Search

2 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 2
    Applying
  • Names
  • 1
    Manufacturer
  • 1
    Made in
  • 1
    Additional
View:
2 products
PipeScope 60-170 Portable Rapid Diagnostics System for Drill Pipes
PipeScope 60-170 Portable Rapid Diagnostics System for Drill Pipes
Technical characteristics of PipeScope 60-170 Pipe inspection time in the installation is no more than 30 seconds The diameter range of controlled pipes is 60 mm – 170 mm The range of wall thicknesses of controlled pipes is up to 20 mm The length of the controlled pipes is 1..13 m The maximum time of continuous operation per day is up to 24 hours Rated power supply voltage is 50 Hz, 220 V The working gap between the sensor and the control object is up to 0.5 mm Operating temperature range is -40 °C... +40 °C The number of measuring channels for searching for defects using the magnetic flux scattering method is up to 128* The number of measuring channels for defect detection and thickness measurement using the flow density measurement method is up to 96* Pipe diameter measurement error 0.05% The measurement error of the length of the controlled pipe is 10 cm The possibility of demagnetization of the pipe after control in automatic and manual modes is availiable The coverage of the continuity of control along the perimeter of the pipe is 100% The changeover time of the installation to another BT standard size is no more than 30 minutes. The speed of movement of the flaw detector trolley through the pipe is from 0 to 0.9 m/s Power consumption is up to 1 kW Installation weight  Trolley with basket — no more than 11 kg Magnetization coil — no more than 10 kg Air lift — no more than 72 kg Minimum size of detectable defects In accordance with DS-1 Minimum signal-to-noise ratio for drilling with a diameter of 1.6 mm In accordance with DS-1 The error in determining the linear coordinate of the defect is not more than 5 cm The error in determining the angular coordinate of the defect is no more than 4 degrees ° Installation control complies with the following standards in terms of its characteristics: API Spec 5D, API RP7G, DS- 1 Overall size and weight of PipeScope 60 — 170 Ultra Pro in transport containers without SOP and without pneumatic lifts 600 mm X 600 mm X 600 mm / 32 kg Overall size and weight of the air lift in a transport container is 1300 mm X 300 mm X 300 mm / 72 kg Overall size and weight of the SOP in a transport container is 1900 mm X 210 mm X 210 mm / 60 kg
Oktanta
Saint Petersburg
Produced in: Saint Petersburg