrasonic signal towards the flow and receiving an echo reflected from particles in the flow with a frequency different from the frequency of the emitted signal. This frequency shift is called the "Doppler Shift" and it is proportional to the flow rate. A non-contact ultrasonic primary converter VBN-DG-01 or any other third-party liquid level converter with a unified current output of 4-20 mA can be used as a depth meter: radar, hydrostatic or ultrasonic. The volumetric flow rate is determined both by the "area-speed" method and by MI2220-2013, depending on hydraulic conditions. In non-contact (radar) mode, the Volga Triton flowmeter is designed to measure the volumetric flow rate of a liquid in a non-pressurized flow mode. The flow meter can be used as part of waste water metering units in non-pressure (gravity) sewage systems, open irrigation and reclamation channels, open or underground derivational non-pressure water pipelines of hydropower facilities, diverting supply and recirculation water pipelines of thermal power and other hydraulic structures with a non-pressure flow regime. The measurement technology is based on a non-contact radar method for measuring surface flow velocity and a non-contact ultrasonic/radar method for measuring water level. As a water level meter, both the proprietary ultrasonic level sensor BP-G-01 and third-party sensors connected via unified digital or analog interfaces, for example, VEGAPLUS, can be used. The pressure-free hybrid flow meter "Volga Triton" became the winner of the International Environmental Award EWA Award 2021 in the nomination Best technology. Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters VBN-DS-01 Primary speed converter for medium and large water pipelines VBN-DS-02 Combined primary speed and depth converter for medium and small aqueducts VBN-DS-03 is a combined low-profile primary speed and depth converter for small aqueducts. VBN-DG-01 - contactless ultrasonic primary transducer - depth meter Pipe sizes Du, mm: 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
AD-42IP Acoustic Flaw Detector
AD-42IP Acoustic Flaw Detector
from 383 500 ₽
It is especially effective for use in products made of composite materials (including with honeycomb filler). Distinctive features: The AD-42 IP is a compact acoustic system sensitive to changes in mechanical impedance caused by product defects. The indication of the device indicates that there are voids, non-adhesives, delaminations or changes in the structure of composite materials (including with honeycomb filler and laminated plastics) under the sensor. The device is used to monitor various materials and their combinations. The energy consumption of the unit is low because the converter is switched on when the sensor is placed on the monitored product. Being light enough, the device allows you to perform monitoring in hard-to-reach places or in confined spaces. The results of the control can be stored in the built-in non-volatile memory and transferred to a PC. Converters Options: - 3 types of converters for various tasks Emitters: - 1 or 2 on each converter Switching-on: - The converters are switched on when they are placed on a controlled object. Technical characteristics: Weight, kg: 0.73 Dimensions, mm: 210x150x70 Power supply: 4 AA batteries Work without recharging the battery, h: 8 Battery discharge visual indication The defect alarm is visual on the converter and audible on the instrument panel (or) in headphones.
Produced in: Moscow
AD-64M Acoustic Impedance Flaw Detector
AD-64M Acoustic Impedance Flaw Detector
from 715 855 ₽
Control methods: Impedance method (IM) and free oscillation method (MSC) Distinctive features: - A wide range of controlled materials: from steel to foam and structures with soft external and internal elements - Application of two complementary control methods - One-way access - Dry contact of the transducers with the controlled object - Visual representation of information - The ability to memorize and reproduce the setting modes, which excludes the use of control samples at the workplace Technical specifications: The minimum area of the detected defect, cm2: 1 The depth of detected defects in fiberglass, mm: up to 12...15 Light and sound signaling of defects Number of measurements per second: 15 Weight, kg: 1 Self-powered by batteries Continuous battery life, h: 8 Operating temperature range, °C: -10...40