      Automatic device for determining the flash point in a closed crucible TVZ-LAB-12
      Automatic device for determining the flash point in a closed crucible TVZ-LAB-12
      The TVZ-LAB-12 automatic apparatus is designed to determine the flash point in a closed crucible by the Pensky-Martens method in accordance with GOST R EN ISO 2719-2008, GOST R 54279-2010, GOST ISO 2719-2013, GOST 6356-75, GOST 9287-59, ISO 2719, ASTM D 93 (methods A, B and C). The device is designed taking into account all the requirements of the new GOST R EN ISO 2719-2008 for testing. Extensive software configuration options and a special design of the device ignition device allows you to obtain test results with high convergence in GSO even when using electric ignition according to GOST R EN ISO 2719-2008. Technical specifications: Flash temperature measurement range 0 ... 400°C Heating speed 0.5 ... 20°/min The range of setting the ignition period, 0.5 ... 10°C Igniting gas flame, electric spiral Flash sensor Thermocouple with low mass The rotation speed of the agitator is 30 ... 250 rpm Power consumption from AC 220V, no more than 600 watts Overall dimensions 465x340x390 mm The weight of the device is 15 kg
      LOIP
      Saint Petersburg
      Produced in: Saint Petersburg
      Automatic apparatus for determining the flash point in an open crucible TVO-LAB-12
      Automatic apparatus for determining the flash point in an open crucible TVO-LAB-12
      Technical specifications: Flash temperature measurement range 0...400°C Heating speed 0.5...20°C/min The ignition period is 0.5...10°C Igniting a gas flame Flash/ignition ionization sensor Power consumption from AC 220V, no more than 700 watts Overall dimensions 405x340x265 mm The weight of the device is 12 kg
      LOIP
      Saint Petersburg
      Produced in: Saint Petersburg
      Apparatus for determining the flash point in a closed crucible TVZ-LAB-01
      Apparatus for determining the flash point in a closed crucible TVZ-LAB-01
      The analyzer automatically heats the sample crucible and moves the test flame. The flash moment is set visually and recorded by pressing the "STOP" button, while the flash temperature is displayed on the display. Technical specifications: Flash temperature measurement range (with crucible cooling), °C from +40 to +400* The heating rate of the crucible with the sample, °C/min 0..20 Igniting a gas flame The speed of the stirrer, rpm 30...240 Power consumption from AC 220 V, no more, 600 W Overall dimensions of the device, not more than 350x250x280 mm Weight of the device, not more than, kg 8
      LOIP
      Saint Petersburg
      Produced in: Saint Petersburg
      Apparatus for determining the flash point in an open crucible TVO-LAB-01
      Apparatus for determining the flash point in an open crucible TVO-LAB-01
      The analyzer automatically heats the sample crucible and moves the test flame. The flash moment is set visually and recorded by pressing the "STOP" button, while the flash temperature is displayed on the display. Technical specifications: Flash temperature measurement range, °C from +79 to +400 Heating speed, °C/min 2.0...20.0 Power consumption from AC 220 V, no more, 800 W Overall dimensions of the device, not more than, mm 400x360x470 Weight of the device, not more than, kg 14 Igniting a gas flame
      LOIP
      Saint Petersburg
      Produced in: Saint Petersburg