Search

51 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 2
    Applying
  • Names
  • 3
    Manufacturer
  • 4
    Made in
  • 2
    Additional
View:
51 products
VEGA ProVac 1500 high-vacuum turbomolecular pump
VEGA ProVac 1500 high-vacuum turbomolecular pump
The complex includes: VEGA ProVac 1500 turbomolecular high vacuum pump; frequency converter; set of mounting parts; operation manual. For connection to the pre-vacuum pumping system, the pump is equipped with an ISO-KF40 exhaust flange. Pump cooling is combined. Based on the operating conditions, the complex can work both with forced air cooling and with water cooling. The working orientation in space is vertical.
Produced in: Vladimir
2NVBM-500/12000 Booster High Vacuum Pump
2NVBM-500/12000 Booster High Vacuum Pump
The 2NVBM-500/12000 booster pump consists of housings, a steam pipe, a trap and a heater. The required effective speed of action of the pre-vacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the booster pump is not less than 100 l/s. The maximum residual pressure of the 2NVBM-500/12000 pump measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6 × 10-4Pa (5 × 10-6 mm Hg). The pressure of the cooling water at the inlet to the pump 2NVBM-500/12000 should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2). The discharge from the pump should be free with a jet break. Cooling water consumption 1200 l/h. The total amount of working fluid for the 2NVBM-500/12000 pump is 65 liters, the level of working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1 · 10-2 to 1 · 10-1 mm Hg). The operating mode of the pump in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
Вакуумный мембранный насос PL.HM02.02.8 Праймлаб
Вакуумный мембранный насос PL.HM02.02.8 Праймлаб
from 185 000 ₽
1 supp.
The vacuum membrane pump PL.HM02.02.8 helps speed up the laboratory process by quickly pumping vapors and gases and creating a vacuum. Suitable for working with flammable, toxic and chemically active substances. A special feature of the PL.HM02.02.8 Primelab pump is the ability to customize it for different production tasks: • With a parallel connection, the pumping speed is 76 l/min with a maximum residual pressure of 45 mbar. • With independent connection, 38 l/min at a maximum residual pressure of 45 mbar. • When chambers are connected in series, the flow rate is 38 l/min with a maximum residual pressure of 8 mbar.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
3VVN1-25 Water ring vacuum pump
3VVN1-25 Water ring vacuum pump
The 3VVN1-25(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-25(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006
Produced in: Kazan
Vacuum turbomolecular complex KW-50
Vacuum turbomolecular complex KW-50
The complex includes: single-flow turbomolecular vacuum pump VGTN-50; frequency converter; set of mounting parts; operation manual. For connection to the pre-vacuum pumping system, the pump is equipped with an ISO-KF16 exhaust flange. Pump cooling is combined. Based on the operating conditions, the complex can work both with forced air cooling and with water cooling. The working orientation in space is arbitrary. One of the key features of the pump is that a breakthrough of the atmosphere is allowed. This became possible thanks to the manufacture of a turbine from a solid billet and a special, rigid design of the bearing assembly.
Produced in: Vladimir
NVDM-100 High-vacuum Diffusion Pump
NVDM-100 High-vacuum Diffusion Pump
The operation of the NVDM-100 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-100 diffusion pump is a cap with a cooling tube soldered onto it with fittings. The open heater of the NVDM-100 diffusion pump is a metal housing with a ceramic base laid in it with a heating element made in the form of a spiral of nichrome wire. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6×10-2 to 13.3 Pa (from 5×10-4 to 1×10-1 mm Hg). Water at the inlet to the cooling systems of the housing and oil reflector should be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 4˚C to plus 25˚C. The recommended cooling water consumption is 35+5 l/h and is regulated by the outlet water temperature, which should not exceed plus 40˚C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 35 Pa (0.263 mm Hg). The level of the working fluid during operation, at which the parameters of the NVDM-100 diffusion pump are provided, must correspond to min 7mm, max 11mm. The volume of the filled working fluid is 0.07/
Produced in: Kazan
NVDM-250 High vacuum Diffusion Pump
NVDM-250 High vacuum Diffusion Pump
The operation of the NVDM-250 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-250 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-250 open-type diffusion pump heater is a metal housing with a ceramic base laid in it with a heating element in the form of a spiral made of nichrome wire. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6 × 10-2 to 13.3 Pa (from 5 ×10-4 to 1 ×10-1 mmHg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 4°C to plus 25°C. The recommended cooling water consumption is 100+15 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mmHg) The level of the working fluid during operation, at which the parameters of the pump NVDM-250 are provided, must correspond to min 8mm, max 13mm. The volume of the filled working fluid is 0.55 l
Produced in: Kazan
2NVR-5DG Vacuum pump
2NVR-5DG Vacuum pump
The 2NVR-5DG UM4 pump is manufactured in the climatic version of UM 4 (i.e. for moderate climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). Electricity grid must meet the requrimemnts of GOST 13109-97. The 2NVR-5DG vacuum rotary vane pump meets the requirements of technical specifications TU 3648-006-00218526-2002. The 2NVR-5DG pump is refueled with VACMA OIL 100 working fluid. Monitoring of the level of the working fluid is ensured by the oil indicator, replenishment is neede when the level of the working fluid is below the minimum level of the oil indicator.
Produced in: Kazan
High-vacuum turbomolecular pump VEGA ProVac 2000
High-vacuum turbomolecular pump VEGA ProVac 2000
The complex includes: VEGA ProVac 2000 turbomolecular high vacuum pump; frequency converter; a set of mounting parts. For connection to the pre-vacuum pumping system, the pump is equipped with an ISO-KF40 exhaust flange. Pump cooling is combined. Based on the operating conditions, the complex can work both with forced air cooling and with water cooling. The working orientation in space is vertical.
Produced in: Vladimir
2NVR-250D Vacuum rotary vane pump
2NVR-250D Vacuum rotary vane pump
the 2NVR-250D vacuum pump is manufactured in the climatic version of UM 4 (i.e. for moderate climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). Electricity grid must meet the requrimemnts of GOST 13109-97. The 2NVR-250D vacuum rotary vane pump meets the requirements of technical specifications TU 3648-006-00218526-2002. The 2NVR-250D pump is refueled with VACMA OIL 100 power fluid. The level of the working fluid is monitored by the oil indicator, replenishment is needed when the level of the power fluid is below the minimum level of the oil indicator.
Produced in: Kazan
Vacuum membrane pump PL.HM03.01.60 Primelab
Vacuum membrane pump PL.HM03.01.60 Primelab
from 90 000 ₽
1 supp.
The PL.HM03.01.60 Primelab vacuum diaphragm pump is suitable for creating a vacuum up to 60 mbar and a flow rate of 38 l/min. It has a dry design that does not require lubrication. Quite easy to use and does not create any inconvenience during operation. Its noise level does not exceed 75 dB. With a light weight of 6.9 kg, it has compact dimensions (289.5x160x200 mm), allowing the pump to be integrated into an already equipped space. Complies with IP20 protection class. The PL.HM03.01.60 Primelab vacuum diaphragm pump is supplied in the following package: vacuum pump, cable, instructions, passport, packaging (vacuum regulator and spare parts are not included in the kit and must be ordered separately). Warranty and post-warranty service is available in Russia.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
NVR-4,5D Plate-rotary vacuum pump
NVR-4,5D Plate-rotary vacuum pump
Pumping out steam-gas mixtures is allowed only when the gas-ballast device is open. The NVR-4,5D vacuum plate-rotary pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-006-00218526-2002, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity grid must meet the requirements of GOST 13109-97.
Produced in: Kazan