Search

6 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    All filters
    • 1
      Applying
    • Names
    • 1
      Manufacturer
    • 1
      Made in
    • 0
      Additional
      View:
      6 products
      MARK-603/1
      MARK-603/1
      Measurement of electrical conductivity (UEP, UEP20, UEP25), equivalent salinity according to NaCl, total salinity (TDS) and temperature of water and aqueous solutions in various industries and national economy. Control of chemical water treatment at thermal power facilities. Control of surface waters at a depth of up to 20 meters. Control of distilled water according to GOST 58144-2018 "Distilled water. Technical conditions". Control according to GOST 26423-85 "Soils. Methods for determining the specific electrical conductivity, pH and dense residue of water extract". 24-month warranty for deliveries across the Russian Federation IP65 The compact sealed device is reliably protected from dust and moisture Electronic notebook Ability to record up to 100 measurement groups in User-named folders Stainless steel Submersible sensor The ability to measure at a depth of up to 20m Graphic indicator with backlight Indication of readings in a user-friendly format Low power consumption Up to 600 hours of operation from a set of AA type elements
      VZOR
      Nizhny Novgorod
      Produced in: Nizhny Novgorod
      conductometer MARK® 602
      conductometer MARK® 602
      Measurement of electrical conductivity (UEP, UEP25) and salinity of aqueous media, including "ultrapure". Control of water-chemical regimes at thermal and nuclear power facilities. Specialized water treatment.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Double automatic thermal compensation. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
      VZOR
      Nizhny Novgorod
      Produced in: Nizhny Novgorod
      conductometer MARK® 1102
      conductometer MARK® 1102
      Measurement of specific electrical conductivity (UEP, UEP25) and mass fraction (C) of solutes (NaCl, NaOH, HNO3, H2SO4, HCl) in water. Control of water-chemical regimes at thermal and nuclear power facilities.Contactless inductive sensor resistant to aggressive environments | Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings. Submersible, trunk, flow fittings |
      VZOR
      Nizhny Novgorod
      Produced in: Nizhny Novgorod
      conductometer MARK® 602 MP
      conductometer MARK® 602 MP
      Measurement of electrical conductivity (UEP, UEP25) and salinity of aqueous media, including "ultrapure", in the main and flow modes. Control of water-chemical regimes at thermal and nuclear power facilities, including control of cooling water suction in the turbine condenser.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Double automatic thermal compensation. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings.
      VZOR
      Nizhny Novgorod
      Produced in: Nizhny Novgorod
      MARK-603
      MARK-603
      Measurement of electrical conductivity (UEP, UEP25), equivalent salinity and temperature of water and aqueous solutions, including deionized and "ultrapure". Operational control of water-chemical regimes at thermal power facilities. Control of electrical conductivity of water for laboratory analysis of 1, 2 degrees of purity according to GOST 52501-2005. 24-month warranty for deliveries across the Russian Federation Double automatic temperature compensation (ATC) Allows high-precision measurements of the conductivity of "ultrapure" water Selection of the coefficient of thermal compensation at the request of the User Stainless steel flow-immersion sensor Does not require calibration. The sensor design ensures the stability of the permanent cell Electronic notebook Ability to record up to 500 measurement groups in User-named folders Self-diagnosis Ion exchange column with sample current switch IP65 The compact sealed device is reliably protected from dust and moisture USB port, software included Graphic indicator with backlight Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
      VZOR
      Nizhny Novgorod
      Produced in: Nizhny Novgorod
      conductometer MARK® 602 T
      conductometer MARK® 602 T
      Measurement in the main and flow modes of electrical conductivity (UEP, UEP25, UEP20), electrical resistivity (UES, UES25, UES20), salinity and temperature of aqueous media, including "ultrapure". Control of water-chemical regimes at thermal and nuclear power facilities. Two independent measurement channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Medium temperature up to 130 ° C, pressure up to 1.6 MPa. Double automatic thermal compensation in the range from 0 to 100 °C. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 1000 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Three relays of "dry" contacts in each channel. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture.
      VZOR
      Nizhny Novgorod
      Produced in: Nizhny Novgorod